Minimally invasive technique for peri-implant soft tissue augmentation – case series

Author(s):  
Rocha Salomao
2020 ◽  
Vol 14 (3) ◽  
pp. 269-273
Author(s):  
Vinicius Oliveira ◽  
Sérgio Prata

Objective: To assess the degree of postoperative satisfaction of patients with acute Achilles tendon rupture who underwent surgical reconstruction by a minimally invasive technique using Tenolig®. Methods: A retrospective observational study was conducted with 18 patients with acute Achilles tendon rupture diagnosed by a positive Thompson test who underwent surgery. Outcomes were assessed using the American  arthopaedic Foot and Ankle Society (AOFAS) score and the Foot Function Index (FFI). Furthermore, quantitative variables were descriptively treated, and patients’ age was correlated with FII and AOFAS score using Spearman’s correlation coefficient at a significance level of 5%. Results: Patients underwent surgery from one to six days after injury and were discharged one day later. Only one patient had a superficial postoperative infection. Patients’ AOFAS scores ranged from 75 to 100 points, and FFI ranged from 0 to 20%. The patient withsuperficial postoperative infection had an AOFAS score and a FFI of 75 points and 20%, respectively. Conclusion: Percutaneous repair of complete Achilles tendon rupture with Tenolig® resulted in high functional scores and a low rate of complications. Level of Evidence IV; Therapeutic Studies; Case Series.


2020 ◽  
Vol 65 (No. 2) ◽  
pp. 49-55
Author(s):  
S Manfredi ◽  
G Covi ◽  
M Bonazzi ◽  
G Gnudi ◽  
M Fumeo ◽  
...  

Foreign bodies (FBs) retained in the subcutaneous tissues are a common reason for medical consultation. In small animals, FBs usually consist of vegetal materials, especially grass awns. Failure to remove the FBs is likely to give rise to acute or late complications. The surgical removal of the FBs can be invasive, costly and technically challenging. Ultrasound has become a mainstay in the detection of FBs and it can be used to guide the extraction of the FBs with a minimally invasive technique. This study describes the detection and extraction of soft-tissue FBs in small animals. One hundred-sixty-two patients, presenting at two veterinary clinics with suspected FBs retained in the soft tissues of various body districts, were considered. Once an ultrasound diagnosis was established, the ultrasound-guided removal of the FB was performed. A high-frequency linear transducer, a skin disinfection, sedation or anaesthesia was used when needed and a scalpel and some Hartmann forceps were also used. One hundred-eighty-two FBs were successfully removed in all the patients. In six cases, the FB was identified during a second ultrasonographic examination, after recurrence of the fistula. No complications were reported after the procedure. The extraction of the FB was performed in an echographic suite in 138 cases and in a surgery room with surgical intervention in 24 cases. In the latter situation, the surgical minimally invasive dissection of tissues under ultrasound guidance was performed before the removal of the FB. In conclusion, the ultrasound-guided removal of the FBs retained in the superficial soft tissue can be considered a good alternative to surgery. However, failure to remove a FB does not preclude the removal by traditional surgery.


Author(s):  
RICARDO RAMON CAMACHO IRIGOYEN ◽  
RAFAEL DE LUCA DE-LUCENA ◽  
JEAN KLAY SANTOS MACHADO ◽  
GABRIEL SEVERO DA-SILVA ◽  
CARLOS ROBERTO SCHWARTSMANN ◽  
...  

ABSTRACT Introduction: the number of hip fractures is estimated to increase from 1.66 million in 1990 to 6.26 million by 2050. Internal fixation is the most common surgical treatment for intertrochanteric fractures. Objectives: the objective of the present research is to describe a minimally invasive technique with a modified instrument for the treatment of stable proximal femoral trochanteric fractures using the standard DHS, classified as Tronzo types 1 and 2 (AO 31A1.2), and presenting a case series. Methods: a case was selected to present the technique. Patients operated by this technique undergo a clinical evaluation and preoperative preparation as routine. The criteria for inclusion in the study were the presence of stable fracture of the proximal femur verified by two hip specialist orthopedists, and operated by the minimally invasive technique with a modified instrument using a standard DHS. Exclusion criteria were cases of patients operated for unstable fractures, and the use of other surgical techniques. A case series of 98 patients was performed and discussed. Results: minimally invasive technique with a modified instrument using the standard DHS device can reduce bleeding, it decreases soft tissue injuries, surgical time, and hospital stay, as any other MIPO procedures. Ninety-eight patients underwent the operation (Tronzo types I and II), 59 female and 39 male, ages from 50 to 85 years old. Immediate post-operative complications were shortening of the lower limb, loss of fracture reduction, and death by clinical complications. Conclusion: the present study describes a minimally invasive surgical technique using a modified instrument to perform proximal femoral osteosynthesis for stable trochanteric fractures, using the standard DHS.


2019 ◽  
Vol 21 (5) ◽  
pp. 923-930 ◽  
Author(s):  
Kai R. Fischer ◽  
Tiziano Testori ◽  
Hannes Wachtel ◽  
Sven Mühlemann ◽  
Arndt Happe ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document