scholarly journals Experimental study on SAR reduction from cell phones

ACTA IMEKO ◽  
2021 ◽  
Vol 10 (2) ◽  
pp. 147
Author(s):  
Marius-Vasile Ursachianu ◽  
Ovidiu Bejenaru ◽  
Catalin Lazarescu ◽  
Alexandru Salceanu

<p class="Abstract">The actual problem of the human exposure to different types of electromagnetic field sources is a challenging one and should be considered an up to date issue due to one major actual trend: the increasingly intensive penetration of various wireless communication technologies in virtually all places and times that make up our daily lives. The here presented paper presents an experimental study focused on measurements for three types of mobile phones, belonging to different generations, operating at the two characteristic frequencies of the GSM bandwidth. We have been used a SATIMO-COMOSAR evaluation dosimetry system, provided by the LICETER laboratory of ANCOM Romania. The determined values of the absorbed incident energy by the tissue of a mannequin (phantom) model for the human head, which is part of the dosimetry system, have been also compared with those obtained in the case when the mobile phones are protected by multilayer cases, aiming to study their possible limiting effect. The influence that ”touch” or ”tilt” positions might have on absorbed (by the human head model) incident energy values has also been investigated. The comparative processing of the obtained results allowed the formulation of recommendations on reducing the exposure to electromagnetic radiation associated with the use of the mobile phone. This paper is an extended and improved version of the original contribution to the IMEKO TC 4 2020 virtual conference.</p>

2021 ◽  
Vol 4 (1) ◽  
Author(s):  
Alireza Chamanzar ◽  
Marlene Behrmann ◽  
Pulkit Grover

AbstractA rapid and cost-effective noninvasive tool to detect and characterize neural silences can be of important benefit in diagnosing and treating many disorders. We propose an algorithm, SilenceMap, for uncovering the absence of electrophysiological signals, or neural silences, using noninvasive scalp electroencephalography (EEG) signals. By accounting for the contributions of different sources to the power of the recorded signals, and using a hemispheric baseline approach and a convex spectral clustering framework, SilenceMap permits rapid detection and localization of regions of silence in the brain using a relatively small amount of EEG data. SilenceMap substantially outperformed existing source localization algorithms in estimating the center-of-mass of the silence for three pediatric cortical resection patients, using fewer than 3 minutes of EEG recordings (13, 2, and 11mm vs. 25, 62, and 53 mm), as well for 100 different simulated regions of silence based on a real human head model (12 ± 0.7 mm vs. 54 ± 2.2 mm). SilenceMap paves the way towards accessible early diagnosis and continuous monitoring of altered physiological properties of human cortical function.


PeerJ ◽  
2017 ◽  
Vol 5 ◽  
pp. e4061 ◽  
Author(s):  
Awais Munawar Qureshi ◽  
Zartasha Mustansar

In this paper, we have presented a microwave scattering analysis from multiple human head models. This study incorporates different levels of detail in the human head models and its effect on microwave scattering phenomenon. Two levels of detail are taken into account; (i) Simplified ellipse shaped head model (ii) Anatomically realistic head model, implemented using 2-D geometry. In addition, heterogenic and frequency-dispersive behavior of the brain tissues has also been incorporated in our head models. It is identified during this study that the microwave scattering phenomenon changes significantly once the complexity of head model is increased by incorporating more details using magnetic resonance imaging database. It is also found out that the microwave scattering results match in both types of head model (i.e., geometrically simple and anatomically realistic), once the measurements are made in the structurally simplified regions. However, the results diverge considerably in the complex areas of brain due to the arbitrary shape interface of tissue layers in the anatomically realistic head model.After incorporating various levels of detail, the solution of subject microwave scattering problem and the measurement of transmitted and backscattered signals were obtained using finite element method. Mesh convergence analysis was also performed to achieve error free results with a minimum number of mesh elements and a lesser degree of freedom in the fast computational time. The results were promising and the E-Field values converged for both simple and complex geometrical models. However, the E-Field difference between both types of head model at the same reference point differentiated a lot in terms of magnitude. At complex location, a high difference value of 0.04236 V/m was measured compared to the simple location, where it turned out to be 0.00197 V/m. This study also contributes to provide a comparison analysis between the direct and iterative solvers so as to find out the solution of subject microwave scattering problem in a minimum computational time along with memory resources requirement.It is seen from this study that the microwave imaging may effectively be utilized for the detection, localization and differentiation of different types of brain stroke. The simulation results verified that the microwave imaging can be efficiently exploited to study the significant contrast between electric field values of the normal and abnormal brain tissues for the investigation of brain anomalies. In the end, a specific absorption rate analysis was carried out to compare the ionizing effects of microwave signals to different types of head model using a factor of safety for brain tissues. It is also suggested after careful study of various inversion methods in practice for microwave head imaging, that the contrast source inversion method may be more suitable and computationally efficient for such problems.


2021 ◽  
Vol 36 (2) ◽  
pp. 159-167
Author(s):  
Fatih Kaburcuk ◽  
Atef Elsherbeni

Numerical study of electromagnetic interaction between an adjacent antenna and a human head model requires long computation time and large computer memory. In this paper, two speeding up techniques for a dispersive algorithm based on finite-difference time-domain method are used to reduce the required computation time and computer memory. In order to evaluate the validity of these two speeding up techniques, specific absorption rate (SAR) and temperature rise distributions in a dispersive human head model due to radiation from an antenna integrated into a pair of smart glasses are investigated. The antenna integrated into the pair of smart glasses have wireless connectivity at 2.4 GHz and 5th generation (5G) cellular connectivity at 4.9 GHz. Two different positions for the antenna integrated into the frame are considered in this investigation. These techniques provide remarkable reduction in computation time and computer memory.


Author(s):  
X. Gary Tan ◽  
Amit Bagchi

Abstract Combat helmets have gone through many changes, from shells made of metal to advanced composites using Kevlar and Dyneema, along with introduction of pad suspensions to provide comfort and protection. Helmets have been designed to perform against ballistic and blunt impact threats. But, in today’s warfare, combat helmets are expected to protect against all three threats, blunt, ballistic impacts and blast effects to minimize traumatic brain injury (TBI) and provide a better thermal comfort. We are developing a helmet system analysis methodology integrating the effect of multiple threats, i.e., blast and blunt impacts, to achieve an optimal helmet system design, by utilizing multi-physics computational tools. We used a validated human head model to represent the warfighter’s head. The helmet composite shell was represented by an orthotropic elasto-plastic material model. A strain rate dependent model was employed for pad suspension material. Available dynamic loading data was used to calibrate the material parameters. Multiple helmet system configurations subjected to blast and blunt loadings were considered to quantify their influence on brain biomechanical response. Parametric studies were carried out to assess energy absorption for different suspension geometry and material morphology for different loadings. The resulting brain responses were used with published injury criteria to characterize the helmet system performance through a single metric for each threat type. Approaches to combine single-threat metrics to allow aggregating performance against multiple threats were discussed.


Sign in / Sign up

Export Citation Format

Share Document