scholarly journals Effect of structural uncertainties on seismic performance of moment frame rehabilitated with steel shear wall

2020 ◽  
Vol 0 (0) ◽  
pp. 0-0
Author(s):  
Mahdiye Maddahi ◽  
Mohsen Gerami ◽  
Hosein Naderpour
2019 ◽  
Vol 2019 ◽  
pp. 1-15
Author(s):  
Yuben Zhang ◽  
Xun Zhan

Low-cycle reciprocating loading tests were carried out on a steel frame with prefabricated beam-only connected steel plate shear wall (specimen A) and a steel frame with welded beam-only connected steel plate shear wall (specimen B). The seismic performance of the two different types of steel frame-steel plate shear wall specimens was studied and the failure modes, hysteresis curve, skeleton curve, and seismic performance index, etc of two groups of specimens were obtained, together with the studies of failure characteristics, ductility, energy dissipation, and stiffness degradation of the two specimens. The results showed that the assembled steel frame-steel plate shear wall with connection joints of steel shear wall with discontinuous cover plate connected on both sides (DCPC) have good seismic performance. On the basis of no loss of seismic performance, DCPC joints can provide better energy dissipation capacity than traditional welded steel plate shear wall structures and ensure the good postearthquake repair function.


2012 ◽  
Vol 174-177 ◽  
pp. 2012-2015
Author(s):  
Xiao Long Zhou ◽  
Ying Min Li ◽  
Lin Bo Song ◽  
Qian Tan

There are two typical seismic damage characteristics to the masonry building with frame shear wall structure at first two stories, and the lateral stiffness ratio of the third storey to the second storey is one of the key factors mostly affecting the seismic performance of this kind of building. However, some factors are not considered sufficiently in current Chinese seismic codes. According to the theory of performance-based seismic design, the seismic performance of this kind of structure is analyzed in this paper by taking time-history analysis on models which with different storey stiffness ratios. The results show that when the lateral stiffness ratio controlled in a reasonable range, the upper masonry deformation can be ensured in a range of elastic roughly, and the bottom frame can be guaranteed to have sufficient deformation and energy dissipation capacity. Finally, according to the seismic performance characteristics of masonry building with frame shear wall structure at first two stories, especially the characteristics under strong earthquakes, a method of simplified calculation model for the upper masonry is discussed in this paper.


ce/papers ◽  
2021 ◽  
Vol 4 (2-4) ◽  
pp. 1910-1916
Author(s):  
Maria Ntina ◽  
Dimitrios Sophianopoulos