There Is No Way That the Cancer Detection Rate for Full-Field Digital Mammography Is the Same as for Digital Breast Tomosynthesis

2019 ◽  
Vol 213 (1) ◽  
pp. W46-W46 ◽  
Author(s):  
Daniel B. Kopans
2014 ◽  
Vol 2014 ◽  
pp. 1-8 ◽  
Author(s):  
L. Margolies ◽  
A. Cohen ◽  
E. Sonnenblick ◽  
J. Mandeli ◽  
P. H. Schmidt ◽  
...  

Objectives. To study factors that predict changes in management with digital breast tomosynthesis (DBT). Methods. The Institutional Review Board approved this HIPAA compliant study. 996 patients had DBT with full field digital mammography (FFDM). Univariate analysis evaluated predictors of management change and cancer detection. Results. DBT changed management in 109 of 996 (11%); 77 (71%) required less imaging. Recalled patients after abnormal FFDM screen were most likely to have management change—25% (24 of 97 patients) compared to 8% (13/163) of symptomatic patients and 10% (72/736) of screening patients (P<0.001). Dense breasted patients had a higher likelihood of having DBT change management: 13% (68/526) compared to 9% (41/470) (P=0.03). Of the 996 patients, 19 (2%) were diagnosed with breast cancer. 15 cancers (83%) were seen on FFDM and DBT; 3 (17%) were diagnosed after DBT (0.3%, 95%CI: 0.1–0.9%). One recurrence was in the skin and was not seen on DBT nor was it seen on FFDM. The increase in cancer detection rate was 17% for asymptomatic patients, 0% for symptomatic patients, and 100% for recalled patients. Conclusions. DBT increased cancer detection rate by 20% and decreased the recall rate in 8–25%. Advances in Knowledge. DBT led to a doubling of the cancer detection rate in recalled patients.


2021 ◽  
Vol 74 (4) ◽  
pp. 842-848
Author(s):  
Andrii V. Gurando ◽  
Tetiana M. Babkina ◽  
Iryna M. Dykan ◽  
Tetiana M. Kozarenko ◽  
Viacheslav R. Gurando ◽  
...  

The aim: Comparing sensitivity and specificity of digital breast tomosynthesis and full-field digital mammography in breast cancer detection associated with four different types of asymmetries according to BI-RADS Atlas. Materials and methods: Study included 201 patients with four types of asymmetries according BI-RADS atlas (asymmetry – 81 (40,3%), focal asymmetry – 82 (40,8%), global asymmetry – 36 (17,9%) and developing asymmetry – 2 (1,0%)) who underwent full-field digital mammography, digital breast tomosynthesis and hand-held full breast ultrasound from January 2017 to June 2018. The general rate of breast cancer for the 201 patients with asymmetries was 8 cases (4,0%) (IBC, n=6 (3,0%); DCIS, n=2 (1,0%) other findings associated with asymmetries were non-malignant, n=10 (5,0%) (sclerosing adenosis, n=5 (2,5%); fibroadenomatosis, n=3 (1,5%); simple cyst, n=1 (0,5%); radial scar associated with papilloma, typical ductal hyperplasia and sclerosing adenosis, n=1 (0,5%). Results: Analysis of the results showed that sensitivity of digital breast tomosynthesis was 75.0% [95% CI, 34.91% to 96.81%] and specificity was 94.8% [95% CI, 90.68% to 97.49%] which was superior to full-field digital mammography sensitivity 50.0% [95% CI, 15.70% to 84.30%] and specificity 91.19% [95% CI, 86.27% to 94.78%] for breast cancer detection associated with different types of asymmetries. Conclusions: Using of digital breast tomosynthesis in assessment of breast asymmetries can improve sensitivity and specificity in breast cancer detection and reduce number of unnecessary biopsies and short-interval follow-up examinations.


Sign in / Sign up

Export Citation Format

Share Document