scholarly journals A Study of Malposition of Central Venous Catheter – A Comparative Study between Ultrasound Guided and Anatomical Landmark Technique

2018 ◽  
Vol 2 (3) ◽  
pp. 277-281
Author(s):  
Lalit Kumar Rajbanshi ◽  
Sambhu Bahadur Karki ◽  
Batsalya Arjyal

Introduction: Central venous catheterization is a routine procedure for long-term infusion therapy and central venous pressure measurement. Sometimes, the catheter tip may be unintentionally placed at the position other than the junction of superior vena cava and right atrium. This is called malposition and can lead to erroneous pressure measurement, increase risk of thrombosis, venous obstruction or other life threatening complications like pneumothorax, cardiac temponade.Objectives: This study aimed to observe the incidence of the malposition and compare the same between ultrasound guided catheterization and blind anatomical landmark technique.Methodology: This study was a prospective comparative study conducted at the intensive care unit of Birat Medical College and Teaching Hospital for two-year duration. All the catheterizations were done either with the use of real time ultrasound or blind anatomical landmark technique. The total numbers of central venous catheterization, the total incidences of malposition were observed. Finally the incidences were compared between real time ultrasound guided technique and blind anatomical landmark technique.Results: In two-year duration of the study, a total of 422 central venous cannulations were successfully done. The real time ultrasound was used for 280 cannulations while blind anatomical landmark technique was used for 162 patients. The study observed various malposition in 36 cases (8.5%). The most common malposition was observed for subclavian vein to ipsilateral internal jugular vein (33.3%) followed by subclavian to subclavian vein (27.8%) and internal jugular to ipsilateral subclavian vein (16.7%). In four patients the catheter had a reverse course in the internal jugular vein while the tip was placed in pleural cavity in three cannulations. There was coiling of the catheter inside left subclavian vein in one patient. The malposition was significantly reduced with the use of the real time ultrasound (P< 0.001). However there is no significant difference in the incidence of the various malposition between ultrasound guidance technique and blind anatomical landmark technique when compared individually.Conclusion: The malposition of the central venous catheter tip was common complication with the overall incidence of 8.5%. The most common malposition was subclavian vein to internal jugular vein. The use of real time ultrasound during the catheterization procedure can significantly reduced the risk of malposition.Birat Journal of Health SciencesVol.2/No.3/Issue 4/Sep- Dec 2017, Page: 277-281

2016 ◽  
Vol 3 (1) ◽  
pp. 18-21 ◽  
Author(s):  
Santosh Sharma Parajuli ◽  
Jeju Nath Pokharel

Background: Catheterization of internal jugular vein can be achieved by either anatomical landmark technique or the ultrasound guided technique. The objective of our study is to find out if ultrasound guided technique could be beneficial in placing central venous catheters by improving the success rate by reducing the number of attempts, decreasing the access time and decreasing the complications rate in comparison to the landmark technique.Methods: Fifty patients scheduled for cardiac surgery requiring central venous cannulation of the right internal jugular vein were divided into two groups: ultrasound guided group ‘U’ and the landmark group ‘L’, each consisting of 25 patients with age more than 15 years. The outcomes were compared in terms of success rate, time taken for successful cannulation and rate of complications.Results: The two groups were comparable in terms of age, weight, heart rate and blood pressure. The mean number of attempts for successful cannulation was 1.08±0.277 and 1.40±0.764 (p=0.055), the time taken in seconds for successful cannulation was 108.56±27.822 and 132.08±72.529 (p=0.137) and the overall complication rate was 0% (0 out of 25) and 32% (8 out of 25) (p=0.02) in the ultrasound guided and the landmark technique group respectively.Conclusion: Ultrasound guided central venous catheterization of internal jugular vein is comparable to the landmark technique in terms of number of attempts and the time required for successful cannulation. Ultrasound guided technique is much safer than the landmark technique to reduce the overall complications rate during central venous cannulation.


2001 ◽  
Vol 95 (6) ◽  
pp. 1377-1379 ◽  
Author(s):  
Sushil P. Ambesh ◽  
Jyotish C. Pandey ◽  
Prakash K. Dubey

Background During subclavian vein catheterization, the most common misplacement of the catheter is cephalad, into the ipsilateral internal jugular vein (IJV). This can be detected by chest radiography. However, after any repositioning of the catheter, subsequent chest radiography is required. In an effort to simplify the detection of a misplaced subclavian vein catheter, the authors assessed a previously published detection method. Methods One hundred adult patients scheduled for subclavian vein cannulation were included in this study. After placement of subclavian vein catheter, chest radiography was performed. While the x-ray film was being processed, the authors performed an IJV occlusion test by applying external pressure on the IJV for approximately 10 s in the supraclavicular area and observed the change in central venous pressure and its waveform pattern. The observations thus obtained were compared with the position of catheter in chest radiographs, and the sensitivity and specificity of this method were evaluated using a 2 x 2 table. Results In 96 patients, subclavian vein cannulation was successfully performed. In four patients, cannulation was unsuccessful; therefore, these patients were excluded from the study. There were six misplacements of venous catheters as detected by radiography. In five (5.2%) patients, the catheter tip was located in the ipsilateral IJV, and in one (1.02%), the catheter tip was located in the contralateral subclavian vein. In the patients who had a misplaced catheter into the IJV, IJV occlusion test results were positive, with an increase of 3-5 mmHg in central venous pressure, whereas the test results were negative in patients who had normally placed catheters or misplacement of a catheter other than in the IJV. There were no false-positive or false-negative test results. Conclusion The IJV occlusion test successfully detects the misplacement of subclavian vein catheter into the IJV. However, it does not detect any other misplacement. The test may allow avoidance of repeated exposure to x-rays after catheter insertion and repositioning.


2016 ◽  
Vol 6 (3) ◽  
Author(s):  
Mehdi Fathi ◽  
Azra Izanloo ◽  
Saeed Jahanbakhsh ◽  
Mehryar Taghavi Gilani ◽  
Ali Majidzadeh ◽  
...  

2017 ◽  
Vol 2017 ◽  
pp. 1-3 ◽  
Author(s):  
Onur Balaban ◽  
Tayfun Aydın

Central venous cannulation of infants may be challenging. Ultrasonography is recommended and has been found superior to classic landmark technique in pediatric central venous cannulation. The cannulation of the subclavian vein using supraclavicular approach under real-time ultrasound guidance is a novel technique. It may have advantages over ultrasound-guided jugular vein cannulation in specific patients. We report a case of 3200-gram 20-day-old anencephalic neonate who had a diffuse generalized edema. The neonate was cannulated successfully via subclavian vein using supraclavicular approach under ultrasound guidance.