Bioanalytical Method Development of Atenolol Enantiomers: Stereoselective Behavior in Rabbit Plasma by RP-UFLC Method

2019 ◽  
Vol 16 ◽  
Author(s):  
Charan Raju C ◽  
B M Gurupadayya ◽  
Prachi Raikar

Objective: The objective of the method was to develop a new, simple and reliable enantioselective Reverse Phase- Ultra Fast Liquid Chromatography (RP-UFLC) method for the separation of Atenolol enantiomers. Comprehensive study was performed by extending the work to pharmacokinetic studies using rabbit plasma. Background: Many methods were reported for enantioseparation of Atenolol enantiomers but, no attempts were made for chiral separation of Atenolol using rabbit plasma. Moreover, pharmacokinetic data to prove the efficiency of particular enantiomers in rabbit plasma was not studied. Method: In the present examination, the binary RP-UFLC technique was developed on Phenomenex® Lux cellulose i5 segment (150×4.6 mm, 5µ) using di-sodium hydrogen phosphate buffer (pH 6.8): acetonitrile (35:65 v/v) as the mobile phase. Results: The elution of Atenolol was observed at 225 nm with a stream rate of 1 mL.min-1. The described technique offered a linear relationship with a regression coefficient of r2= 0.997 and 0.996 for (R) and (S)-enantiomer respectively between the concentration range of 2-10 ng.mL-1. Atenolol enantiomers were detected at a retention time (tR) of 2.7 min and 3.10 min R and S-enantiomer respectively. The rate of recovery of both Atenolol enantiomers was observed to be (R) 98.18% and (S) 100.45% individually. USFDA guidelines May 2018, were systematically followed for bioanalytical method development and validation. Conclusion: The developed technique was applied for the separation of Atenolol enantiomers and for the pharmacokinetic determination of Atenolol enantiomers in rabbit plasma.

2020 ◽  
Vol 11 (4) ◽  
pp. 7854-7862
Author(s):  
Potturi Ramadevi ◽  
Kantipudi Rambabu

For the gradation of Ezetimibe and Pitavastain in rabbit plasma, a highly sensitive and simple LC-MS/MS assay was developed and witnessed. The chromatographic conditions are isocratic with a waters symmetry C18 (150 x 4.6 mm, 3.5) column in isocratic mode. The detection was carried out using a mobile phase of 0.1 percent formic acid and 60:40 acetonitrile, and the detection was carried out using MS in a positive mode of electrospray ionisation. The valid approach was checked with a linear range of 10-200 ng/ml Ezetimibe and 2-40 ng/ml Pitavastain. The intraday and interday precision values were found to be within reasonable limits. The liquid extraction process is used to remove these drugs from rabbit plasma. And these drugs have been shown to be stable in freeze-thaw, autosampler, and benchtop tests in the future. The fluid chromatography coupled mass spectrometry strategy was approved by the US Food and Drug Administration for quantification of Ezetimibe and Pitavastain in rabbit plasma using D4–ezetimibe and D4–pitavastain as within norms using LC-MS consolidated with quadrupole spectrometer by electro shower ionisation process. The aim of this study is to evaluate the applicability of this approach to ezetimibe and pitavastain at different evaluation levels while taking into account various factors such as instrument stability, precision, and accuracy, sample preparation techniques, instrument calibration, recovery, and matrix effect by using Ezetimibe and Pitavastain, as well as their internal guidelines.


Author(s):  
SYED RAFI ◽  
KANTIPUDI RAMBABU

Objective: An easy, quick, precise, active and reproducible LC-MS/MS technique was developed for the bioanalytical method of Avelumab and Axitinib using Cytarabine as an internal standard. Methods: This article summarizes the recent progress on bioanalytical LC-MS/MS methods using waters x-bridge phenyl column (150x4.6 mm, 3.5µ) column and organic mobile phase of 0.1% Tri fluoro acetic acid and Acetonitrile in 50:50 ratio. Results: The calibration curve was linear in the range of 2-40 ng/ml for avelumab and 0.5-10 ng/ml axitnib. Accuracy, precision, recovery, matrix effect and stability results were found to be within the suitable limits. Simple and efficient method was developed and utilized in pharmacokinetic studies to see the investigated analyte in body fluids. Conclusion: The application denotes all the parameters of system suitability, specificity, linearity and accuracy are in good agreement with USFDA guidelines and applied effectively for the investigation of pharmacokinetic studies in rabbit.


Sign in / Sign up

Export Citation Format

Share Document