scholarly journals Determination of Phenytoin in Human Plasma by a Validated HPLC Method: Application to Therapeutic Drug Monitoring Study

2020 ◽  
Vol 59 (1) ◽  
pp. 198-227
Author(s):  
Emrah Dural ◽  
Aslı Bolayır ◽  
Burhanettin Çiğdem
Author(s):  
Emrah Dural ◽  
Seniha Çelebi ◽  
Aslı Bolayır ◽  
Burhanettin Çiğdem

The aim of this study was to develop a new, simple and reliable high performance liquid chromatography (HPLC) method for analysis of valproic acid (VPA) in human plasma and apply to it to a therapeutic drug monitoring study. Also, the relationship between plasma-VPA concentrations and the amount of VPA used by patients was aimed to be evaluated. Plasma samples (0.25 mL) were precipitated with the same volume of acetonitrile and after centrifugation, aliquots were applied to a C18 column (250 mm x 4.6 mm). Mobile phase was prepared with phosphate buffer and acetonitrile (47.5:52.5, v/v). The flow-rate was 1.2 mL/min. Accuracy was between -2.9 and 3.2% and precision was ≤6.6%. Method was specific and sensitive with a detection limit of 2.2 µg/mL and the average recovery was 94.3%. Calibration curve was linear (r2>0.9968) from 10 to 150 µg/mL. Plasma-VPA levels of the epileptic patient population (n=33) treated with VPA between 0.5 and 1.5 g/day were also determined. Patient plasma-VPA concentrations ranged from 2.9 to 166.4 µg/g/mL (56.3±38.8). High RSD% (68.8%) was observed in dose-rated plasma-VPA results. Moreover, VPA plasma levels were found to be outside the recommended treatment range in 30.3% of the patients examined. The procedure described was found to be relatively simple, precise, and applicable for routine therapeutic drug monitoring (TDM) especially in neurology clinics or in toxicology reference laboratories. The high standard deviation (SD) observed in the dose depended plasma-VPA values of the volunteers proved the importance of TDM during the use of this drug. The results showed that for rational drug use, it is important to identify individual polymorphisms in the CYP2C9, CYP2A6 and CYP2B6 subtypes responsible for VPA metabolism, and to rearrange drug doses taking these enzyme activities into account.


Drug Research ◽  
2019 ◽  
Vol 69 (06) ◽  
pp. 342-347
Author(s):  
Soha M. El-Masry ◽  
Rasha M. El-Morsi

AbstractA sensitive, specific and cost-effective HPLC method was developed for quantitative determination of carbinoxamine in human plasma using liquid chromatography with ultraviolet detection. A simple liquid–liquid extraction by ethyl acetate was used to extract carbinoxamine from human plasma. Satisfactory separation was achieved by a mobile phase consisting of 20 mM ammonium dihydrogen orthophosphate containing 0.01% triethyl amine (pH adjusted to 3 by using phosphoric acid) and acetonitrile in ratio of (75:25, v/v) at a flow rate of 0.9 mL/min on Hypersil® BDS C18 column (250×4.6 mm, 5 μm) column. The UV detector was set at 260 nm. The developed method was validated in human plasma with a lower limit of quantitation of 5 ng/mL for carbinoxamine. Linearity was demonstrated over the concentration range 5–200 ng/mL. The observed within- and between-day assay precision ranged from 1.902 to 14.90%; accuracy varied between 98.87 and 108.0%. This method can be used suitably for pharmacokinetic studies and in therapeutic drug monitoring in patients treated with carbinoxamine.


RSC Advances ◽  
2015 ◽  
Vol 5 (43) ◽  
pp. 34342-34352 ◽  
Author(s):  
Yiran Fan ◽  
Guanghu Shen ◽  
Ping Li ◽  
Xiaonan Xi ◽  
Haiting Wu ◽  
...  

An integration of sample pretreatment automation using online SPE technique could provide an easy to use, efficient, sensitive and high quality methods for TDM.


Bioanalysis ◽  
2020 ◽  
Vol 12 (14) ◽  
pp. 991-1001
Author(s):  
Yanping Guan ◽  
Xiaoxia Yu ◽  
Ying Wang ◽  
Qinhai Li ◽  
Dan Liang ◽  
...  

Aim: To optimize clinical efficacy and reduce the drug-exposure-related toxicity of linezolid, whose concentrations show wide inter-variabilities, a simple and reliable quantitative assay for therapeutic drug monitoring is necessary. Results: A UHPLC–MS/MS assay has been established for determination of linezolid in human plasma and fully validated according to the US FDA guidelines. After a simple, isotope-dilluted precipitation with methanol, the analytes were separated by a straightforward isocratic mode and the MS/MS was conducted under the ESI+ mode fitted with SRM. The calibration curves proved acceptable linearity in the range of 0.1–30.0 µg/ml. Conclusion: The present assay is currently used in routine clinical practice, being applied to therapeutic drug monitoring and helps to optimize individual dosing regimens and manage adverse effects in ICU patients.


Sign in / Sign up

Export Citation Format

Share Document