scholarly journals DEVELOPMENT OF MOBILE DEVICE FOR GAMMA RADIATION MEASUREMENT UTILIZING LORA AS THE COMMUNICATION MEANS

2019 ◽  
Vol 21 (2) ◽  
pp. 79 ◽  
Author(s):  
I Putu Susila ◽  
Agung Alfiansyah ◽  
Istofa Istofa ◽  
Sukandar Sukandar ◽  
Budi Santoso ◽  
...  

Public protection is one of important issues when operating nuclear facility. In case of accident occurs, the facility owner and related organizations shall make decision whether to evacuate people or not, based on the level of the accident and radiation dose rate released to the environment. In this study, as part of the decision support system for nuclear emergency response, a prototype of mobile radiation measurement system has been developed. The device consists of Geiger-Muller (GM)-based radiation measurement board, Global Positioning System (GPS) module, microcontroller board, and low power LoRa module for communication. Radiation dose rate along with its geoposition were recorded and sent to base station equipped with LoRa gateway for connecting LoRa network to TCP/IP-based network. The measurement data is then published to storage server using Message Queuing Telemetry Transport (MQTT) protocol. Power consumption, measurement of counter/timer accuracy, communication ranges testing, and radiation dose rate measurement were performed around Puspiptek area to demonstrate the functionality of the system.Keywords: Radiation monitoring, Decision Support System, Mobile, LoRa, GPS

Author(s):  
Bert M. Coursey

In the late 1930s, a team of physicists from the National Bureau of Standards (now the National Institute of Standards and Technology) published eight papers on the investigation of cosmic rays in the atmosphere. Payloads launched with weather balloons, also known as radiosondes, were equipped with sensors to measure temperature, relative humidity, pressure, and radiation dose. A battery-operated telemetry system was used to continuously transmit at 60 MHz to a base station. They measured the radiation dose profiles of cosmic radiation in the atmosphere up to 21 km. Calibration of the Geiger-Müller counters with a standard radium source allowed them to calculate a radiation dose rate at an altitude corresponding to 10 kPa that was 180 times the dose rate near sea level in Washington, DC. Ascents in Washington, DC (latitude 39 degrees) and Lima, Peru (near equator) allowed them to demonstrate the effects of Earth’s magnetic field on incident galactic cosmic rays; the dose rate in Peru was only half that in Washington, DC.


2019 ◽  
Vol 5 (2) ◽  
pp. 25-39
Author(s):  
Luluk Suryani ◽  
Raditya Faisal Waliulu ◽  
Ery Murniyasih

Usaha Kecil Menengah (UKM) adalah salah satu penggerak perekonomian suatu daerah, termasuk Kota Sorong. UKM di Kota Sorong belum berkembang secara optimal. Ada beberapa penyebab diantaranya adalah mengenai finansial, lokasi, bahan baku dan lain-lain. Untuk menyelesaikan permasalah tersebut peneliti terdorong untuk melakukan pengembangan Aplikasi yang dapat membantu menentukan prioritas UKM yang sesuai dengan kondisi pelaku usaha. Pada penelitian ini akan digunakan metode Analitycal Hierarchy Process (AHP), untuk pengambilan keputusannya. Metode AHP dipilih karena mampu menyeleksi dan menentukan alternatif terbaik dari sejumlah alternatif yang tersedia. Dalam hal ini alternatif yang dimaksudkan yaitu UKM terbaik yang dapat dipilih oleh pelaku usaha sesuai dengan kriteria yang telah ditentukan. Penelitian dilakukan dengan mencari nilai bobot untuk setiap atribut, kemudian dilakukan proses perankingan yang akan menentukan alternatif yang optimal, yaitu UKM. Aplikasi Sistem Pendukung Keputusan yang dikembangkan berbasis Android, dimana pengguna akan mudah menggunakannya sewaktu-waktu jika terjadi perubahan bobot pada kriteria atau intensitas.  Hasil akhir menunjukkan bahwa metode AHP berhasil diterapkan pada Aplikasi Penentuan Prioritas Pengembangan UKM.


2014 ◽  
Author(s):  
Kamaruzaman S. ◽  
◽  
A. H. Omar ◽  
Muhammad Iqbal Tariq Idris ◽  
Izwyn Z. ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document