scholarly journals Development and validation of a multivariate calibration model for determination of dipyrone in oral solutions by near infrared spectroscopy

2009 ◽  
Vol 20 (9) ◽  
pp. 1680-1686 ◽  
Author(s):  
Marcus H. Ferreira ◽  
Jorge F. F. Gomes ◽  
Marcelo M. Sena
2017 ◽  
Vol 63 (No. 5) ◽  
pp. 226-230 ◽  
Author(s):  
Zbíral Jiří ◽  
Čižmár David ◽  
Malý Stanislav ◽  
Obdržálková Elena

Determining and characterizing soil organic matter (SOM) cheaply and reliably can help to support decisions concerning sustainable land management and climate policy. Glomalin was recommended as one of possible indicators of SOM quality. Extracting glomalin from and determining it in soils using classical chemical methods is too complicated and therefore near-infrared spectroscopy (NIRS) was studied as a method of choice for the determination of glomalin. Representative sets of 84 different soil samples from arable land and grasslands and 75 forest soils were used to develop NIRS calibration models. The parameters of the NIRS calibration model (R = 0.90 for soils from arable land and grasslands and R = 0.94 for forest soils) proved that glomalin can be determined in air-dried soils by NIRS with adequate trueness and precision simultaneously with determination of nitrogen and oxidizable carbon.


2017 ◽  
Vol 25 (5) ◽  
pp. 338-347 ◽  
Author(s):  
Sudarno ◽  
Divo D Silalahi ◽  
Tauvik Risman ◽  
Baiq L Widyastuti ◽  
F Davrieux ◽  
...  

Near infrared spectroscopy calibrations for rapid oil content determination of dried-ground oil palm mesocarp and kernel were developed. Samples were analyzed, one set using the Soxhlet extraction method for reference analysis and the other set scanned by near infrared spectroscopy instrument for calibration. Successful calibrations were obtained with good accuracy and precision for mesocarp and kernel, based on statistical models. Math treatment and scatter correction had significant effects on the fitting of the calibration model. The best obtained calibration models were demonstrated by multiple correlation coefficient (R2), standard error of calibration, standard error of cross validation, coefficient of determination in cross validation (1-VR) and relative predictive deviation of calibration, which respectively were 0.997, 1.21%, 1.23%, 0.997 and 17.89 for mesocarp and 0.952, 0.47%, 0.53%, 0.94 and 4.00 for kernel. The correlations between reference and predicted values for samples in the validation sets were in agreement with high linearity, high ratio performance to deviation of prediction (≥4.00) and low standard error of prediction samples for both samples. The results demonstrated that near infrared spectroscopy can be used as an alternative and reliable technique to estimate the mesocarp and kernel oil contents in dry matter basis accurately and rapidly.


Sign in / Sign up

Export Citation Format

Share Document