scholarly journals Effect of Mechanical Cycling on Screw Torque in External Hexagon Implants with and without Platform Switching

2015 ◽  
Vol 26 (3) ◽  
pp. 284-287 ◽  
Author(s):  
Bruno Andrade Cantharino de Carvalho ◽  
Eduardo Vedovatto ◽  
Paulo Sérgio Perri de Carvalho ◽  
José Vitor Quinelli Mazaro ◽  
Rosse Mary Falcón-Antenucci

This in vitro study evaluated the effect of mechanical cycling on the torque of retaining screw in external hexagon implants with platform switching (PS), regular platform (RP) and wide platform (WP). A total of 30 specimens were equally divided into 3 groups: PS, PR and WP. Each specimen was prepared with implants: 3.75 x 10 mm for RP group and 5.0x10 mm for PS and WP groups and its respective abutment with 32 Ncm torque. All groups were subjected to 106 cycles with 100 N (corresponding to about 40 months of chewing). The results were obtained with the reverse torque of each specimen and data were evaluated using ANOVA and Tukey test (p<0.05). The PS group showed statistically significant difference in screw removal torque (30.06±5.42) compared with RP (23.75±2.76) and WP (21.32±3.53) (p<0.05) groups; the RP and WP groups showed no statistically significant difference between them. It was concluded that the PS group showed higher reverse torque value, suggesting lower susceptibility of the abutment screw loosening.

2020 ◽  
Vol 24 (1) ◽  
Author(s):  
Ezzatollah Jalalian ◽  
Zahra Yousofi

Objectives: With regard to the prevalence of abutment screw loosening (SL) and bone height reduction, particularly in the posterior regions of the jaws, as well as the contradictory issue of applying short implants instead of surgeries, along with all preparations associated with longer implants, the present study aimed to compare the amount of torque loss in short implants with increased vertical cantilever abutments and standard ones. Material and Methods: In this experimental study, a total number of 20 implants (MegaGen Implant Co., Ltd, South Korea) with 4.5 mm diameter including 10 short implants (7 mm) and 10 standard ones (10 mm) were utilized. Using a surveyor, fixtures were perpendicularly mounted in 13×34 mm resin for short implants and 19×34 mm resin for standard ones. The abutments of the same height but different cuff heights (2.5 mm for the standard implants and 5.5 mm for the short ones) were then tightened with 30 N.cm, via a digital torque meter. To compensate the settling effect, the abutment screw was re-tightened with 30 N.cm after 10 min. Upon applying 500,000 cycles at 75 N.cm and 1 Hz along the longitudinal axis on each sample, blind reverse torque value (RTV) was measured with a digital torque meter. The data were finally analyzed using Student’s t-test. Results: Both groups experienced torque loss, but there was no statistically significant difference between the case and control groups in terms of abutment SL (p = 0451). Conclusion: Short implants seem to be a good mechanical alternative in emergencies with respect to torque loss and abutment SL. KEYWORDS Reverse torque value; Cyclic loading, Short implant; Screw loosening; Crown-implant ratio; Torque loss.


Materials ◽  
2021 ◽  
Vol 14 (22) ◽  
pp. 6832
Author(s):  
Mahnaz Arshad ◽  
Sina Khayat Zadeh ◽  
Mohammad Atai ◽  
Gholamreza Shirani ◽  
Georgios E. Romanos ◽  
...  

The aim of this study was to assess the effect of application of a recently developed bio-adhesive (Impladhesive) to abutment screw threads on the removal torque value and rotational misfit at the implant–abutment junction. This in vitro study evaluated 20 implant fixtures and 20 straight abutments. Specimens were randomly divided into two groups (n = 10) with/without adhesive application. In the adhesive group, the abutment was dipped in Impladhesive before torquing. In the control group, the abutment was torqued conventionally without adhesive application. The removal torque value was recorded after completion of the cyclic loading of 500,000 cycles with 2 Hz frequency and 75 N load. Rotational misfit was recorded using a video measuring machine. After applying the torque, the change in the bisector angle on the abutment hex was recorded for each implant. The biocompatibility of Impladhesive was evaluated using a MTT cell vitality assay. Normal distribution of data was assessed using the Kolmogorov–Smirnov test. Data were analyzed using a t-test and Pearson’s correlation coefficient The application of Impladhesive at the implant–abutment interface resulted in significantly greater mean removal torque value compared to the control group (p = 0.008). In addition, the mean rotational misfit at the implant–abutment interface was significantly lower in the use of Impladhesive compared to the control group (p = 0.001). In addition, the cell vitality was found to be greater than 80% at all evaluated time points. It can be concluded that the application of Impladhesive on the abutment screw significantly decreased rotational misfit and increased the removal torque value. Future studies are needed to evaluate the efficacy of this bio-adhesive an in vivo setting.


Author(s):  
Arda Ozdiler ◽  
suleyman dayan ◽  
Burc Gencel ◽  
Gulbahar Isık-Ozkol

This in vitro study evaluated the influence of taper angles on the internal conical connections of implant systems and of the application of chlorhexidine gel as an antibacterial agent or a polyvinyl siloxane (PVS) sealant on the reverse torque values of abutment screws after dynamic loading. The current study tested four implant systems with different taper angles (5.4°, 12°, 45°, and 60°). Specimens were divided into three groups: control (neither chlorhexidine gel filled nor silicone sealed), 2% chlorhexidine gel-filled or silicone-sealed group, and group subjected to a dynamic load of 50 N at 1 Hz for 500,000 cycles prior to reverse torque measurements. Quantitative positive correlation was observed between the taper angle degree and the percentage of tightening torque loss. However, this correlation was significant only for the 60° connection groups except in the group in which a sealant was applied ( p = 0.013 for the control group, p = 0.007 for the chlorhexidine group). Percentages of decrease in the torque values of the specimens with silicone sealant application were significantly higher compared with both the control and chlorhexidine groups ( p = 0.001, p = 0.002, p = 0.001, and p = 0.002, respectively, according to the increasing taper angles); the percentage of decrease in torque values due to chlorhexidine application was statistically insignificant when compared with the control group. The application of gel-form chlorhexidine as an antibacterial agent does not significantly affect the stability of the implant–abutment connection under dynamic loads. PVS sealants may cause screw loosening under functional loads.