scholarly journals A Study on Plaque Removal Effect Using A Newly Developed Ultrasonic Interdental Brush.

Author(s):  
Yutaka Osada ◽  
Kazunari Matoba
Author(s):  
Qiuwen Chen ◽  
Yanjun Ge ◽  
Jinyou Chai ◽  
Hailan Feng ◽  
Jianzhang Liu ◽  
...  

Elderly patients often find it challenging to remove plaque accumulated on the attachments of implant overdentures (IOD) using conventional cleaning instruments. Further, excessive plaque accumulation can lead to peri-implant diseases and occasionally to respiratory diseases. Therefore, here, we aimed to compare the effectiveness of waist-shaped interdental brushes (WIB) with that of straight-shaped ones (SIB) in plaque removal from the locator attachments of IOD. Twenty participants with two locator attachments retaining mandibular IOD participated in this study. After the baseline cleaning, the participants refrained from oral hygiene maintenance for 3 days. A dentist cleaned one of the attachments using the WIB and the other attachment using the SIB. The pre- and post-cleaning modified plaque index (mPLI) scores were recorded. Following another 3 days free from oral hygiene maintenance, the trained participants repeated the same cleaning procedure using the WIB and SIB. Pre- and post-cleaning mPLI scores were recorded. Regardless of the type of brush used, the post-cleaning mPLI scores were lower than the pre-cleaning ones. After the cleaning procedure, the overall mean mPLI score was lower in the WIB group than in the SIB group. The post-cleaning mPLI scores at the line-angles and on the axial surfaces of the attachments were also lower in the WIB group than in the SIB group. There was no difference in the cleaning effectiveness between the dentist and participants when they used the same type of interdental brush. The WIB was significantly more efficient in plaque removal than the SIB, especially at the line-angle sites.


Author(s):  
Kazuko KAWAHARA ◽  
Hisako SASAHARA ◽  
Kiyoko TSUJIMURA ◽  
Tatsuji YAMAMURA ◽  
Masami FUKUNAGA ◽  
...  

Author(s):  
Ji-Hyun Lee ◽  
Jin-Hee Ha

This study evaluated the effectiveness of a microcurrent toothbrush (approved by the US Food and Drug Administration [FDA]), which employs a superimposed alternating and direct electric current, named as a Proxywave® technology, similar to the intensity of the biocurrent, in plaque removal and reducing gingivitis by biofilm removal through the bioelectric effect. This study enrolled 40 volunteers with gingivitis. Dental observations were made every two weeks, before and after the use of each toothbrush. We randomly assigned participants into two groups: one group used the Proxywave® toothbrush (PB) for two weeks followed by the control toothbrush (CB) for two weeks, while the other group used the CB for two weeks followed by the PB. The participants had a two-week washout period. If the toothbrush used earlier has had an effect on the bacterial flora in the oral cavity, this is to remove this effect and return it to its previous state. During each dental visit, we recorded plaque index (PI) and gingival index (GI) scores. The PI and GI scores were significantly lower in both the PB and the CB (p < 0.05). Considering the PI, there was no significant difference between the toothbrushes on all the surfaces. Considering the GI, the PB showed a significant decrease in the interproximal surface, compared to the CB (p < 0.05). The PB showed a significant decrease in the interproximal GI and had a beneficial effect in the interproximal area where the bristles could not reach. No adverse events were observed in the participants during the clinical trial. The microcurrent toothbrush is a device that can be safely used for plaque removal.


Author(s):  
Eun-Jeong Kim ◽  
Su-Jin Han

Removal of the biofilm from the proximal space is essential for preventing periodontal disease. This study aimed to prove the association between the use of proximal cleaning devices, such as dental floss and interdental brushes, and periodontal health among nationally representative Korean adults. Data collected from the 7th National Health Nutrition Survey (KNHANES VII: 2016–2018) were used for this purpose. A total of 11,359 participants aged 19 years or older who participated in KNHANES were reviewed. The response variable was the prevalence of high CPI (CPI of 3–4), and the explanatory variables were dental floss and interdental brush. A multivariable logistic regression analysis was performed to adjust for potential confounding factors and to analyze the association between periodontal disease and proximal cleaning devices. It was found that 63.1% of the participants did not use proximal cleaning devices at all, 17.5% used dental floss alone, 11.9% used an interdental brush, and 7.5% used both. Subjects who used both dental floss and interdental brush had a high CPI rate nearly half that of all the models for those who did not. In particular, for those using dental floss, the aOR of high CPI was 0.681 in Model 1, 0.714 in Model 2, and 0.737 in Model 3. Dental hygiene products for cleaning the proximal space, such as dental floss, are essential for removing the dental biofilm as a basic tool along with toothbrushes. Teaching and explaining the need to use these devices well are important for oral health care and maintenance.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Hiroki Hihara ◽  
Ryo Tagaino ◽  
Jumpei Washio ◽  
Kittipong Laosuwan ◽  
Dimas Prasetianto Wicaksono ◽  
...  

Abstract Background Removal of oral biofilm from the oral mucosa is essential for preventing risk of respiratory and gastrointestinal infection in elderly people. Currently, no device is available which can remove oral biofilm from oral mucosa effectively and safely. Therefore, the effectiveness and safety of the Micro Scale Mist UNIT (MSM-UNIT), a newly developed dental plaque removal device utilizing high speed sprays of fine water droplets, were evaluated for biofilm removal, including the rate and surface roughness for simulated tooth surface and mucous membrane. Methods Simulated tooth and oral mucosa coated with an artificial biofilm of Streptococcus mutans were used for evaluation of effectiveness, with uncoated substrates as the controls. The MSM-UNIT and a conventional air ablation device were operated under recommended instructions. The effectiveness was evaluated from the rate of removal of the biofilm, and the safety was evaluated from the damage observed by scanning electron microscope and surface roughness. Results The biofilm removal rate of the MSM-UNIT was significantly higher than that of AIRFLOW. Little damage was observed in the area treated by the MSM-UNIT. The surface roughness of the MSM-UNIT treated area on simulated tooth surface and oral mucosa showed no significant difference to the control area. In contrast, cracks and powder were observed in the area treated by AIRFLOW. In particular, the surface roughness of the AIRFLOW treated area for Toughsilon was significantly larger than that of the control. Conclusions The MSM-UNIT could be used safely and effectively for removing biofilm not only on simulated tooth surfaces but also simulated mucous membrane. The MSM-UNIT has no harmful effect on teeth or oral mucosa, and may be used for comprehensive oral care for patients during nursing care and the perioperative period.


1988 ◽  
Vol 22 (4) ◽  
pp. 250-256 ◽  
Author(s):  
L. Holmen ◽  
M. Mejare ◽  
B. Malmgren ◽  
A. Thylstrup
Keyword(s):  

2012 ◽  
Vol 23 (3) ◽  
pp. 235-240 ◽  
Author(s):  
Fabricio B. Zanatta ◽  
Raquel P. Antoniazzi ◽  
Tatiana M. P. Pinto ◽  
Cassiano K. Rösing

The aim of this study was to compare the efficacy of dental plaque removal by brushing with and without conventional dentifrice. Twenty-four students aged 17 to 28 years participated in this randomized controlled clinical trial. Quadrants 1-3 or 2-4 were randomly allocated to the test group (brushing without dentifrice) or control group (brushing with dentifrice). After 72 h of cessation of oral hygiene, Quigley & Hein (Turesky) plaque index was assessed before and after brushing by a calibrated and blind examiner. Overtime and intergroup comparisons were performed by Student's paired sample t-test at 5% significance level. The results showed that both groups after toothbrushing presented statistically significant reductions in plaque, with no differences between them (from 3.06 ± 0.54 to 1.27 ± 0.26 versus from 3.07 ± 0.52 to 1.31 ± 0.23). A separate analysis of the buccal and lingual aspects also showed no significant differences between groups. It may be concluded that the use of a conventional dentifrice during toothbrushing does not seem to enhance plaque removal capacity.


Sign in / Sign up

Export Citation Format

Share Document