scholarly journals Spectrophotometric Determination of Metoclopramide Hydrochloride in Pharmaceutical Preparations Via Schiff ’s Base Reaction

2021 ◽  
Author(s):  
Rabee Ali ◽  
Nabeel Othman
1997 ◽  
Vol 30 (15) ◽  
pp. 2743-2753 ◽  
Author(s):  
M. S. Rizk ◽  
Y M Issa ◽  
A F Shoukry ◽  
E M Atia

2006 ◽  
Vol 70 (3) ◽  
pp. 259-262 ◽  
Author(s):  
T SAFFAJ ◽  
M CHARROUF ◽  
A ABOURRICHE ◽  
Y ABOUD ◽  
A BENNAMARA ◽  
...  

2015 ◽  
Vol 12 (1) ◽  
pp. 167-177 ◽  
Author(s):  
Baghdad Science Journal

A spectrophotometric method has been proposed for the determination of two drugs containing phenol group [phenylephrine hydrochloride (PHP) and salbutamol sulphate (SLB)] in pharmaceutical dosage forms. The method is based on the diazotization reaction of metoclopramide hydrochloride (MCP) and coupling of the diazotized reagent with drugs in alkaline medium to give intense orange colored product (?max at 470 nm for each of PHP and SLB). Variable parameters such as temperature, reaction time and concentration of the reactants have been analyzed and optimized. Under the proposed optimum condition, Beer’s law was obeyed in the concentration range of 1-32 and 1-14 ?g mL-1 for PHP and SLB, respectively. The limit of detection (LOD) and limit of quantification (LOQ) for each of PHP and SLB were 0.60, 0.52 ?g mL-1 and 2.02, 1.72 ?g mL-1, respectively. No interference was observed from common excipients present in pharmaceutical preparations. The good correlation coefficients and low relative standard deviation assert the applicability of this method. The suggested method was further applied for the determinations of drugs in commercial pharmaceutical preparations, which was compared statistically with reference methods by means of t- test and F- test and were found not to differ significantly at 95% confidence level. The procedure was characterized by its simplicity with accuracy and precision.


2011 ◽  
Vol 8 (1) ◽  
pp. 110-117 ◽  
Author(s):  
Baghdad Science Journal

A simple, accurate and sensitive spectrophotometric method for the determinaion of epinephrine is described . The method is based on the coordination of Pr (III) with epinephrine at pH 6. Absorbance of the resulting orange yellow complex is measured at 482 nm . A graph of absorbance versus concentrations shows that beer 's low is obeyed over the concentration range (1-50)mg.ml-1 of epinephrine with molar absorpitivity of ( 2.180x103 L.mol-1.cm-1 ), a sandell sensitivity of (0.084 mg.cm-2 ), a relative error of (-2.83%) , a corrolation coffecient (r= 0.9989) and recovery % ( 97.03 ± 0.75 ) depending on the concentration.This method is applied to analyse EP in several commercially available pharmaceutical preparations using direct methods .All statistical calculations are implemented via a Minitab software version 11.


Sign in / Sign up

Export Citation Format

Share Document