scholarly journals Investigation of Dimethyl Ether Combustion Instabilities in a Partially - Premixed Gas Turbine Model Combustor Using High-Speed Laser Diagnostics

Author(s):  
Patton Allison ◽  
Yuntao Chen ◽  
James F. Driscoll
2010 ◽  
Vol 52 (3) ◽  
pp. 555-567 ◽  
Author(s):  
Isaac Boxx ◽  
Christoph M. Arndt ◽  
Campbell D. Carter ◽  
Wolfgang Meier

Author(s):  
J. D. Gounder ◽  
I. Boxx ◽  
P. Kutne ◽  
F. Biagioli ◽  
H. Luebcke

Gas turbine (GT) flames at lean operating conditions are susceptible to instabilities that can lead to unsteady operation, flame extinction, and thermoacoustic oscillations. High speed (10 kHz) laser and optical diagnostic techniques have been used to investigate the effect of fuel staging on the mechanisms involved in such instabilities and the overall performance of a gas turbine model combustor. The GT burner used in this study consists of coaxial swirlers which allow for fuel staging capability, where the fuel is varied from 100% to 20% fuel injection in the inner swirler. The burner is equipped with a combustion chamber with large quartz windows, allowing for the application of optical and laser diagnostics. Simultaneous high speed OH Planar Laser Induced Fluorescence (PLIF) and OH* chemiluminescence (CL) imaging, exhaust gas sampling and acoustic measurements were applied to characterize the flames and determine the operability limits of the combustor. Methane air flames at atmospheric pressure have been investigated at a constant thermal power of 58 kW. The global equivalence ratio was kept constant, while the fuel staging was varied. The bulk flow velocity at the exit plane was kept constant at 20 m/s. Simultaneous high speed particle image velocity (PIV) and OH PLIF measurements were performed at a repetition rate of 10 kHz on specifically chosen flames with a fixed staging and equivalence ratio. This paper will present the flame and the flow field structure resolved using the kHz measurement technique. The interaction between the velocity field and the flame front marked by the OH LIF will be presented. The mean PIV image provides the location of the inner and outer recirculation zones. The flame structure presented in this paper will also show the effectiveness of fuel mixing as the staging is varied. The changes in flame shape with variation in fuel staging is determined using the OH* chemiluminescence images. As the fuel flow in the inner swirler is reduced, the NOx and CO emissions also reduce and reach a minimum at a staging of 45% fuel being injected in the inner swirler. As fuel injection in the outer swirler increases beyond 60% the NOx and CO emissions start also increasing.


Author(s):  
Matthias Utschick ◽  
Daniel Eiringhaus ◽  
Christian Köhler ◽  
Thomas Sattelmayer

This study investigates the influence of the fuel injection strategy on safety against flashback in a gas turbine model combustor with premixing of H2-air-mixtures. The flashback propensity is quantified and the flashback mechanism is identified experimentally. The A2EV swirler concept exhibits a hollow, thick walled conical structure with four tangential slots. Four fuel injector geometries were tested. One of them injects the fuel orthogonal to the air flow in the slots (jet-in-crossflow-injector, JICI). Three injector types introduce the fuel almost isokinetic to the air flow at the trailing edge of the swirler slots (trailing edge injector, TEI). Velocity and mixing fields in mixing zone and combustion chamber in isothermal water flow were measured with High-speed-Particle-Image-Velocimetry (PIV) and Highspeed-Laser-Induced-Fluorescence (LIF). The flashback limit was determined under atmospheric pressure for three air mass flows and 673 K preheat temperature for H2-air-mixtures. Flashback mechanism and trajectory of the flame tip during flashback were identified with two stereoscopically oriented intensified high-speed cameras observing the OH* radiation. We notice flashback in the core flow due to Combustion Induced Vortex Breakdown (CIVB) and Turbulent upstream Flame Propagation (TFP) near the wall dependent on the injector type. The Flashback Resistance (FBR) defined as the ratio between a characteristic flow speed and a characteristic flame speed measures the direction of propagation of a turbulent flame in the flow field. Although CIVB cannot be predicted solely based on the FBR, its distribution gives evidence for CIVB-prone states. The fuel should be injected preferably isokinetic to the air flow along the entire trailing edge in oder to reduce the RMS fluctuation of velocity and fuel concentration. The characteristic velocity in the entire cross section of the combustion chamber inlet should be at least twice the characteristic flame speed. The position of the stagnation point should be tuned to be located in the combustion chamber by adjusting the axial momentum. Those measures lead to safe operation with highly reactive fuels at high equivalence ratios.


Author(s):  
Klaus Peter Geigle ◽  
Jochen Zerbs ◽  
Markus Köhler ◽  
Michael Stöhr ◽  
Wolfgang Meier

Sooting ethylene/air flames were investigated experimentally in a dual swirl gas turbine model combustor with good optical access at atmospheric pressure. The goals of the investigations were a detailed characterization of the soot formation and oxidation processes under gas turbine relevant conditions and the establishment of a data base for the validation of numerical combustion simulations. The flow field was measured by stereoscopic particle image velocimetry, the soot volume fractions by laser-induced incandescence, the heat release by OH chemiluminescence imaging and the temperatures by coherent anti-Stokes Raman scattering. Two flames are compared: a fuel-rich partially premixed flame with moderate soot concentrations and a second one with the same parameters but additional injection of secondary air. Instantaneous as well as average distributions of the measured quantities are presented and discussed. The measured soot distributions exhibit a high temporal and spatial dynamic. This behavior correlates with broad temperature probability density functions. With injection of secondary air downstream of the flame zone the distributions change drastically. The data set, including PDFs of soot concentration, temperature and flow velocity, is unique in combining different laser diagnostics with a combustor exhibiting a more challenging geometry than existing validation experiments.


Sign in / Sign up

Export Citation Format

Share Document