limit of quantification
Recently Published Documents


TOTAL DOCUMENTS

1512
(FIVE YEARS 847)

H-INDEX

40
(FIVE YEARS 8)

2022 ◽  
Vol 9 (1) ◽  
Author(s):  
Fumikatsu Nohara ◽  
Go Tajima ◽  
Hideo Sasai ◽  
Yoshio Makita

AbstractMedium-chain acyl-coenzyme A dehydrogenase (MCAD) deficiency is an autosomal recessive disease caused by biallelic pathogenic ACADM variants. We report a case of an asymptomatic Japanese girl with MCAD deficiency caused by compound heterozygous pathogenic variants (NM_000016.5:c.1040G > T (p.Gly347Val) and c.449_452delCTGA (p.Thr150ArgfsTer4)). Because the MCAD residual activity in lymphocytes of the patient was below the limit of quantification, both variants are likely to cause complete loss of MCAD enzymatic activity.


Toxins ◽  
2022 ◽  
Vol 14 (1) ◽  
pp. 61
Author(s):  
Wannes Hugo R. Van Hassel ◽  
Mirjana Andjelkovic ◽  
Benoit Durieu ◽  
Viviana Almanza Marroquin ◽  
Julien Masquelier ◽  
...  

In the context of increasing occurrences of toxic cyanobacterial blooms worldwide, their monitoring in Belgium is currently performed by regional environmental agencies (in two of three regions) using different protocols and is restricted to some selected recreational ponds and lakes. Therefore, a global assessment based on the comparison of existing datasets is not possible. For this study, 79 water samples from a monitoring of five lakes in Wallonia and occasional blooms in Flanders and Brussels, including a canal, were analyzed. A Liquid Chromatography with tandem mass spectrometry (LC-MS/MS) method allowed to detect and quantify eight microcystin congeners. The mcyE gene was detected using PCR, while dominant cyanobacterial species were identified using 16S RNA amplification and direct sequencing. The cyanobacterial diversity for two water samples was characterized with amplicon sequencing. Microcystins were detected above limit of quantification (LOQ) in 68 water samples, and the World Health Organization (WHO) recommended guideline value for microcystins in recreational water (24 µg L−1) was surpassed in 18 samples. The microcystin concentrations ranged from 0.11 µg L−1 to 2798.81 µg L−1 total microcystin. For 45 samples, the dominance of the genera Microcystis sp., Dolichospermum sp., Aphanizomenon sp., Cyanobium/Synechococcus sp., Planktothrix sp., Romeria sp., Cyanodictyon sp., and Phormidium sp. was shown. Moreover, the mcyE gene was detected in 75.71% of all the water samples.


Molecules ◽  
2022 ◽  
Vol 27 (2) ◽  
pp. 543
Author(s):  
Silvia Migliari ◽  
Antonino Sammartano ◽  
Marti Boss ◽  
Martin Gotthardt ◽  
Maura Scarlattei ◽  
...  

Background: Glucagon-like peptide 1 receptor (GLP-1R) is preferentially expressed in pancreatic islets, especially in β-cells, and highly expressed in human insulinomas and gastrinomas. In recent years several GLP-1R–avid radioligands have been developed to image insulin-secreting tumors or to provide a tentative quantitative in vivo biomarker of pancreatic β-cell mass. Exendin-4, a 39-amino acid peptide with high binding affinity to GLP-1R, has been labeled with Ga-68 for imaging with positron emission tomography (PET). Preparation conditions may influence the quality and in vivo behavior of tracers. Starting from a published synthesis and quality controls (QCs) procedure, we have developed and validated a new rapid and simple UV-Radio-HPLC method to test the chemical and radiochemical purity of [68Ga]Ga-NODAGA-exendin-4, to be used in the clinical routine. Methods: Ga-68 was obtained from a 68Ge/68Ga Generator (GalliaPharma®) and purified using a cationic-exchange cartridge on an automated synthesis module (Scintomics GRP®). NODAGA-exendin-4 contained in the reactor (10 µg) was reconstituted with HEPES and ascorbic acid. The reaction mixture was incubated at 100 °C. The product was purified through HLB cartridge, diluted, and sterilized. To validate the proposed UV-Radio-HPLC method, a stepwise approach was used, as defined in the guidance document released by the International Conference on Harmonization of Technical Requirements of Pharmaceuticals for Human Use (ICH), adopted by the European Medicines Agency (CMP/ICH/381/95 2014). The assessed parameters are specificity, linearity, precision (repeatability), accuracy, and limit of quantification. Therefore, a range of concentrations of Ga-NODAGA-exendin-4, NODAGA-exendin-4 (5, 4, 3.125, 1.25, 1, and 0.75 μg/mL) and [68Ga]Ga-NODAGA-exendin-4 were analyzed. To validate the entire production process, three consecutive batches of [68Ga]Ga-NODAGA-exendin-4 were tested. Results: Excellent linearity was found between 5–0.75 μg/mL for both the analytes (NODAGA-exendin-4 and 68Ga-NODAGA-exendin-4), with a correlation coefficient (R2) for calibration curves equal to 0.999, average coefficients of variation (CV%) <2% (0.45% and 0.39%) and average per cent deviation value of bias from 100%, of 0.06% and 0.04%, respectively. The calibration curve for the determination of [68Ga]Ga-NODAGA-exendin-4 was linear with a R2 of 0.993 and CV% <2% (1.97%), in accordance to acceptance criteria. The intra-day and inter-day precision of our method was statistically confirmed using 10 μg of peptide. The mean radiochemical yield was 45 ± 2.4% in all the three validation batches of [68Ga]Ga-NODAGA-exendin-4. The radiochemical purity of [68Ga]Ga-NODAGA-exendin-4 was >95% (97.05%, 95.75% and 96.15%) in all the three batches. Conclusions: The developed UV-Radio-HPLC method to assess the radiochemical and chemical purity of [68Ga]Ga-NODAGA-exendin-4 is rapid, accurate and reproducible like its fully automated production. It allows the routine use of this PET tracer as a diagnostic tool for PET imaging of GLP-1R expression in vivo, ensuring patient safety.


Author(s):  
Joshua N. G. Marti ◽  
Verena Kilchenmann ◽  
Christina Kast

Abstract The aim of this study was to determine residue levels of pesticides in Swiss commercial beeswax. Foundation samples were collected in 2019 from nine commercial manufacturers for analysis of 21 pesticides using ultra-high performance liquid chromatography. Individual samples showed the variability and residue ranges and pooled samples represented the average annual residue values of the Swiss production. In total, 17 pesticides were identified and 13 pesticides were quantified. They included 13 acaricides and/or insecticides, two fungicides as well as a synergist and a repellent. The means calculated from individual samples were similar to the average annual residue values for most tested pesticides. Mean values of 401, 236, 106 and 3 μg·kg−1 were obtained for the beekeeping-associated contaminants coumaphos, tau-fluvalinate, bromopropylate and N-(2,4-Dimethylphenyl)-formamide (DMF; breakdown product of amitraz), respectively. For the other pesticides, the mean values were 203 μg·kg−1 (synergist piperonyl butoxide), 120 μg·kg−1 (repellent N,N-Diethyl-3-methylbenzamide, DEET), 19 μg·kg−1 (chlorfenvinphos) and 4 μg·kg−1 ((E)-fenpyroximate), while the means for acrinathrin, azoxystrobin, bendiocarb, boscalid, chlorpyrifos, flumethrin, permethrin, propoxur and thiacloprid were below the limit of quantification (< LOQ). Individual samples contained from seven to 14 pesticides. The ranges of values for coumaphos and piperonyl butoxide (from 14 to 4270 μg·kg−1; from 6 to 1555 μg·kg−1, respectively) were larger as compared to the ranges of values for DEET and tau-fluvalinate (from < LOQ to 585 μg·kg−1; from 16 to 572 μg·kg−1, respectively). In conclusion, the most prominent contaminants were the pesticides coumaphos and tau-fluvalinate, which are both acaricides with previous authorization for beekeeping in Switzerland, followed by piperonyl butoxide, a synergist to enhance the effect of insecticides. Graphical abstract


2022 ◽  
Vol 23 (2) ◽  
pp. 598
Author(s):  
Justyna Piechocka ◽  
Natalia Litwicka ◽  
Rafał Głowacki

It is well established that homocysteine (Hcy) and its thiolactone (HTL) are reactive towards aldehydes in an aqueous environment, forming substituted thiazinane carboxylic acids. This report provides evidence that Hcy/HTL and formaldehyde (FA) adduct, namely 1,3-thiazinane-4-carboxylic acid (TCA) is formed in vivo in humans. In order to provide definitive proof, a gas chromatography–mass spectrometry (GC–MS) based method was elaborated to identify and quantify TCA in human urine. The GC–MS assay involves chemical derivatization with isobutyl chloroformate (IBCF) in the presence of pyridine as a catalyst, followed by an ethyl acetate extraction of the obtained isobutyl derivative of TCA (TCA-IBCF). The validity of the method has been demonstrated based upon United States Food and Drug Administration recommendations. The assay linearity was observed within a 1–50 µmol L−1 range for TCA in urine, while the lowest concentration on the calibration curve was recognized as the limit of quantification (LOQ). Importantly, the method was successfully applied to urine samples delivered by apparently healthy volunteers (n = 15). The GC–MS assay may provide a new analytical tool for routine clinical analysis of the role of TCA in living systems in the near future.


2022 ◽  
Vol 12 (1) ◽  
Author(s):  
Małgorzata Kowalska ◽  
Magdalena Woźniak ◽  
Michał Kijek ◽  
Paulina Mitrosz ◽  
Jerzy Szakiel ◽  
...  

AbstractThe work mainly focused on a validation of the method for determining the content of salicylic acid and individual unknown impurities in new pharmaceutical product—tablets containing: 75, 100 or 150 mg of acetylsalicylic acid and glycine in the amount of 40 mg for each dosage. The separation of the components was carried out by means of HPLC, using a Waters Symmetry C18 column (4.6 × 250 mm, 5 μm) as the stationary phase. The mobile phase consisted of a mixture of 85% orthophosphoric acid, acetonitrile and purified water (2:400:600 V/V/V). Detection was carried out at a wavelength of 237 nm, with a constant flow rate of 1.0 ml min−1. In order to verify the method, linearity, precision (repeatability and reproducibility), accuracy, specificity, range, robustness, system precision, stability of the test and standard solution, limit of quantification and forced degradation were determined. Validation tests were performed in accordance with ICH (International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use) guidelines. The method was validated successfully. It was confirmed that the method in a tested range of 0.005–0.40% salicylic acid with respect to acetylsalicylic acid content is linear, precise and accurate.


Micromachines ◽  
2022 ◽  
Vol 13 (1) ◽  
pp. 88
Author(s):  
Mahboobeh Shahsavari ◽  
Mojtaba Mortazavi ◽  
Somayeh Tajik ◽  
Iran Sheikhshoaie ◽  
Hadi Beitollahi

In this study, we prepared graphene oxide (GO)/ZIF-67 nanocomposites. Therefore, GO/ZIF-67 nanocomposites were used as a modifier on a screen-printed electrode (GO/ZIF-67/SPE) for studying the electrochemical behavior of epinine in phosphate buffer saline (PBS) at pH 7.0 with voltammetry techniques. The GO/ZIF-67/SPE showed greater electrocatalytic activities than the bare SPE. As a result, the GO/ZIF-67/SPE was utilized for additional electrochemical examinations. The epinine concentration determination was in the range 9.0 × 10−8 M to 5.0 × 10−4 M, and the limit of detection (LOD) as well as the limit of quantification (LOQ) equaled 2.0 and 6.6 nM, respectively. From the scan rate study, the oxidation of epinine was found to be diffusion-controlled, and the simultaneous detection of epinine and dobutamine were well achieved with the differential pulse voltammetric (DPV) technique. Moreover, the stability and reproducibility of epinine at the GO/ZIF-67/SPE was studied, and the use of the GO/ZIF-67/SPE to detect epinine and dobutamine in real samples was furthermore successfully demonstrated.


2022 ◽  
Author(s):  
Guruprasad R Medigeshi ◽  
Gaurav Batra ◽  
Deepika Rathna Murugesan ◽  
Ramachandran Thiruvengadam ◽  
Souvick Chattopadhyay ◽  
...  

Background: Rapid expansion of the omicron SARS-CoV-2 variant of concern despite extensive vaccine coverage might be related to decreased neutralising ability of vaccine induced antibodies. The neutralising ability of different vaccines with or without natural SARS-CoV-2 infection against omicron is however not well known. Methods: We tested the ability of vaccine and natural infection induced antibodies to neutralise omicron variant in a live virus neutralisation assay. Four groups of individuals were included: (i) complete vaccination with ChAdOx1 nCoV-19 (n=20), (ii) complete vaccination with ChAdOx1 nCoV-19 plus prior SARS-CoV-2 infection during the delta variant driven surge (n=20), (iii) complete vaccination with inactivated whole virus vaccine (BBV152) (n=20), (iv) complete vaccination with BBV152 plus prior SARS-CoV-2 infection (n=20). Primary outcome was fold-change in the virus neutralisation ability of plasma against the omicron variant compared with ancestral and delta variant. Findings: The neutralisation geometric mean titre (GMT) was 384 (95% CI: 662, 223) against the ancestral virus with BBV152 vaccination alone and 383 (95% CI: 709, 207) with ChAdOx1 nCov-19 vaccination alone. The corresponding values for hybrid immunity groups were 795 (95% CI: 1302, 486) and 1424 (95% CI: 2581,786) respectively. Against the omicron variant, only 5 out of 20 in both BBV152 and ChAdOx1 nCoV-19 vaccine only groups, 5 out of 19 in BBV152 plus SARS-CoV-2 infection group, and 9 out of 20 in ChAdOx1 nCoV-19 plus SARS-CoV-2 infection group exhibited neutralisation titres above the lower limit of quantification (1:20). The 50% neutralization titre against ancestral strain and omicron demonstrated strong correlation with anti-RBD IgG levels [Pearson r: 0.94 (0.91, 0.96) p: <0.001 and 0.92 (0.88, 0.95) p:<0.001 respectively]. Interpretation: Omicron variant shows significant reduction in neutralising ability of both vaccine induced and hybrid immunity induced antibodies which might explain immune escape and high transmission even in the presence of widespread vaccine coverage.


2022 ◽  
Vol 2022 ◽  
pp. 1-7
Author(s):  
Huiting Sun ◽  
Han Xing ◽  
Xueke Tian ◽  
Xiaojian Zhang ◽  
Jing Yang ◽  
...  

Pharmacokinetics/pharmacodynamics is the foundation for guiding the rational application of antibiotics in clinical practice, so it is necessary to establish quantitative methods for accurate drug concentration determination. This study aimed to develop a rapid and simple ultrahigh-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for simultaneous quantification of 14 antibiotics (amikacin, etimicin, ceftazidime, cefepime, cefoperazone, ceftriaxone, daptomycin, latamoxef, linezolid, meropenem, biapenem, ampicillin, norvancomycin, and vancomycin) in human plasma and cerebrospinal fluid. Antibiotics were chromatographically separated on a Waters ACQUITY UPLC BEH C18 column (2.1 mm × 50 mm, 1.7 μm) via gradient elution within 3 minutes and were monitored using positive ion fitted with multiple reaction monitoring. The lower limit of quantification was 0.05–2.0 μg·mL−1. The method was verified according to the FDA bioanalysis method validation guidelines, which showed excellent accuracy (from 86.75% to 110.85%) and precision (from 0.46% to 10.97%). At last, this method was successfully applied to therapeutic drug monitoring in 113 patients under antibiotics treatment.


2022 ◽  
Author(s):  
Samir Malhotra ◽  
Dang Song Pham ◽  
Michael P.H. Lau ◽  
Anh H. Nguyen ◽  
Hung Cao

Detection of bacterial pathogens is significant in the fields of food safety, medicine, public health, etc. If bacterial pathogens are not treated promptly, antimicrobial resistance is possible and can lead to morbidity and mortality. Current bacterial detection methodologies rely on laboratory-based techniques that pose limitations such as long turnaround detection times, expensive costs, in-adequate accuracy, and required trained specialists. Here, we describe a cost-effective and port-able 3D-printed electrochemical biosensor that facilitates rapid detection of certain Escherichia coli (E. coli) strains (DH5α, BL21, TOP10, and JM109) within 15 minutes using 500 μL of sample and costs $2.50 per test. The sensor displayed an excellent limit of detection (LOD) of 53 CFU, limit of quantification (LOQ) of 270 CFU, and showed cross-reactivity with strains BL21 and JM109 due to shared epitopes. This advantageous diagnostic device is a potential candidate for high-frequency testing at the point of care as well as applicable to various fields where pathogen detection is of interest.


Sign in / Sign up

Export Citation Format

Share Document