scholarly journals Instrumental error sources in quantitative absorption spectroscopy

2016 ◽  
Vol 26 (2) ◽  
pp. 48-53
Author(s):  
Yu. P. Turov ◽  
◽  
D. A. Lazarev ◽  
1984 ◽  
Vol 39 (4) ◽  
pp. 399-411 ◽  
Author(s):  
M. Buback

Quantitative absorption spectroscopy in the infrared and near-infrared region enables kinetic and thermodynamic investigations to be performed on systems at high temperatures and pressures. The technique is illustrated for the ethylene polymerization. From spectroscopic experiments up to 3 kbar at maximum temperatures of 250 °C, the rate equations of the thermally, of the photochemically, and of the chemically initiated polymerization are determined.


2008 ◽  
Vol 112 (24) ◽  
pp. 8917-8921 ◽  
Author(s):  
Otto L. Muskens ◽  
Guillaume Bachelier ◽  
Natalia Del Fatti ◽  
Fabrice Vallée ◽  
Arnaud Brioude ◽  
...  

2019 ◽  
Vol 27 (26) ◽  
pp. 37920 ◽  
Author(s):  
Ryan K. Cole ◽  
Amanda S. Makowiecki ◽  
Nazanin Hoghooghi ◽  
Gregory B. Rieker

2012 ◽  
Vol 86 (16) ◽  
Author(s):  
Pascal Berto ◽  
Esteban Bermúdez Ureña ◽  
Pierre Bon ◽  
Romain Quidant ◽  
Hervé Rigneault ◽  
...  

Author(s):  
Микола Григорович Черняк ◽  
Владислав Володимирович Рибак ◽  
Віктор Анатолійович Палюшок

The paper is devoted to solving the problem of calibration with specified precision of triaxial block of navigation accelerometers on the uniaxial rotary stand.In paper introduced all the characteristics, for calibration of triaxial block of navigation accelerometers on the uniaxial rotary stand, instrumental error sources upon which was obtained mathematical errors model of calibration. This model allows to calculate the error which the coefficients of metrology model of triaxial accelerometer unit was identified, if we have the numerical values of precision equipment errors.Using the mathematical errors model of calibration, and the quality criterion of  calibration of triaxial block of navigation accelerometers unit, were obtained inequality that used to determine requirements for accuracy characteristics bench equipment, on which the calibration is performed.  These requirements ensure the calibration of triaxial block of navigation accelerometers on the uniaxial rotary stand with preset accuracy.Experimental verification was conducted on comparable accuracy errors existing equipment and the requirements to this equipment , confirm the adequacy of the obtained inequalities.As the result of research were identified the most influential sources of instrumental errors, and provided recommendations to reduce their impacts.


Sign in / Sign up

Export Citation Format

Share Document