Sensitive Electrochemical Monitoring of Piroxicam in Pharmaceuticals Using Carbon Ionic Liquid Electrode

2018 ◽  
Vol 15 (1) ◽  
pp. 45-50 ◽  
Author(s):  
Ghazal Ghobadpour ◽  
Fatemeh Farjami ◽  
Farshid Fasihi

Background: Piroxicam is a non-steroidal anti-inflammatory drug. The prevailing clinical use and investigation of piroxicam necessitate a rapid and sensitive method for its determination. A carbon ionic liquid electrode, fabricated using graphite and the ionic liquid 1-octylpyridinium hexafluorophosphate (OPFP) was used as an electrochemical sensor for piroxicam determination. Methods: The surface of the proposed electrode was characterized by scanning electron microscopy. Cyclic voltammetry (CV) was applied to study the oxidation of piroxicam and to acquire information about the reaction mechanism. Differential pulse voltammetry was also used as an analytical technique for quantification of the sub-micromolar concentration of piroxicam. Results: One oxidation peak at 0.55V was observed at CILE. The oxidation peak at the CPE was weak, while the response was notably increased at the CILE. The proposed electrode exhibited interesting sensitivity towards the determination of piroxicam and the anodic peak current versus piroxicam concentration was linear in the ranges of 0.2-60 µM. The detection limit of 40 nM was achieved. Conclusion: The electroxidation process was irreversible and revealed adsorption controlled behavior. The method was successfully applied for the determination of piroxicam content in pharmaceutical samples.

2012 ◽  
Vol 59 (12) ◽  
pp. 1584-1590 ◽  
Author(s):  
Chengxiang Ruan ◽  
Tongtong Li ◽  
Xiuzheng Wang ◽  
Xiaowei Qi ◽  
Jin Lou ◽  
...  

2008 ◽  
Vol 133 (2) ◽  
pp. 387-392 ◽  
Author(s):  
Wei Sun ◽  
Yinzhuo Li ◽  
Maoxia Yang ◽  
Jiao Li ◽  
Kui Jiao

RSC Advances ◽  
2017 ◽  
Vol 7 (19) ◽  
pp. 11322-11330 ◽  
Author(s):  
Azadeh Fatahi ◽  
Reihaneh Malakooti ◽  
Mohsen Shahlaei

A novel, simple, sensitive and selective electrochemical sensor based on an Fe3O4/PANI–CuII microsphere modified carbon ionic liquid electrode is constructed and utilized for the determination of dexamethasone.


2012 ◽  
Vol 554-556 ◽  
pp. 440-444
Author(s):  
He Zhen Wu ◽  
Aie Cao ◽  
Di Lou Xu ◽  
Dao Bao Chu

Electrocatalytic oxidation of multi-nanostructured active electrode modified by platinum nanoparticles on glucose was examined. Based on 0.5mol/L KOH solution, we see a sensitive and good-shaped oxidation peak current near -0.77V (VS, SCE) by using differential pulse voltammetry method to scan in the range of -0.9~0.4V.The peak is regarded as the quantitative peak. There is a good linear relationship between glucose concentration and the peak current in the range of 1.0×10-2~1.0×10-5 mol/L. The linear correlation coefficient is 0.99864.The detection limit is 1.0×10-6mol/L. If added 0.06 m mol/L ascorbic acid or 0.3m mol/L uric acid (simulating human blood components), the determination of glucose is not interfered with. Results of the determination of glucose concentration in the blood are satisfactory.


Sign in / Sign up

Export Citation Format

Share Document