scholarly journals Biometric indicators of Eyes with Occult Lens Subluxation inducing Secondary Acute Angle Closure

2019 ◽  
Author(s):  
Xiaoli Xing ◽  
Liangyu Huang ◽  
Fang Tian ◽  
Yan Zhang ◽  
Yingjuan Lv ◽  
...  

Abstract Background : To compare the anterior biometricsof eyes with secondary acute angle closure induced by occult lens subluxation (ASAC-LS), which were misdiagnosed at the first visit withacute primary angle closure (APAC), chronic primary angle closure glaucoma (CPACG), or cataracts. Methods: This retrospective case series ncluded 17 eyes with angle closure due to occult LS which were misdiagnosed with APAC at the first visit, 56 APACeyes, 54 CPACGeyes, and 56 cataracteyes. The axial length (AL), central corneal thickness (CCT), anterior chamber depth (ACD), aqueous depth (AD), and lens thickness (LT) were recorded. The lens position (LP), relative lens position (RLP), and corrected lens position (CLP) were calculated. Quantitative data were subject to a one-way analysis of variance and correlation analysis. Categorical data were analysed using the chi-squared test. Receiver operating characteristic (ROC) curves were plotted to obtain a suitable cut-off value for ocular biometrics. Results: The ASAC-LSpatients had a longer ocular AL than the APACand CPACGpatients. The CCTinthe ASAC-LS patientsdid not significantly differ from that in the APAC patientsbut did significantly differ from that of the CPACG and cataract patients.The APAC patientshad the smallest ACD, while the ASAC-LS patientshad the smallest AD. The ASAC-LS patientshad the thickest lenses. According to the ROC curve analysis, the RLP, ACD, AD, CLP, and LP hada high power of discrimination. Conclusions: This study revealed that ASAC-LS patients had a shallower AD and thicker CCT compared to APAC, CPACG, and cataract patients. Biometric parameters ACD, ADwere characteristic of lens subluxation according to our data. The calculated parameters RLP,CLP, LP can be helpful in the differential diagnosis between ASAC-LSand APAC, CPACG, Cataract. Trial registration: NCT03752710, retrospectively registered. Keywords:Lens subluxation; Acute angle-closure; Biometry; Anterior chamber depth; Lens thickness; Axial length

2019 ◽  
Author(s):  
Xiaoli Xing ◽  
Liangyu Huang ◽  
Fang Tian ◽  
Yan Zhang ◽  
Yingjuan Lv ◽  
...  

Abstract Background: To compare the anterior biometry of eyes with secondary acute angle closure induced by occult lens subluxation (LS), misdiagnosed as acute primary angle closure (APAC) at the first visit, APAC, chronic primary angle closure glaucoma (CPACG), cataract. Methods: This retrospective case study included 17 eyes with PAC due to occult LS, who were misdiagnosed as APAC on their first visit, 56 eyes diagnosed as APAC, 54 eyes diagnosed as CPACG, and 56 eyes diagnosed as cataract. Axial length (AL), Central corneal thickness (CCT), anterior chamber depth (ACD) and lens thickness (LT) were recorded. Lens position (LP), relative lens position (RLP), corrected lens position (CLP) were calculated. Quantitative data were subject to one-way analysis of variance and correlation analysis. Categorical data were analyzed using the chi-squared test. Results: The patients in the LS group had a longer ocular axial length than those with acute angle closure and CPACG. Corneal thickness in the LS group was not significantly different from that in the APAC group, but was significantly different from those of the CPACG and cataract group. The APAC group had the smallest ACD, while the LS group had the smallest AD. The LS group exhibited significantly shallower ACD (P<0.01). The LS group had the largest lens thickness. Conclusions: This study revealed that LS secondary PAC patients had a shallower ACD, thicker CCT and lens thickness comparing to those of APAC, CPACG and cataract patients. A short depth (< 1.25 mm) and a thick lens thickness (> 5.13 mm) are crisis of lens subluxation in our data. LP and CLP can be helpful for differential diagnosis. Trial registration: NCT03752710, retrospectively registered.


2019 ◽  
Author(s):  
Xiaoli Xing ◽  
Liangyu Huang ◽  
Fang Tian ◽  
Yan Zhang ◽  
Yingjuan Lv ◽  
...  

Abstract Background : To compare the anterior biometry of eyes with secondary acute angle closure induced by occult lens subluxation (LS), misdiagnosed as acute primary angle closure (APAC) (ASAC-LS ) at the first visit, APAC, chronic primary angle closure glaucoma (CPACG), cataract. Methods : This retrospective case study included 17 eyes with primary angel closure(PAC)due to occult LS, who were misdiagnosed as APAC on their first visit, 56 eyes diagnosed as APAC, 54 eyes diagnosed as CPACG, and 56 eyes diagnosed as cataract. Axial length (AL), central corneal thickness (CCT), anterior chamber depth (ACD) , aqueous depth (AD) and lens thickness (LT) were recorded. Lens position (LP), relative lens position (RLP), corrected lens position (CLP) were calculated. Quantitative data were subject to one-way analysis of variance and correlation analysis. Categorical data were analyzed using the chi-squared test. Receiver operating characteristic (ROC) curves were plotted to obtain a suitable cutoff value of ocular biometry. Results: The patients in the ASAC-LS group had a longer ocular axial length than those with acute angle closure and CPACG. Corneal thickness in the ASAC-LS group was not significantly different from that in the APAC group, but was significantly different from those of the CPACG and cataract group. The APAC group had the smallest ACD, while the ASAC-LS group had the smallest AD. The ASAC-LS group exhibited significantly shallower AD (P<0.01). The ASAC-LS group had the largest lens thickness. According to ROC curve analysis,RLP, ACD, AD, LP, CLP, CCT were high power of discrimination. Conclusions: This study revealed that LS secondary PAC patients had a shallower AD, thicker CCT comparing to those of APAC, CPACG and cataract patients. LP and CLP can be helpful for differential diagnosis.


2019 ◽  
Author(s):  
Xiaoli Xing ◽  
Liangyu Huang ◽  
Yan Zhang ◽  
Yingjuan Lv ◽  
Wei Liu ◽  
...  

Abstract Background: To compare the anterior biometry of eyes with secondary acute angle closure induced by occult lens subluxation (LS), misdiagnosed as acute primary angle closure (APAC) at the first visit, APAC, chronic primary angle closure glaucoma (CPACG), cataract. Methods: This retrospective case study included 17 eyes with PAC due to occult LS, who were misdiagnosed as APAC on their first visit, 56 eyes diagnosed as APAC, 54 eyes diagnosed as CPACG, and 56 eyes diagnosed as cataract. Axial length (AL), Central corneal thickness (CCT), anterior chamber depth (ACD) and lens thickness (LT) were recorded. Lens position (LP), relative lens position (RLP), corrected lens position (CLP) were calculated. Quantitative data were subject to one-way analysis of variance and correlation analysis. Categorical data were analyzed using the chi-squared test. Results: The patients in the LS group had a longer ocular axial length than those with acute angle closure and CPACG. Corneal thickness in the LS group was not significantly different from that in the APAC group, but was significantly different from those of the CPACG and cataract group. The APAC group had the smallest ACD, while the LS group had the smallest AD. The LS group exhibited significantly shallower ACD (P<0.01). The LS group had the largest lens thickness. Conclusions: This study revealed that LS secondary PAC patients had a shallower ACD, thicker CCT and lens thickness comparing to those of APAC, CPACG and cataract patients. A short depth (< 1.25 mm) and a thick lens thickness (> 5.13 mm) are crisis of lens subluxation in our data. LP and CLP can be helpful for differential diagnosis. Trial registration: NCT03752710, retrospectively registered.


2020 ◽  
Author(s):  
Xiaoli Xing ◽  
Liangyu Huang ◽  
Fang Tian ◽  
Yan Zhang ◽  
Yingjuan Lv ◽  
...  

Abstract Background: To compare the anterior biometrics of eyes with secondary acute angle closure induced by occult lens subluxation (ASAC-LS), misdiagnosed as acute primary angle closure (APAC) at the first visit with APAC, chronic primary angle closure glaucoma (CPACG), and cataract. Methods : This retrospective case study included 17 eyes with angel closure due to occult LS, who were misdiagnosed as APAC on their first visit, 56 APAC eyes, 54 CPACG eyes, and 56 cataract eyes. Axial length (AL), central corneal thickness (CCT), anterior chamber depth (ACD) , aqueous depth (AD) and lens thickness (LT) were recorded. Lens position (LP), relative lens position (RLP), corrected lens position (CLP) were calculated. Quantitative data were subject to one-way analysis of variance and correlation analysis. Categorical data were analyzed using the chi-squared test.Receiver operating characteristic (ROC) curves were plotted to obtain a suitable cutoff value of ocular biometrics. Results: The ASAC-LS patients had a longer ocular axial length than APACand CPACGpatients. Central corneal thickness ofthe ASAC-LSpatientswas not significantly different from APAC patients, but was significantly different from CPACG and cataract patients. The APAC patientshad the smallest ACD, while the ASAC-LS patientshad the smallest AD. The ASAC-LS patientshad the largest lens thickness. According to ROC curve analysis, RLP, ACD, AD, CLP, LP hadhigh power of discrimination. Conclusions: This study revealed that LS secondary PAC patients had a shallower AD, thicker CCT comparing to those of APAC, CPACG and cataract patients.LP and CLP can be helpful for differential diagnosis. Trial registration: NCT03752710, retrospectively registered. Keywords: Lens subluxation; Acute angle-closure; Biometry; Anterior chamber depth; Lens thickness; Axial length


2018 ◽  
Vol 2018 ◽  
pp. 1-6
Author(s):  
Wei-ran Niu ◽  
Chun-qiong Dong ◽  
Xi Zhang ◽  
Yi-fan Feng ◽  
Fei Yuan

Purpose. To investigate the biometric characteristics of Chinese patients with a history of acute angle closure (AAC). Methods. In this clinic-based, retrospective, observational, cross-sectional study, biometric parameters of eyes were acquired from a general population of Chinese adults. The crowding value (defined as lens thickness (LT); central corneal thickness (CCT); anterior chamber depth (ACD)/axial length (AL)) was calculated for each patient. Logistic regression analysis was performed to identify risk factors for AAC. Receiver operating characteristic (ROC) curves were plotted, and biometric variables were compared to compile a risk assessment for AAC. Result. This study included 1500 healthy subjects (2624 eyes, mean age of 66.54 ± 15.82 years) and 107 subjects with AAC (202 eyes, mean age of 70.01 ± 11.05 years). Eyes with AAC had thicker lens (P≤0.001), shallower anterior chamber depth (P≤0.001), and shorter axial length (P≤0.001) than healthy eyes. Logistic regression analysis and ROC curve analysis indicated that a crowding value above 0.13 was a significant (P<0.05) risk factor for the development of AAC. Conclusions. Biometric parameters were significantly different between the eyes from the AAC group to the normal group. Ocular crowding value might be a new noncontact screening method to assess the risk of AAC in adults.


2015 ◽  
Vol 74 (1) ◽  
Author(s):  
Khathutshelo P. Mashige

Aim: The reliability of an instrument used to collect data for clinical and research purposes is greatly important, especially when it is used to determine changes in measured ocular parameters over time. The purpose of this study was to determine the intra-session repeatability and inter-session reproducibility of axial length (AL), anterior chamber depth (ACD) and crystalline lens thickness (LT) measurements using the Nidek US-500 Echoscan.Method: Fifty successive automatic measurements of the above parameters were taken on the right eyes only of 12 healthy subjects aged 23–44 years old, followed by similar repeated measures after 1 week. Sample standard deviations (s.d.), precision (P) and coefficient of repeatability (COR) were calculated to determine intra-session repeatability. Coefficient of reproducibility (CRP), Bland and Altman plots, concordance correlation coefficients (CCC) and paired t-tests that compared measurements obtained in the first and second sessions, were used to determine inter-session reproducibility.Results: Both the intra-session repeatability and inter-session reproducibility were within acceptable limits for the three variables assessed.Conclusion: The study showed that the Nidek US-500 Echoscan provides accurate, repeatable and reproducible measurements of AL, ACD and LT in healthy eyes. This finding will be of interest to optometrists and ophthalmologists who measure these parameters when diagnosing, managing and investigating conditions such as primary angle-closure glaucoma and keratoconus.


2021 ◽  
Vol 2021 ◽  
pp. 1-5
Author(s):  
Xiaoli Xiang ◽  
Yuan Chen ◽  
Jinyu Wang ◽  
Zhengru Huang ◽  
Zheng Gu

The management of acute angle closure combined with an extremely shallow anterior chamber and cataract remains complex. This study evaluated a technique of vitreous needle aspiration combined with phacoemulsification for the treatment of acute angle closure with continuous high intraocular pressure (IOP). We retrospectively reviewed the results of vitreous needle aspiration combined with phacoemulsification in 17 eyes (17 patients) with acute angle closure with continuous high IOP and coexisting visually significant cataracts between September 2018 and April 2020 at the glaucoma unit of the affiliated Changshu Hospital of Xuzhou Medical University. The main outcomes were the best corrected visual acuity (BCVA), IOP, anterior chamber depth (ACD), angle open distance 500 (AOD500), number of antiglaucoma medications, and surgery-associated complications. There were no complications during phacoemulsification and a foldable acrylic intraocular lens was implanted in the capsular bag in all 17 patients. For all patients, vitreous needle aspiration was successful at the first attempt. The BCVA improved from 2.02 ± 0.54 logMAR preoperatively to 0.73 ± 0.57 logMAR postoperatively at the final examination ( p < 0.001 ). The mean IOP was 54.47 ± 5.33 mmHg preoperatively and 15.59 ± 2.35 mmHg at the final examination ( p < 0.001 ) without any medication. The ACD was 1.70 ± 0.16 mm preoperatively and 3.35 ± 1.51 mm at the final examination ( p < 0.001 ). The AOD500 was 0.07 ± 0.02 mm preoperatively and 0.51 ± 0.04 mm at the final examination ( p < 0.001 ). Our vitreous needle aspiration technique can be performed safely in phacoemulsification for the management of acute angle closure with continuous high IOP.


2019 ◽  
Author(s):  
Hong-Yang Zhang ◽  
Hong-Liang Lin ◽  
Yong-Jie Qin ◽  
Yu-Lin Zhang ◽  
Yu-Qiao Zhang ◽  
...  

Abstract BackgroundTo compare clinical characteristics of lens subluxation between eyes with or without acute angle closure (AAC).MethodsThis is a retrospective and case control study. Thirty-four cases with lens subluxation were recruited from 2015 to 2017. Patients with acute angle closure were assigned to the AAC group (n=17 eyes) and those without AAC were in the non-AAC group (n=17 eyes). Quantitative anterior segment was evaluated by ultrasound biomicroscopy (UBM). Axial length (AL) was measured with IOL master. All patients underwent lens extraction surgery and were followed up for 6 months. ResultsThe history of blunt trauma was accounted for 11 (64.7%) cases in the AAC group and 14 (82.3%) cases in the non-AAC group. Nine (52.9%) patients in the AAC group had LPI or SPI treatment history, and high intraocular pressure was recurred. The UBM analysis showed that the average central ACD of affected eyes in the AAC group was 1.75 mm, which was significantly shallower than the fellow eyes (2.39 mm, P < 0.05) or both eyes in the non-AAC group (affected eye 3.24mm vs fellow eye 3.81mm). Lens vault and AOD500 also showed a remarkable difference between affected eye than fellow eye (P < 0.001) in the AAC group. The both eyes in the AAC group presented a shorter AL and shallower anterior chamber, comparing with those in the non-AAC group. Besides, the affected eyes in the AAC group presented significantly higher LV. ConclusionsThe crowded anterior chamber structure and shorter AL might be an anatomic basis for the eye with lens subluxation induced AAC. Quantitative evaluation of these ocular structures to identify zonular compromise, increased LV and shorter AL are valuable for the diagnosis of lens subluxation induced AAC.


2021 ◽  
Vol 1 (1) ◽  
pp. 10
Author(s):  
Ni Putu Ayu Reza Dhiyantari ◽  
Nurwasis Nurwasis ◽  
Evelyn Komaratih ◽  
Yulia Primitasari

Introduction: Primary Angle-Closure Glaucoma (PACG) is usually present in adults older than forty and is more common in hyperopic eyes. Angle-closure is usually related to structural or developmental ocular abnormalities in young individuals. Case presentation: We presented a rare case of PACG in a 32 years old woman with pathologic myopia of -23.0 RLE. The chief complaint was blurring of the right eye three months before the visit. Right eye Intraocular Pressure (IOP) was 30mmHg-38mmHg despite treatment with three intra-ocular pressure-lowering agents. Axial length was 32.36 mm and 31.19 mm RLE. Anterior chamber depth was 2.36 mm and 2.60 mm RLE. Lens thickness was 5.07 mm and 5.40 mm RLE. Signs of GON and pathologic myopia were found in both eyes. GON was present asymmetrically (0.9 and 0.6 RLE), with the myopic crescent as well as baring and peripapillary atrophy. The optic disc was slightly tilted with the myopic crescent. There was also a marked sign of retinal pigment epithelium thinning and attenuation along with myopic chorioretinal atrophy. Conclusions: PACG in a young myopic individual is challenging to diagnose because myopia and glaucoma share similar optic nerve head pathology. Comprehensive examinations including gonioscopy, biometry, and OCT may confirm the diagnosis. In the presented case, angle-closure was caused by thick lenses and a shallow anterior chamber, along with excessively long axial length. Primary angle-closure at a young individual with myopic eyes is highly uncommon. Nonetheless, clinicians should always consider glaucoma even in the presence of high axial length and myopic fundus.