Dynamic response of the LE-5 rocket engine liquid oxygen pump

1983 ◽  
Author(s):  
K. KAMIJO
2021 ◽  
pp. 107754632110036
Author(s):  
Shihui Huo ◽  
Hong Huang ◽  
Daoqiong Huang ◽  
Zhanyi Liu ◽  
Hui Chen

Turbo pump is one of the elements with the most complex flow of liquid rocket engine, and as an important component of turbo pump, an impeller is the weak point affecting its reliability. In this study, a noncontact modal characteristic identification technique was proposed for the liquid oxygen pump impeller. Modal characteristics of the impeller under three different submerged media, air, pure water, and brine with same density as liquid oxygen, were tested based on the noncontact modal identification technology. Submersion state directly affects the modal frequencies and damping ratio. The transient vibration response characteristics of the impeller excited by the unsteady flow field was achieved combining with unsteady flow field analysis and transient dynamic analysis in the whole flow passage of the liquid oxygen pump. Vibration responses at different positions of the impeller show 10X and 20X frequencies, and the amplitude at the root of short blade is significant, which needs to be paid more attention in structural design and fatigue evaluation.


Author(s):  
Hang Gi Lee ◽  
Ju Hyun Shin ◽  
Suk Hwan Yoon ◽  
Dae Jin Kim ◽  
Jun Hwan Bae ◽  
...  

This study investigates the behavior of a turbopump assembly during critical cavitation of the propellant pumps in the upper rocket engine of the Korea Space Launch Vehicle-II. Turbopumps operate under conditions involving low pressure at the pump inlet and high rotational speeds to allow for a lightweight design. This severe environment can easily cause cavitation to occur in the pump. This cavitation can then cause the pump operation to fail. As the cavitation number in the pump decreases below the critical point, the pump fails to operate. There is concern regarding the behavior of the turbopump assembly arising from pump failure due to cavitation. It is necessary to verify the problems that may occur if the turbopump assembly operates under extreme conditions, such like the critical cavitation. This study performed tests to investigate the breakdown of pumps in the turbopump assembly. Tests were conducted with liquid nitrogen, water, and high-pressure air instead of the mediums used during actual operation of liquid oxygen, kerosene, and hot gas. The turbopump was tested at the design point of 27,000 rpm, while the inlet pressure of each pump was controlled to approach the critical cavitation number. The turbine power output was maintained during the tests. The results show that the breakdown point of the oxidizer pump using liquid nitrogen, which is a cryogenic medium, occurred at a lower cavitation number than during an individual component suction performance test using water. The fuel pump using water, meanwhile, experiences breakdown at similar cavitation numbers in both tests. As the breakdown of the pump occurs, the power required by that pump decreases, and the rotational speed of the turbopump increases. Compared with individual pump suction performance tests, this breakdown test can be used to determine the limit of the propellant inlet pressure of the turbopump and to characterize the behavior of the turbopump assembly when a breakdown occurs. Vibrations were also analyzed for tests at a high cavitation number and at the critical cavitation number. The vibration increased with breakdown and notable frequencies were analyzed.


2019 ◽  
Vol 52 (3-4) ◽  
pp. 159-167
Author(s):  
Hong-Hua Cai ◽  
Wan-Sheng Nie ◽  
Ling-Yu Su ◽  
Tian-yi Shi ◽  
Kang-Kang Guo

Author(s):  
Ethan Sichler ◽  
Eric Gonzalez ◽  
Jesus D. Montes ◽  
Richard Picard ◽  
Frank O. Chandler

Sign in / Sign up

Export Citation Format

Share Document