2014 ◽  
Vol 590 ◽  
pp. 613-617
Author(s):  
Mulya Juarsa ◽  
Nandy Putra ◽  
Harinaldi ◽  
Anhar Riza Antariksawan

The Effect of gap size to counter current flow limitation (CCFL) in vertical rectangular channel was studied in this paper. Experiment was conducted by using two vertical plate with 1 mm, 2 mm, and 3 mm narrow gap. The initial temperature of plate was decided at 600oC. Flow rate and temperature of cooling water were controlled about 0.09 L/s and 90oC respectively. Non-dimensional superficial velocity for water is 0.05-0.09 and non-dimensional superficial velocity for vapor is 3.20-3.2. The result shows that the existence of CCFL in the vertical rectangular narrow channels. A new correlation for CCFL base on Wallis has been proposed.


Author(s):  
Christophe Vallée ◽  
Deendarlianto ◽  
Matthias Beyer ◽  
Dirk Lucas ◽  
Helmar Carl

Different scenarios of small break loss of coolant accident for pressurized water reactors (PWRs) lead to the reflux-condenser mode in which steam enters the hot leg from the reactor pressure vessel (RPV) and condenses in the steam generator. A limitation of the condensate backflow toward the RPV by the steam flowing in counter current could affect the core cooling and must be prevented. The simulation of counter-current flow limitation conditions, which is dominated by 3D effects, requires the use of a computational fluid dynamics (CFD) approach. These numerical methods are not yet mature, so dedicated experimental data are needed for validation purposes. In order to investigate the two-phase flow behavior in a complex reactor-typical geometry and to supply suitable data for CFD code validation, the “hot leg model” was built at Forschungszentrum Dresden-Rossendorf (FZD). This setup is devoted to optical measurement techniques, and therefore, a flat test-section design was chosen with a width of 50 mm. The test section outlines represent the hot leg of a German Konvoi PWR at a scale of 1:3 (i.e., 250 mm channel height). The test section is mounted between two separators, one simulating the RPV and the other is connected to the steam generator inlet chamber. The hot leg model is operated under pressure equilibrium in the pressure vessel of the TOPFLOW facility of FZD. The air/water experiments presented in this article focus on the flow structure observed in the region of the riser and of the steam generator inlet chamber at room temperature and pressures up to 3 bar. The performed high-speed observations show the evolution of the stratified interface and the distribution of the two-phase mixture (droplets and bubbles). The counter-current flow limitation was quantified using the variation in the water levels measured in the separators. A confrontation with the images indicates that the initiation of flooding coincides with the reversal of the flow in the horizontal part of the hot leg. Afterward, bigger waves are generated, which develop to slugs. Furthermore, the flooding points obtained from the experiments were compared with empirical correlations available in literature. A good overall agreement was obtained, while the zero penetration was found at lower values of the gaseous Wallis parameter compared with previous work. This deviation can be attributed to the rectangular cross section of the hot leg model.


2013 ◽  
Vol 57 ◽  
pp. 121-129 ◽  
Author(s):  
Chun-Yu Chen ◽  
Chunkuan Shih ◽  
Jong-Rong Wang ◽  
Hao-Tzu Lin

Sign in / Sign up

Export Citation Format

Share Document