Thin-Layer Chromatographic Analysis of Phospholipids in Echinostoma revolutum (Trematoda) Adults

1979 ◽  
Vol 65 (2) ◽  
pp. 243 ◽  
Author(s):  
Bernard Fried ◽  
Irwin L. Shapiro

Parasitology ◽  
1982 ◽  
Vol 84 (2) ◽  
pp. 375-380 ◽  
Author(s):  
B. Fried ◽  
D. A. Leiby

SUMMARYIntraspecific pairing of Haematoloechus medioplexus and Echinostoma revolutum adults and interspecific pairing of H. medioplexus and E. revoltum adults were studied in vitro at 21 ± 1 °C and 30 ± 1 °C in Petri-dish cultures containing an agar substrate and a Locke's 1:1 solution overlay. Salinity and temperature tolerance tests showed that both species survived for 24 h in a Locke's 1:1 solution at 21 ± 1 °C and 30 ±1 °C. For behaviour studies, worms were placed 2 cm apart and then observed at various intervals from 5 min to 4 h. H. medioplexus and E. revolutum showed significant intraspecific pairing at 30±1 °C, whereas only H. medioplexus paired significantly at 21±1°C. Significant interspecific pairing of H. medioplexus and E. revolutum occurred at 21 ±1 °C and 30 ±1 °C. Thin-layer chromatographic analysis showed that H. medioplexus adults released mainly free sterol, along with traces of triacylglycerols and free fatty acids into a non-nutrient medium.







1990 ◽  
Vol 511 ◽  
pp. 396-401 ◽  
Author(s):  
Emilia Menziani ◽  
Barbara Tosi ◽  
Angelo Bonora ◽  
Pierluigi Reschiglian ◽  
Gaetano Lodi


2008 ◽  
Vol 91 (5) ◽  
pp. 1210-1217 ◽  
Author(s):  
Yongde Yue ◽  
Rong Zhang ◽  
Wei Fan ◽  
Feng Tang

Abstract The separation of 9 organophosphates (monocrotophos, quinalphos, triazophos, parathion-methyl, isofenphos-methyl, temephos, parathion, phoxim-ethyl, and chlorpyrifos) by high-performance thin-layer chromatography (HPTLC) with automated multiple development was studied. The HPTLC method was developed and validated for analysis of residues of phoxim-ethyl and chlorpyrifos in tea. The sample was extracted with acetonitrile and cleaned up by ENVI-CARB solid-phase extraction. The extract was directly applied as bands to glass-backed silica gel 60F254 HPTLC plates. The plates were developed with dichloromethanehexane (1 1, v/v) in a glass twin-trough chamber. Evaluation of the developed HPTLC plates was performed densitometrically. The results indicated that the detection limits of phoxim and chlorpyrifos were 5.0 109 and 1.0 108 g, respectively. Recoveries of the pesticides from tea by this analytical method were 90.7105.5%, and relative standard deviations were 7.313.5%. The precision and accuracy of the method were generally satisfactory for analysis of pesticide residues in tea.



Sign in / Sign up

Export Citation Format

Share Document