scholarly journals Is Continuous Glucose Monitoring Underappreciated in the UK?

2017 ◽  
Vol 13 (02) ◽  
pp. 76 ◽  
Author(s):  
Christopher G Parkin ◽  
Melissa Holloway ◽  
Jeffrey Truesdell ◽  
Tomas C Walker ◽  
◽  
...  

Introduction: Information about continuous glucose monitoring (CGM) use in the UK is limited. We conducted an online survey of a representative sample of current CGM users in England, Scotland and Wales to address this deficit. Methods: The 29-item online survey was conducted between 29 December 2016 and 25 January 2017. Persons with type 1 diabetes (T1D) and caregivers of T1D children/adolescents were recruited from mailing lists, using Nielsen and Harris Polling databases. Results: 315 patients and caregivers responded to the survey – 170 adult patients and 145 caregivers. Among respondents, 144 received full funding for CGM use, 72 received partial funding and 83 received no funding. Most reported improvements in glycated haemoglobin (HbA1c) (67.0%), fewer hypoglycaemia episodes (70.2%), improved hypoglycaemia awareness (77.5%) and better diabetes management (92.4%). Self-funders reported significantly higher CGM use (76.1%) than those who were fully funded (58.9%) and/or partially funded (65.9%), p=0.0008. Fewer than 50% of all respondents reported receiving guidance in interpreting CGM data from their diabetes care team; 30.1% of self-funders reported receiving no CGM support from their diabetes team compared with fully funded (2.8%) and partially funded (1.4%) respondents, p<0.0001. Conclusions: Patients with T1D and their caregivers are realising benefits from CGM use but are largely unsupported by the UK healthcare system.

Author(s):  
Emrah Gecili ◽  
Rui Huang ◽  
Jane C. Khoury ◽  
Eileen King ◽  
Mekibib Altaye ◽  
...  

Abstract Introduction: To identify phenotypes of type 1 diabetes based on glucose curves from continuous glucose-monitoring (CGM) using functional data (FD) analysis to account for longitudinal glucose patterns. We present a reliable prediction model that can accurately predict glycemic levels based on past data collected from the CGM sensor and real-time risk of hypo-/hyperglycemic for individuals with type 1 diabetes. Methods: A longitudinal cohort study of 443 type 1 diabetes patients with CGM data from a completed trial. The FD analysis approach, sparse functional principal components (FPCs) analysis was used to identify phenotypes of type 1 diabetes glycemic variation. We employed a nonstationary stochastic linear mixed-effects model (LME) that accommodates between-patient and within-patient heterogeneity to predict glycemic levels and real-time risk of hypo-/hyperglycemic by creating specific target functions for these excursions. Results: The majority of the variation (73%) in glucose trajectories was explained by the first two FPCs. Higher order variation in the CGM profiles occurred during weeknights, although variation was higher on weekends. The model has low prediction errors and yields accurate predictions for both glucose levels and real-time risk of glycemic excursions. Conclusions: By identifying these distinct longitudinal patterns as phenotypes, interventions can be targeted to optimize type 1 diabetes management for subgroups at the highest risk for compromised long-term outcomes such as cardiac disease or stroke. Further, the estimated change/variability in an individual’s glucose trajectory can be used to establish clinically meaningful and patient-specific thresholds that, when coupled with probabilistic predictive inference, provide a useful medical-monitoring tool.


2020 ◽  
pp. 193229682091889 ◽  
Author(s):  
Rachel S. Rigo ◽  
Laura E. Levin ◽  
Donald V. Belsito ◽  
Maria C. Garzon ◽  
Rachelle Gandica ◽  
...  

Background: Continuous glucose monitoring (CGM) and continuous subcutaneous insulin infusion (CSII) are the standard of care for type 1 diabetes in children. There is little reported on device-related skin complications and treatment options. This study documents cutaneous reactions to CGM and CSII devices in children and young adults with type 1 diabetes. Methods: One hundred and twenty-one subjects (3-25 years) with type 1 diabetes and CGM and/or CSII use were recruited over a three-month period from the Naomi Berrie Diabetes Center at Columbia University Irving Medical Center. A five-question survey was completed for each subject detailing demographic data, diabetes management, and device-related skin complications. Results: Sixty percent of subjects reported skin complications related to CGM and/or CSII use. Terms most frequently used to describe cutaneous reactions were “red,” “itchy,” “painful,” and “rash.” Subjects who used both CGM and CSII were more likely to report skin problems than those who used only CSII (odds ratio 2.9, [95% confidence interval: 1.2-6.7]; P = .015). There were no associations between skin complications and sex or race/ethnicity. Twenty-two percent of subjects with adverse skin event(s) discontinued use of a device due to their skin problem. Seven percent were evaluated by a dermatologist. Eighty-one percent used a range of products to treat their symptoms, with variable perceived clinical outcomes. Conclusions: Skin complications related to CSII or CGM devices are commonly reported in pediatric patients with type 1 diabetes and may lead to interruption or discontinuation of device use. Future studies are needed to elucidate the causes of these reactions and determine the best methods for prevention.


2019 ◽  
Vol 24 (2) ◽  
pp. 99-106
Author(s):  
Michelle Condren ◽  
Samie Sabet ◽  
Laura J. Chalmers ◽  
Taylor Saley ◽  
Jenna Hopwood

Type 1 diabetes mellitus has witnessed significant progress in its management over the past several decades. This review highlights technologic advancements in type 1 diabetes management. Continuous glucose monitoring systems are now available at various functionality and cost levels, addressing diverse patient needs, including a recently US Food and Drug Administration (FDA)–approved implantable continuous glucose monitoring system (CGMS). Another dimension to these state-of-the-art technologies is CGMS and insulin pump integration. These integrations have allowed for CGMS-based adjustments to basal insulin delivery rates and suspension of insulin delivery when a low blood glucose event is predicted. This review also includes a brief discussion of upcoming technologies such as patch-based CGMS and insulin-glucagon dual-hormonal delivery.


2012 ◽  
Vol 08 (01) ◽  
pp. 30
Author(s):  
Jeniece Trast ◽  
Neesha Ramchandani ◽  
◽  

Continuous glucose monitoring (CGM) systems, available for patient use since 1999, and realtime continuous glucose monitoring (RT-CGM) systems, available since 2006, have helped optimize diabetes management. Previously, RT-CGM studies found benefits mainly in patients with type 1 diabetes over the age of 25. Children and adolescents often present a challenge when managing type 1 diabetes. However, it is now apparent that RT-CGM has clear benefits in these age groups as well as in adults. Not only have studies shown improvements in glycemic control in this population, they have also demonstrated parental satisfaction with the technology. Challenges with RT-CGM use still exist and must be addressed. Nevertheless, RT-CGM is a beneficial tool to assist in diabetes management, and its use should be encouraged in the majority of pediatric patients with type 1 diabetes.


2020 ◽  
Vol 33 (7) ◽  
pp. 865-872
Author(s):  
Benjamin Udoka Nwosu ◽  
Shamima Yeasmin ◽  
Sanaa Ayyoub ◽  
Shwetha Rupendu ◽  
Tony R. Villalobos-Ortiz ◽  
...  

AbstractBackgroundPhysiologic hyperglycemia of puberty is a major contributor to poor glycemic control in youth with type 1 diabetes (T1D). This study’s aim was to determine the effectiveness of continuous glucose monitoring (CGM) to improve glycemic control in pubertal youth with T1D compared to a non-CGM cohort after controlling for age, sex, BMI, duration, and insulin delivery methodology. The hypothesis is that consistent CGM use in puberty improves compliance with diabetes management, leading to increased percentage (%) time in range (TIR70–180 mg/dL) of glycemia, and lowering of HbA1c.MethodsA longitudinal, retrospective, case-controlled study of 105 subjects consisting of 51 T1D controls (60.8% male) age 11.5 ± 3.8 y; and 54 T1D subjects (48.1% male) age 11.1 ± 5.0 y with confirmed CGM use for 12 months. Pubertal status was determined by Tanner staging. Results were adjusted for baseline HbA1c and diabetes duration.ResultsHbA1c was similar between the controls and the CGM group at baseline: 8.2 ± 1.1% vs 8.3 ± 1.2%, p=0.48 respectively; but was significantly lower in the CGM group 12 months later, 8.2 ± 1.1% vs. 8.7 ± 1.4%, p=0.035. Longitudinal change in HbA1c was similar in the prepubertal cohort between the control- and CGM groups: −0.17 ± 0.98% vs. 0.38 ± 1.5%, p=0.17. In contrast, HbA1c increased with advancing age and pubertal status in the pubertal controls but not in the pubertal CGM group: 0.55 ± 1.4 vs −0.22 ± 1.1%, p=0.020. Percent TIR was inversely related to HbA1c in the CGM group, r=-0.6, p=0.0004, for both prepubertal and pubertal subjects.ConclusionsCGM use significantly improved glycemic control in pubertal youth with T1D compared to non-CGM users.


Author(s):  
Astha Soni ◽  
Neil Wright ◽  
Juliana Chizo Agwu ◽  
Josephine Drew ◽  
Melanie Kershaw ◽  
...  

Type 1 diabetes is a self-managed condition. Regular monitoring of blood glucose (BG) levels has been the cornerstone of diabetes management. Finger prick BG testing traditionally has been the standard method employed. More recently, rapid advancements in the development of continuous glucose monitoring devices have led to increased use of technology to help children and young people with diabetes manage their condition. These devices have the potential to improve diabetes control and reduce hypoglycaemia especially if used in conjunction with a pump to automate insulin delivery. This paper aims to provide an update on main CGM devices available and practical considerations for doctors if they come across a child with diabetes who is using one of these devices.


2021 ◽  
Author(s):  
Stephanie R Johnson ◽  
Deborah J Holmes-Walker ◽  
Melissa Chee ◽  
Arul Earnest ◽  
Timothy W Jones ◽  
...  

<b>Objective:</b> Continuous glucose monitoring (CGM) is increasingly used in type 1 diabetes management however funding models vary. This study determined the uptake rate and glycaemic outcomes following a change in national health policy to introduce universal subsidised CGM funding for people with type 1 diabetes aged < 21 years. <p><b>Research Design and Methods:</b> Analysis of longitudinal data from 12 months prior to subsidy until 24 months after. Measures and outcomes included age, diabetes duration, HbA1c, episodes of diabetic ketoacidosis and severe hypoglycaemia, insulin regimen, CGM uptake and percentage CGM use. Two data sources were used: the Australasian Diabetes Database Network (ADDN) registry (a prospective diabetes database) and the National Diabetes Supply Scheme (NDSS) registry that includes almost all individuals with type 1 diabetes nationally.</p> <p><b>Results:</b> CGM uptake increased from 5% pre-subsidy to 79% after two years. After CGM introduction, the odds ratio (OR) of achieving the HbA1c target of <7.0% improved at 12 months (OR 2.5, p<0.001) and was maintained at 24 months (OR 2.3, p<0.001). The OR for suboptimal glycaemic control (HbA1c ≥ 9.0%) decreased to 0.34 (p<0.001) at 24 months. Of CGM users, 65% used CGM >75% of time: these had a lower HbA1c at 24 months compared to those with usage <25% (7.8±1.3% vs 8.6±1.8%, respectively, p<0.001). DKA was also reduced in this group (IRR 0.49, 95% CI 0.33-0.74, p<0.001).</p> <b>Conclusions:</b> <a></a>Following national subsidy, CGM use was high and associated with sustained improvement in glycaemic control. This information will inform economic analyses and future policy and serve as a model of evaluation diabetes technologies.


Sign in / Sign up

Export Citation Format

Share Document