scholarly journals Response to Comment on the study titled “Analysis of indium in workplace air by electrothermal atomic absorption spectrometry”

Author(s):  
Yoko Eitaki ◽  
Makiko Nakano ◽  
Kazuyuki Omae ◽  
Toru Takebayashi
2021 ◽  
Vol 4 (02) ◽  
pp. 47-59
Author(s):  
Somayeh Mirza Mirza ◽  
Azadeh Yahya Meymandi

The exposure of lead in workplace air and human workers of battery manufacturing factory was evaluated determined by nanotechnology since 2019-2020. Human whole blood (HWB) for subject and healthy peoples (25-55, Men, 40 N) and workplace air (40N) was prepared based on NIOSH sampling. 10 mL of HWB samples added to 20 mg of mixture ionic liquid/ ligand ([HMIM][PF6]/APDC) modified on graphene oxide nanostructures(GONs) at pH=6. After sonication, the lead ions separated/extracted by dispersive ionic liquid solid phase micro extraction (DIL-SPME) and determined by flame atomic absorption spectrometry (F-AAS). All air samples in workplace were analyzed based on NIOSH process. The results showed us the negative correlation between Pb concentration in human blood subject and healthy peoples (r=0.24). The range concentrations of lead in human subject, healthy peoples and workplace air were obtained 193.4-543.7 µg L-1, 85.6-175.9 µgL-1 and 44.7-81.5 µgm-3, respectively. The LOD, linear rang, enrichment factor(EF) and RSD% were achieved 1.25 µg L-1, 5.0- 310 µg L-1, 19.6 and less than 5% by procedure. The method was validated by standard reference material (SRM), the electrothermal atomic absorption spectrometry (ET-AAS) and ICP-MS analyzer for human samples.