scholarly journals Difference Between Dormant Conduction Sites Revealed by Adenosine Triphosphate Provocation and Unipolar Pace-Capture Sites Along the Ablation Line After Pulmonary Vein Isolation

2016 ◽  
Vol 57 (1) ◽  
pp. 25-29 ◽  
Author(s):  
Rikitake Kogawa ◽  
Yasuo Okumura ◽  
Ichiro Watanabe ◽  
Kazumasa Sonoda ◽  
Naoko Sasaki ◽  
...  
2015 ◽  
Vol 26 (10) ◽  
pp. 1075-1080 ◽  
Author(s):  
BENJAMIN SCHAEFFER ◽  
STEPHAN WILLEMS ◽  
ARIAN SULTAN ◽  
BORIS A. HOFFMANN ◽  
JAKOB LÜKER ◽  
...  

2015 ◽  
Vol 26 (10) ◽  
pp. 1069-1074 ◽  
Author(s):  
SHINSUKE MIYAZAKI ◽  
HIROSHI TANIGUCHI ◽  
HIROAKI NAKAMURA ◽  
HITOSHI HACHIYA ◽  
NOBORU ICHIHARA ◽  
...  

2020 ◽  
Author(s):  
Hai yang Xie ◽  
Xiao gang Guo ◽  
Jian du Yang ◽  
Hui qiang Wei ◽  
Bin Luo ◽  
...  

Heart Rhythm ◽  
2012 ◽  
Vol 9 (9) ◽  
pp. 1583
Author(s):  
Daniel Steven ◽  
Arian Sultan ◽  
Jakob Lueker ◽  
Boris Hoffmann ◽  
Jana Nuehrich ◽  
...  

2013 ◽  
Vol 62 (1) ◽  
pp. 44-50 ◽  
Author(s):  
Daniel Steven ◽  
Arian Sultan ◽  
Vivek Reddy ◽  
Jakob Luker ◽  
Manuel Altenburg ◽  
...  

2018 ◽  
Vol 2018 ◽  
pp. 1-5
Author(s):  
Yu-Chuan Wang ◽  
Bo Huang ◽  
Kang Li ◽  
Peng-Kang He ◽  
Er-Dong Chen ◽  
...  

Objectives. To identify optimal predefined criteria (OPC) for filters of the VisiTag™ module in the CARTO 3 system during pulmonary vein isolation (PVI). Methods. Thirty patients with atrial fibrillation (AF) who experienced PVI first were enrolled. PVI was accomplished by using a Thermocool SmartTouch catheter. Ablation lesions were tagged automatically as soon as predefined criteria of the VisiTag™ module were met. OPC should be that ablation with the setting resulting in the conduction gap (CG) as few as possible, while contiguous encircling ablation line (CEAL) without the tag gap (TG) on the 3D anatomic model as much as possible. Result(s). When ablation with parameter setting is being catheter movement with a 3 mm distance limit for at least 20 s and force over time (FOT) being off, there were 60 CEAL without TG on the 3D anatomic model. However, 26 CGs were found. After changing FOT setting to be a minimal force of 5 g with 50% stability time, 22 TGs were displayed. Of them, 20 TGs were accompanied by CGs. On reablation at sites of TG with changed parameter setting, 18 CGs were eliminated when 20 TGs disappeared. When reablation with FOT is being a minimal force of 10 g with 50% stability time, 6 remaining CGs were eliminated. However, there was no CEAL. With a mean of follow-up 10.93 months, 2 patients with persistent AF suffered AF recurrence. Conclusion. A 3 mm distance limit for at least 20 s and FOT being a minimal force of 5 g with 50% stability time might be OPC for the VisiTag™ module.


2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
M J Mulder ◽  
M J B Kemme ◽  
M J W Gotte ◽  
H A Hauer ◽  
G J M Tahapary ◽  
...  

Abstract Background Pulmonary vein isolation (PVI) is not always achieved after initial encircling of the pulmonary veins (PVs). Additional touch-up lesions are frequently required to close residual gaps, which may occur both in the initial ablation line and on the intervenous carina. Purpose We aimed to identify determinants and prognostic implications of residual gaps during index radiofrequency PVI. Methods Two hundred fourteen AF (atrial fibrillation) patients (57% paroxysmal, 61% male, mean age 62±9 years) undergoing contact force-guided PVI were studied. Residual gaps after initial encircling of the PVs were targeted for additional ablation and were classified as either gap ablation in the initial WACA (wide-area circumferential ablation) circle or carina ablation, depending on the site of earliest activation. After a waiting period of at least 30 minutes, persistence of PVI was tested through administration of 9–18 mg intravenous adenosine. Pre-procedural cardiac computed tomography imaging was used to assess left atrial and PV anatomy. Carina width was defined as the distance between ipsilateral superior and inferior PV ostia. Ablation procedures were analyzed to define the perimeter of the WACA circle. Results One hundred thirty-three patients (62%) required additional ablation lesions beyond the initial WACA circles to achieve complete PVI. Gap ablation was required in the left WACA circle in 34 patients (16%) and in the right WACA circle in 49 patients (23%). Left and right carina ablation were required in 50 (23%) and 83 (39%) patients, respectively. Multivariate analyses identified carina width and perimeter of the WACA circle as independent predictors of requirement for ipsilateral carina ablation, whereas paroxysmal AF and the perimeter of the WACA circle were associated with requirement of gap ablation in the initial WACA circle. Recurrence of atrial tachyarrhythmias was documented in 73 patients (34%) at 12 months follow-up. Kaplan–Meier survival analyses demonstrated a significantly higher rate of recurrence in patients with one or more residual gaps in the ablation line (43% vs. 30%, p=0.019, figure A), whereas no significant difference between patients with and without requirement of carina ablation was found (38% and 29%, respectively; p=0.111, figure B). Kaplan-Meier survival analyses Conclusion Residual gaps in the initial WACA circle were associated with increased AF recurrence rate after PVI, whereas residual gaps on the intervenous carina had no statistically significant impact on AF recurrence. Consequently, gaps occurring in the ablation line and gaps on the intervenous carina may represent different mechanisms and may have different prognostic implications.


Sign in / Sign up

Export Citation Format

Share Document