The Novel Angiolink Staple-mediated Vascular Closure Device

2004 ◽  
Vol 1 (1) ◽  
pp. 91-92
Author(s):  
David E Allie ◽  
Chris J Herbert ◽  
Craig M Walker

2006 ◽  
Vol 2 (1) ◽  
pp. 1
Author(s):  
David E Allie ◽  
Chris J Hebert ◽  
Craig M Walker ◽  
◽  
◽  
...  

2019 ◽  
Vol 74 (13) ◽  
pp. B793
Author(s):  
Livia L. Gheorghe ◽  
Jorn Brouwer ◽  
Alejandro Gutierrez-Barrios ◽  
Martin Swaans ◽  
Jurrien Ten Berg

2021 ◽  
pp. 112972982110128
Author(s):  
Annette Thurner ◽  
Anjana Heuer ◽  
Anne Marie Augustin ◽  
Carsten Gietzen ◽  
Thorsten A Bley ◽  
...  

Background: This retrospective study investigates the efficacy and safety of the novel Celt ACD® vascular closure device (VCD) following antegrade and retrograde common femoral artery (CFA) punctures for the treatment of peripheral artery disease in a challenging patient collective (e.g. calcifications, obesity, and anticoagulation). Methods: A total of 208 VCDs (i.e. 100 antegrade and 108 retrograde) were deployed between October 2019 and December 2020 in a tertiary referral interventional radiology department. Fifty-two devices were undersized in relation to the introducer sheath (up to 2 Fr). Technical success and VCD related complications were evaluated in the immediate post procedure period and the following 24 h clinically. In 68% of cases, additional duplex ultrasound was performed prior to discharge. Results: The overall technical success rate was 97%. Technical failures following antegrade approach were due to a too acute access angle (⩾60°), rendering it impossible to pass the applicator tip through the sheath lumen. A subgroup analysis of technical success pinpoints severe calcification as another key limiting factor in VCD use ( p = 0.004). Comparing equally sized with undersized device selection ( p = 0.196), direction of approach ( p = 0.265), and body mass index ( p = 0.184) proved to be insignificant. Five (2%, 5/208) major complications occurred: Four antegrade (i.e. one false aneurysm, one vessel laceration with retroperitoneal hemorrhage, two device migrations; 4%, 4/100) and one following retrograde access (i.e. >6 cm hematoma, 1%, 1/108)). Complications were successfully managed with manual compression or interventional procedures. Conclusions: The novel clip-based VCD proved to be effective with a low VCD related complication rate.


VASA ◽  
2004 ◽  
Vol 33 (2) ◽  
pp. 78-81 ◽  
Author(s):  
Thalhammer ◽  
Aschwanden ◽  
Jeanneret ◽  
Labs ◽  
Jäger

Background: Haemostatic puncture closure devices for rapid and effective hemostasis after arterial catheterisation are a comfortable alternative to manual compression. Implanting a collagen plug against the vessel wall may become responsible for other kind of vascular injuries i.e. thrombotic or stenotic lesions and peripheral embolisation. The aim of this paper is to report our clinically relevant vascular complications after Angio-Seal® and to discuss the results in the light of the current literature. Patients and methods: We report the symptomatic vascular complications in 17 of 7376 patients undergoing diagnostic or therapeutic catheterisation between May 2000 and March 2003 at the University Hospital Basel. Results: Most patients presented with ischaemic symptoms, arterial stenoses or occlusions and thrombotic lesions (n = 14), whereas pseudoaneurysms were extremely rare (n = 3). Most patients with ischaemic lesions underwent vascular surgery and all patients with a pseudoaneurysm were successfully treated by ultrasound-guided compression. Conclusions: Severe vascular complications after Angio-Seal® are rare, consistent with the current literature. There may be a shift from pseudoaneurysms to ischaemic lesions.


VASA ◽  
2013 ◽  
Vol 42 (2) ◽  
pp. 144-148 ◽  
Author(s):  
Daniel Maxien ◽  
Barbara Behrends ◽  
Karla M. Eberhardt ◽  
Tobias Saam ◽  
Sven F. Thieme ◽  
...  

2020 ◽  
Author(s):  
A. El-Sayed Ahmad ◽  
S. Salamate ◽  
M. Amer ◽  
S. Sirat ◽  
Ö. Akhavuz ◽  
...  

2011 ◽  
Vol 77 (7) ◽  
pp. 1079-1085 ◽  
Author(s):  
Israel M. Barbash ◽  
Christina E. Saikus ◽  
Kanishka Ratnayaka ◽  
Anthony Z. Faranesh ◽  
Ozgur Kocaturk ◽  
...  

1995 ◽  
Vol 2 (3) ◽  
pp. 289-296 ◽  
Author(s):  
Michel Henry ◽  
Max Amor ◽  
Mohamed Allaoui ◽  
Olivier Tricoche

Purpose: Given the increasing number of percutaneously applied endovascular therapies, the incidence of access-related vascular complications can be expected to rise, particularly in association with those techniques requiring large sheaths or anticoagulation. The need exists for a safe, easy to use, and effective hemostatic technique to replace the labor-intensive method of manual compression. Methods: A bioabsorbable, sheath-delivered vascular closure device (Angio-Seal™) has been developed that deposits a small collagen plug within the arterial wall to mechanically seal the puncture defect. An anchor connected by suture to the plug is first deployed in the arterial lumen and pulled flush against the interior arterial wall to guard against intraluminal deposition of the collagen. Results: The Angio-Seal device was deployed successfully in 80 (96%) of 83 attempts involving common femoral arteries accessed for peripheral angioplasty (n = 30), coronary angiography (n = 30), and coronary angioplasty (n = 16). Three popliteal artery access sites and one femoropopliteal bypass graft were also treated. Hemostasis was immediate in 78 cases (98%); 2 sites required a 5-minute manual compression to effect a secure seal. Three devices failed to deploy, and manual pressure was used to close the puncture. Nondeployment did not cause any sequelae, and no complications were encountered with the technique. Conclusions: This novel vascular closure device is quick (< 1 minute application time) and simple to use, providing a positive seal of common femoral artery puncture sites for both peripheral and coronary interventions. It appears to be a reliable alternative to standard manual hemostasis.


Sign in / Sign up

Export Citation Format

Share Document