Effects of Noise Type and Signal-to-Noise Ratio on Word Recognition Performance of Adults and Children with Normal Hearing Sensitivity

2013 ◽  
Vol 9 (2) ◽  
pp. 137-147 ◽  
Author(s):  
Hyunsook Jang ◽  
Seulki Jeon
1992 ◽  
Vol 35 (4) ◽  
pp. 942-949 ◽  
Author(s):  
Christopher W. Turner ◽  
David A. Fabry ◽  
Stephanie Barrett ◽  
Amy R. Horwitz

This study examined the possibility that hearing-impaired listeners, in addition to displaying poorer-than-normal recognition of speech presented in background noise, require a larger signal-to-noise ratio for the detection of the speech sounds. Psychometric functions for the detection and recognition of stop consonants were obtained from both normal-hearing and hearing-impaired listeners. Expressing the speech levels in terms of their short-term spectra, the detection of consonants for both subject groups occurred at the same signal-to-noise ratio. In contrast, the hearing-impaired listeners displayed poorer recognition performance than the normal-hearing listeners. These results imply that the higher signal-to-noise ratios required for a given level of recognition by some subjects with hearing loss are not due in part to a deficit in detection of the signals in the masking noise, but rather are due exclusively to a deficit in recognition.


2014 ◽  
Vol 25 (06) ◽  
pp. 529-540 ◽  
Author(s):  
Erin C. Schafer ◽  
Danielle Bryant ◽  
Katie Sanders ◽  
Nicole Baldus ◽  
Katherine Algier ◽  
...  

Background: Several recent investigations support the use of frequency modulation (FM) systems in children with normal hearing and auditory processing or listening disorders such as those diagnosed with auditory processing disorders, autism spectrum disorders, attention-deficit hyperactivity disorder, Friedreich ataxia, and dyslexia. The American Academy of Audiology (AAA) published suggested procedures, but these guidelines do not cite research evidence to support the validity of the recommended procedures for fitting and verifying nonoccluding open-ear FM systems on children with normal hearing. Documenting the validity of these fitting procedures is critical to maximize the potential FM-system benefit in the abovementioned populations of children with normal hearing and those with auditory-listening problems. Purpose: The primary goal of this investigation was to determine the validity of the AAA real-ear approach to fitting FM systems on children with normal hearing. The secondary goal of this study was to examine speech-recognition performance in noise and loudness ratings without and with FM systems in children with normal hearing sensitivity. Research Design: A two-group, cross-sectional design was used in the present study. Study Sample: Twenty-six typically functioning children, ages 5–12 yr, with normal hearing sensitivity participated in the study. Intervention: Participants used a nonoccluding open-ear FM receiver during laboratory-based testing. Data Collection and Analysis: Participants completed three laboratory tests: (1) real-ear measures, (2) speech recognition performance in noise, and (3) loudness ratings. Four real-ear measures were conducted to (1) verify that measured output met prescribed-gain targets across the 1000–4000 Hz frequency range for speech stimuli, (2) confirm that the FM-receiver volume did not exceed predicted uncomfortable loudness levels, and (3 and 4) measure changes to the real-ear unaided response when placing the FM receiver in the child’s ear. After completion of the fitting, speech recognition in noise at a –5 signal-to-noise ratio and loudness ratings at a +5 signal-to-noise ratio were measured in four conditions: (1) no FM system, (2) FM receiver on the right ear, (3) FM receiver on the left ear, and (4) bilateral FM system. Results: The results of this study suggested that the slightly modified AAA real-ear measurement procedures resulted in a valid fitting of one FM system on children with normal hearing. On average, prescriptive targets were met for 1000, 2000, 3000, and 4000 Hz within 3 dB, and maximum output of the FM system never exceeded and was significantly lower than predicted uncomfortable loudness levels for the children. There was a minimal change in the real-ear unaided response when the open-ear FM receiver was placed into the ear. Use of the FM system on one or both ears resulted in significantly better speech recognition in noise relative to a no-FM condition, and the unilateral and bilateral FM receivers resulted in a comfortably loud signal when listening in background noise. Conclusions: Real-ear measures are critical for obtaining an appropriate fit of an FM system on children with normal hearing.


2011 ◽  
Vol 22 (06) ◽  
pp. 375-386 ◽  
Author(s):  
Stella L. Ng ◽  
Christine N. Meston ◽  
Susan D. Scollie ◽  
Richard C. Seewald

Background: There is a need for objective pediatric hearing aid outcome measurement and thus a need for the evaluation of outcome measures. We explored a commercially available pediatric sentence-in-noise measure adapted for use as an aided outcome measure. Purpose: The purposes of the current study were (1) to administer an adapted BKB-SIN (Bamford-Kowal-Bench Speech-in-Noise test) to adults and children who have normal hearing and children who use hearing aids and (2) to evaluate the utility of this adapted BKB-SIN as an aided, within-subjects outcome measure for amplification strategies. Research Design: We used a mixed within and between groups design to evaluate speech recognition in noise for the three groups of participants. The children who use hearing aids were tested under the omnidirectional, directional, and digital noise reduction (DNR) conditions. Results from each group were compared to each other, and we compared results of each aided condition for the children who use hearing aids to evaluate the test utility as an aided outcome measure. Study Sample: The study sample consisted of 14 adults with normal hearing (aged 22–28 yr) and 15 children with normal hearing (aged 6–18 yr), recruited through word of mouth, and 14 children who use hearing aids (aged 9–16 yr) recruited from local audiology clinics. Data Collection and Analysis: List pairs of the BKB-SIN test were presented at 50 dB HL as follows: four list pairs to each participant with normal hearing, four list pairs in the omnidirectional condition, and two list pairs in the directional and DNR conditions. Children who use hearing aids were fitted bilaterally with laboratory devices and completed the BKB-SIN test aided. Data were plotted as mean percent of key words correct at each signal-to-noise ratio (SNR). Further, we conducted an analysis of variance for group differences and within-groups for the three aided conditions. Results: Adult participants outperformed children with normal hearing, who outperformed the children who use hearing aids. SNR-50 (signal-to-noise ratio at which listener can obtain a speech recognition score of 50% correct) scores demonstrated reliability of the adapted test implementation. The BKB-SIN test measured significant differences in performance for omnidirectional versus directional microphone conditions but not between omnidirectional and DNR conditions. Conclusions: We conclude that the adapted implementation of the BKB-SIN test can be administered reliably and feasibly. Further study is warranted to develop norms for the adapted implementation as well as to determine if an adapted implementation can be sensitive to age effects. Until such norms are developed, clinicians should refrain from comparing results from the adapted test to the test manual norms and should instead use the adapted implementation as a within-subject measure.


1995 ◽  
Vol 38 (5) ◽  
pp. 1150-1156 ◽  
Author(s):  
Sandra Gordon-Salant ◽  
Peter J. Fitzgibbons

This study investigated the hypothesis that age effects exert an increased influence on speech recognition performance as the number of acoustic degradations Of the speech signal increases. Four groups participated: young listeners with normal hearing, elderly listeners with normal hearing, young listeners with hearing loss, and elderly listeners with hearing loss. Recognition was assessed for sentence materials degraded by noise, reverberation, or time compression, either in isolation or in binary combinations. Performance scores were converted to an equivalent signal-to-noise ratio index to facilitate direct comparison of the effects of different forms of stimulus degradation. Age effects were observed primarily in multiple degradation conditions featuring time compression of the stimuli. These results are discussed in terms of a postulated change in functional signal-to-noise ratio with increasing age.


2004 ◽  
Vol 116 (4) ◽  
pp. 2395-2405 ◽  
Author(s):  
Mead C. Killion ◽  
Patricia A. Niquette ◽  
Gail I. Gudmundsen ◽  
Lawrence J. Revit ◽  
Shilpi Banerjee

2019 ◽  
Vol 28 (1) ◽  
pp. 101-113 ◽  
Author(s):  
Jenna M. Browning ◽  
Emily Buss ◽  
Mary Flaherty ◽  
Tim Vallier ◽  
Lori J. Leibold

Purpose The purpose of this study was to evaluate speech-in-noise and speech-in-speech recognition associated with activation of a fully adaptive directional hearing aid algorithm in children with mild to severe bilateral sensory/neural hearing loss. Method Fourteen children (5–14 years old) who are hard of hearing participated in this study. Participants wore laboratory hearing aids. Open-set word recognition thresholds were measured adaptively for 2 hearing aid settings: (a) omnidirectional (OMNI) and (b) fully adaptive directionality. Each hearing aid setting was evaluated in 3 listening conditions. Fourteen children with normal hearing served as age-matched controls. Results Children who are hard of hearing required a more advantageous signal-to-noise ratio than children with normal hearing to achieve comparable performance in all 3 conditions. For children who are hard of hearing, the average improvement in signal-to-noise ratio when comparing fully adaptive directionality to OMNI was 4.0 dB in noise, regardless of target location. Children performed similarly with fully adaptive directionality and OMNI settings in the presence of the speech maskers. Conclusions Compared to OMNI, fully adaptive directionality improved speech recognition in steady noise for children who are hard of hearing, even when they were not facing the target source. This algorithm did not affect speech recognition when the background noise was speech. Although the use of hearing aids with fully adaptive directionality is not proposed as a substitute for remote microphone systems, it appears to offer several advantages over fixed directionality, because it does not depend on children facing the target talker and provides access to multiple talkers within the environment. Additional experiments are required to further evaluate children's performance under a variety of spatial configurations in the presence of both noise and speech maskers.


2017 ◽  
Vol 2017 ◽  
pp. 1-9 ◽  
Author(s):  
Rodmonga Potapova ◽  
Maria Grigorieva

This paper discusses the results of the pilot experimental research dedicated to speech recognition and perception of the semantic content of the utterances in noisy environment. The experiment included perceptual-auditory analysis of words and phrases in Russian and German (in comparison) in the same noisy environment: various (pink and white) types of noise with various levels of signal-to-noise ratio. The statistical analysis showed that intelligibility and perception of the speech in noisy environment are influenced not only by noise type and its signal-to-noise ratio, but also by some linguistic and extralinguistic factors, such as the existing redundancy of a particular language at various levels of linguistic structure, changes in the acoustic characteristics of the speaker while switching from one language to another one, the level of speaker and listener’s proficiency in a specific language, and acoustic characteristics of the speaker’s voice.


Sign in / Sign up

Export Citation Format

Share Document