A new method for determination of microsomal haem oxygenase (EC 1.14.99.3) based on quantitation of carbon monoxide formation

Author(s):  
E. Cavallin-Ståhl ◽  
G. -I. Jönsson ◽  
B. Lundh
1974 ◽  
Vol 20 (2) ◽  
pp. 278-281 ◽  
Author(s):  
Alfred Ramieri ◽  
Peter Jatlow ◽  
David Seligson

Abstract We have developed a simple method for rapid determination of carboxyhemoglobin concentration in blood, by use of double-wavelength spectrophotometry. The absorbance of both oxyhemoglobin and reduced hemoglobin are instrumentally nulled out in this procedure, so that the absorption signal reflects HbCO and only a single spectrophotometric reading is required. This procedure is accurate in the range encountered in ambulatory persons as well as in the "toxic" range. Results correlated well with the dithionite reduction procedure. The stability of carboxyhemoglobin in solution was investigated and concentrations of carbon monoxide in groups of smokers and nonsmokers were determined.


2020 ◽  
Vol 14 (4) ◽  
pp. 545-552
Author(s):  
Yevgen Panov ◽  
◽  
Nikolai Gomelia ◽  
Olena Ivanenko ◽  
Andrii Vahin ◽  
...  

In this paper, the influence of carbon material type, temperature and oxygen concentration in gas mixture on the processes of carbon monoxide formation in production of the electrodes by graphitization was explored experimentally. Specific quantity of gas formed for a definite time, reduced to mass unit of carbon loading using pitch, packing materials and charge mixture of industrial use, was calculated. It is demonstrated that pitch provides the highest rate of carbon oxidation with the release of CO and substantially exceeds packing materials and charge mixture for this index.


1960 ◽  
Vol 23 ◽  
pp. 227-232 ◽  
Author(s):  
P WEST ◽  
G LYLES
Keyword(s):  

1977 ◽  
Vol 37 (02) ◽  
pp. 210-215 ◽  
Author(s):  
R Margalit ◽  
E Gidron ◽  
Y Shalitin

SummaryThe term “effective activator” of plasminogen is proposed, to denote the resultant of activator-antiactivator interaction, and a method for the determination of the level of these activators is described. By adding axcess plasminogen to the euglobulin fraction of plasma the influence of the level of endogenous plasminogen and of the antiplasmin is eliminated. It is shown that the level of fibrinogen has very little bearing on the results. An effective activator unit is defined as equal to 1 CTA unit of urokinase activity on a fibrinogen-plasminogen substrate.


1964 ◽  
Vol 12 (01) ◽  
pp. 119-125 ◽  
Author(s):  
Y Shamash ◽  
A Rimon

SummaryA new method for the assay of plasmin inhibitors in human plasma is described. The method consists of determination of the caseinolytic activity of a standard plasmin solution before and after incubation with the inhibitor, with lysine added to the mixture as a stabilizer of plasmin. Using this method, it was found that plasma contains enough inhibitors to inactivate 30 caseinolytic units of plasmin, or 10 times the normal amount of plasminogen in human plasma.


1969 ◽  
Vol 62 (1_Suppl) ◽  
pp. S95-S112 ◽  
Author(s):  
A. H. W. M. Schuurs

ABSTRACT Various techniques for sensitising erythrocytes and latex particles with gonadotrophins, particularly with HCG, are described. The haemagglutination inhibition reactions are generally interpreted by means of »erythrocyte settling patterns«. By a new method of evaluating these patterns a relatively precise quantitative determination is possible. Latex agglutination inhibition reactions on slides are particularly suitable as rapid qualitative tests. In cases where the maximum attainable sensitivity of the agglutination inhibition tests is insufficient, e. g. for determining LH concentrations in urine, the hormone in the test fluid has to be concentrated or extracted. An alternative method is a modified haemagglutination inhibition test for large volumes which is applicable to unconcentrated urine. Due to non-specific inhibitions the above-mentioned tests cannot be applied to unprocessed serum. Agglutination inhibition tests with HCG are already well advanced, pregnancy diagnosis being their main application. Now that highly purified HCG is available, a satisfactory specificity for these tests can be attained. If the immune system for HCG is used for estimating LH, it has to meet additional specificity requirements. Furthermore, the measure of cross-reaction and the choice of standard merit special attention. Finally, a literature survey is given of test systems in which LH and FSH were used as antigens.


Sign in / Sign up

Export Citation Format

Share Document