catheter malposition
Recently Published Documents


TOTAL DOCUMENTS

94
(FIVE YEARS 19)

H-INDEX

10
(FIVE YEARS 1)

2021 ◽  
pp. 112972982110501
Author(s):  
Gabriel Stefan ◽  
Simona Stancu ◽  
Adrian Zugravu ◽  
Laura Predescu ◽  
Simona Cinca ◽  
...  

Budd-Chiari syndrome due to the tip of an internal jugular tunneled dialysis catheter malposition in inferior vena cava or hepatic vein is a rare complication. We aimed to present our experience and compare it with the previous reports to highlight the clinical features and the optimal management. A 57-year-old female with history of ANCAp vasculitis, treated by hemodialysis in the last 2 years on a right internal jugular vein tunneled catheter was admitted for pain in the right upper quadrant. A subacute Budd-Chiari syndrome due to catheter malposition was diagnosed. The catheter was removed, and a new tunneled hemodialysis line was inserted in the right internal jugular vein with the tip at the junction of right atrium with superior vena cava. Anticoagulation with apixaban 2.5 mg twice daily was started after catheter replacement and the patient was discharged. At 1 month follow-up the patient had no symptoms, and the ultrasound revealed the absence of the thrombus in the inferior vena cava. Imagining monitoring for malposition after insertion or in a clinical context suggestive for Budd-Chiari syndrome is essential for early diagnosis and treatment. In our case, anticoagulation with apixaban and prompt catheter replacement resulted in Budd-Chiari syndrome resolution.


2021 ◽  
pp. 112972982110522
Author(s):  
Octavio J Salgado ◽  
Tushar J Vachharajani

The placement of large bore double-lumen catheters for hemodialysis (HD) is one of the most frequent procedures performed in HD patients. However, these procedures are associated with complications, the most common being catheter malposition. In this context, catheter deviation to the left superior intercostal vein (LISV) is a very uncommon malposition, which must be differentiated from intrathoracic extravascular catheter lodgment. We report a case of an adult male patient on hemodialysis who presented with a thrombosed arteriovenous fistula and requiring urgent HD. His past medical history included hemophilia, allergy to contrast media, and multiple previous central vein catheterizations. A non-tunneled HD catheter was placed without any difficulty in the left internal jugular vein. However, the arterial lumen failed to pull any blood with free flow in the venous lumen. A chest X-ray revealed a surprising finding. The malpositioned catheter was removed successfully without any complications.


Ultrasound ◽  
2021 ◽  
pp. 1742271X2110517
Author(s):  
Mohd Jazman Che Rahim ◽  
Shaik Farid Abdull Wahab ◽  
Mohd Hashairi Fauzi ◽  
Chandran Nadarajan ◽  
Siti Azrin Ab Hamid

Background Contrast-enhanced ultrasonography (CEUS) using saline was studied to detect supradiaphragmatic central venous catheter malposition. Commonly used echocardiographic views are apical 4-chamber (A4c) and subcostal views. However, this standard method is not feasible in certain situations. We explored the feasibility of the right ventricle inflow parasternal long axis (RVI-PLAX) echocardiographic view and dextrose 50% (D50%) contrast solution for detecting supradiaphragmatic central venous catheter malposition. Method This pilot study screened 60 patients who underwent ultrasound-guided supradiaphragmatic central venous catheter insertion. We compared the investigators' guidewire's J-tip detection, D50% rapid atrial swirl sign (RASS) findings on the RVI-PLAX view and the central venous catheter tip on chest radiograph. We also compared the mean capillary blood sugar level before and after the 5 ml D50% flush. Results No guidewire J-tips were detected from the RVI-PLAX view. The first and second investigators’ diagnosis of central venous catheter malposition detected on RVI-PLAX CEUS achieved an almost perfect agreement (κ = 1.0 (95% confidence interval (CI): 0.90 to 1.0), p < .0001). The RVI-PLAX CEUS was not able to detect two central venous catheter malpositions (one atrial malposition and one left brachiocephalic vein venous catheter malposition). The capillary blood sugar was significantly elevated (8.96 mmol/L vs. 9.75 mmol/L) after D50% flush ( p < 0.005) with no complications reported within 30 minutes after the D50% flush. Conclusion RVI-PLAX view should not be used for guidewire detection. CEUS using D50% and RVI-PLAX view are potentially useful tools in detecting central venous catheter malposition. Further studies comparing them with conventional methods are needed.


2021 ◽  
Vol 14 (6) ◽  
pp. e244198
Author(s):  
Hannah Victoria Reynolds ◽  
Peter Stanley Kruger

Author(s):  
Afonso Santos ◽  
Ana Gaspar ◽  
Anna Lima ◽  
Catarina Brás ◽  
Pedro Campos ◽  
...  

Abstract Hemodialysis central venous catheter (CVC) insertion can be complicated in patients with anomalous vessel anatomy. In such cases detailed knowledge of thoracic vessel anatomy is necessary to identify the exact location of the catheter. Central venous placement under ultrasound control has significantly reduced the complications associated with blind puncture and allows an appropriate puncture of the desired vessel, but the CVC can still get misplaced if it follows an anomalous route. Herein, we report a case of dialysis catheter placed into a left sided superior vena cava, only diagnosed after CT scan study.


Author(s):  
Sasivimon Soonsawad ◽  
Emily A. Kieran ◽  
Joseph Y. Ting ◽  
Esther AlonsoPrieto ◽  
Julia K. Panczuk

Objective Umbilical venous catheters (UVC) are widely used in neonatal intensive care (NICU). Noncentral catheter position is known to be associated with multiple adverse complications; however, risk factors for catheter malposition are unclear. This work aimed to identify clinical risk factors and complications associated with UVC malposition in neonates admitted in an NICU. Study Design A retrospective chart review was performed of inborn babies admitted to BC Women's Hospital NICU with UVC inserted in their first 7 days between July 2016 and June 2018. Infant and maternal demographic, radiograph, UVC-related data, and complications were reviewed. Results A total of 257 infants had UVC placed; 158 (61%) and 99 (39%) were in central and noncentral positions after initial placement, respectively. Of initially central-placed UVCs, a further 35 (22%) were pulled back or migrated to malposition on follow-up X-ray. Multivariable logistic regression analysis revealed the use of larger UV (5 Fr) catheter (odds ratio [OR]: 2.5, 95% confidence interval [CI]: 1.1–5.6, p = 0.026) and escalation of respiratory support mode (OR: 1.7, 95% CI: 1.0–2.8, p = 0.049) as significant predictors of catheter malposition. Conclusion Noncentral UVC position as well as migration were common after initial placement in this cohort. The use of larger size UV catheters and increasingly invasive respiratory support were risk factors associated with higher incidence of UVC malposition. Ongoing surveillance of UVC position is thus recommended. Key Points


2021 ◽  
pp. 112972982110025
Author(s):  
Patrick F Frias ◽  
Chloe G Cross ◽  
Claire S Kaufman ◽  
Keith B Quencer

We present a case of a port malposition into the azygos vein resulting in both a broncho-esophageal and veno-bronchial fistula. While complications of central venous catheter malposition into the azygos vein are well documented in literature, these unique complications have not yet been described. This case underscores how utilizing state of the art technology like intra-cavity electrocardiography rather that reliance on fluoroscopy can help eliminate catheter malposition and its potential catastrophic consequences.


2021 ◽  
Vol 2021 ◽  
pp. 1-4
Author(s):  
Ravi Murthy ◽  
Varun Rachakonda ◽  
Juri Bassuner

The development of inoperable biliary obstruction in patients with liver, biliary, and pancreatic neoplasia is commonplace particularly in the advanced stages of these diseases. Under these circumstances, restoring bile flow to the gut is paramount in reestablishing homeostasis. Hitherto, this has been achieved by utilizing passive, gravity-dependent bilioenteric conduits with the use of perforated plastic catheters or metallic stents inserted either in a percutaneous transhepatic fashion or via endoscopic techniques. A frequent untoward event of biliary decompression utilizing percutaneous transhepatic catheters (PTC) is the development of pain, cholangitis, hyperbilirubinemia, or pericatheter bile leak due to the suboptimal normalization of bile flow. In some instances, the etiology of PTC malfunction can be correctly ascribed to catheter malposition and/or catheter lumen obstruction; however, in the majority, it remains radiographically occult on transcatheter cholangiography—the “gold standard.” Regardless of findings, the management remains fluoroscopic repositioning or exchanges for larger diameter catheters to attempt to seal the pericatheter potential space and prevent bile seepage. Unfortunately, these maneuvers are met with limited and unpredictable levels of success. We present the successful management of an instance of recalcitrant external pericatheter bile leak mitigated by employing a hybrid closed loop biliary catheter-pump system by employing an assortment of FDA approved off-the-shelf medical devices.