scholarly journals Effects of a Combination of Prone Positioning and High-Frequency Oscillatory Ventilation on Blood Gas Exchange in an Experimental Pig Model of Acute Respiratory Distress Syndrome Efekti Kombinacije Ležećeg Položaja I Oscilatorne Plućne Ventilacije Visoke Frekvencije Na Razmenu Gasova U Krvi Na Modelu Sindroma Akutnog Respiratornog Šoka Kod Svinja

2014 ◽  
Vol 64 (3) ◽  
pp. 307-318
Author(s):  
Žurek Jiří ◽  
Dominik Petr ◽  
Košut Peter ◽  
Šeda Miroslav ◽  
Fedora Michal

Abstract This animal study was conducted in order to verify the effects of combining highfrequency oscillatory ventilation and prone positioning and the order of application of both methods on blood gas exchange in an experimental model of acute respiratory distress syndrome. Forty domestic pigs were used for the study. Saline solution washout was produced by bilateral lung lavage. The lavage process was repeated until adequate impairment of gas exchange (defined as PaO2 < 100 mmHg) 60 min following the last lavage was achieved. Subsequently, lung injury was established and each model was randomized to one of five groups, with differences in the type of mechanical ventilation used (conventional mechanical ventilation in accordance with the principles of protective lung ventilation or high-frequency oscillatory ventilation) and also in the positioning of the experimental model (supine position or mode changing prone and supine positions in a ratio 18:6 hours). The best oxygenation was achieved in the group prone position + high-frequency oscillatory ventilation. The most favorable combination in terms of carbon dioxide elimination is the high-frequency oscillatory ventilation + prone position. The best results in terms of oxygenation index value were obtained in the combination of a prone position with the high-frequency oscillatory ventilation and in the prone position. In conclusion, by using combinations of prone positioning and high-frequency oscillatory ventilation, one can achieve better blood gas parameters during acute respiratory distress syndrome.

1989 ◽  
Vol 66 (3) ◽  
pp. 1343-1351 ◽  
Author(s):  
B. R. Boynton ◽  
M. D. Hammond ◽  
J. J. Fredberg ◽  
B. G. Buckley ◽  
D. Villanueva ◽  
...  

We examined the effects of oscillatory frequency (f), tidal volume (VT), and mean airway pressure (Paw) on respiratory gas exchange during high-frequency oscillatory ventilation of healthy anesthetized rabbits. Frequencies from 3 to 30 Hz, VT from 0.4 to 2.0 ml/kg body wt (approximately 20–100% of dead space volume), and Paw from 5 to 20 cmH2O were studied. As expected, both arterial partial pressure of O2 and CO2 (PaO2 and PaCO2, respectively) were found to be related to f and VT. Changing Paw had little effect on blood gas tensions. Similar values of PaO2 and PaCO2 were obtained at many different combinations of f and VT. These relationships collapsed onto a single curve when blood gas tensions were plotted as functions of f multiplied by the square of VT (f. VT2). Simultaneous tracheal and alveolar gas samples showed that the gradient for PO2 and PCO2 increased as f. VT2 decreased, indicating alveolar hypoventilation. However, venous admixture also increased as f. VT2 decreased, suggesting that ventilation-perfusion inequality must also have increased.


Sign in / Sign up

Export Citation Format

Share Document