Minimally Invasive Locking Plate Fixation vs Reamed Intramedullary Nail Fixation on Patients With Open Tibia Fracture

Author(s):  
2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Fu Wang ◽  
Yan Wang ◽  
Jinye Dong ◽  
Yu He ◽  
Lianxin Li ◽  
...  

Abstract Background and hypothesis The typical anterolateral approach is widely used to treat proximal humerus fractures with lateral locking fixation. However, lateral fixation cannot completely avoid medial reduction loss and varus deformity especially in the cases of an unstable medial column. We present a novel medial surgical approach and technique together with a minimally invasive lateral locking plate to fix proximal humerus fractures with an unstable medial column. Materials and methods We performed an anatomical study and reported 8 cases of proximal humerus fractures with unstable medial columns treated with plate fixation through a minimally invasive anterolateral approach and medial approach. All surgeries were performed by the same single surgeon. Patients were followed clinically and radiographically at 1, 3, 6, and 12 months postoperatively. Results There was a safe region located at the medial part of the proximal humerus just beneath the articular surface. An anatomical medial locking proximal humerus plate could be placed in the medial column and did not affect the axillary nerve, blood supply of the humeral head, or stability of the shoulder joint. Successful fracture healing was achieved in all 8 cases. The function and range of motion of the shoulder joint were satisfactory 24 months postoperatively, with an average Constant score (CS) of 82.8. No reduction loss (≥ 10° in any direction), screw cutout, nonunion, or deep infection occurred. Conclusions The combined application of medial anatomical locking plate fixation and minimally invasive lateral locking plate fixation is effective in maintaining operative reduction and preventing varus collapse and implant failure in proximal humerus fractures with an unstable medial column.


2009 ◽  
Vol 58 (4) ◽  
pp. 604-608 ◽  
Author(s):  
Katsuhiko Ishibashi ◽  
Gentaro Hanaishi ◽  
Kenichiro Nakai ◽  
Masato Nagashima ◽  
Hiroaki Tanaka

2017 ◽  
Vol 5 (5) ◽  
pp. 630-634
Author(s):  
Ilir Hasani ◽  
Igor Kaftandziev ◽  
Slavco Stojmenski ◽  
Simon Trpeski ◽  
Hristijan Kostov ◽  
...  

INTRODUCTION: In the past distal tibia fractures, including intraarticular fractures, frequently led to poor functional outcomes. The Ruedi-Allgower four steps open method, and later the Patterson and Sirkin recommendations for delayed operative treatment has made a drastic advancement in the treatment of these fractures. The two-stage minimally-invasive protocol using locking plate fixation proved a historical turning point, improving functional results to the highest levels compared to all other methods.AIM: To present the superior results of the two-stage minimally-invasive method using locking plate fixation, making this a historic step forward in treating distal tibia fractures.MATERIAL AND METHODS: A prospective longitudinal study, collecting data from Traumatology-Clinic in the 2014-2016 periods, available for nine-month follow-up. Twenty-three patients were finally included in the study.RESULTS: In analysing the data collected, we focused our attention on the final functional outcomes as indicated by dorsiflexion nine months after injury and also according to the AOFAS Ankle-Hindfoot Scale. Results were excellent with no or minimal consequences. Where complications were present, these were benign and did not require further surgery.CONCLUSION: We believe this modern method for the treatment of distal tibia fractures should be applied routinely and considered as the gold standard in this domain.


2020 ◽  
Author(s):  
Fu Wang ◽  
Yan Wang ◽  
Jinye Dong ◽  
Yu He ◽  
Lianxin Li ◽  
...  

Abstract Background and hypothesis: The typical anterolateral approach is widely used to treat proximal humerus fractures with lateral locking fixation. However, lateral fixation cannot completely avoid medial reduction loss and varus deformity especially in the cases of an unstable medial column. We present a novel medial surgical approach and technique together with a minimally invasive lateral locking plate to fix proximal humerus fractures with an unstable medial column.Materials and Methods: An anatomical study was performed and an anatomical medial locking proximal humerus plate was designed based on the measurement results. Between November 2014 and April 2017, eight cases of proximal humerus fractures with unstable medial columns underwent medial fixation. All surgeries were performed by a single surgeon. Patients were followed clinically and radiographically at 1, 3, 6 and 12 months postoperatively.Results: There was a safe region located at the medial part of the proximal humerus just beneath the articular surface. An anatomical medial locking proximal humerus plate could be placed in the medial column and did not affect the axillary nerve, blood supply of the humeral head or stability of the shoulder joint. Successful fracture healing was achieved in all 8 cases. The function and range of motion of the shoulder joint were satisfactory 24 months postoperatively, with an average Constant score (CS) of 82.8. No reduction loss (≥ 10 degrees in any direction), screw cutout, nonunion, or deep infection occurred.Conclusions: The combined application of medial anatomical locking plate fixation and minimally invasive lateral locking plate fixation is effective in maintaining operative reduction and preventing varus collapse and implant failure in proximal humerus fractures with an unstable medial column.Level of evidence: Retrospective Study


JAMA ◽  
2017 ◽  
Vol 318 (18) ◽  
pp. 1767 ◽  
Author(s):  
Matthew L. Costa ◽  
Juul Achten ◽  
James Griffin ◽  
Stavros Petrou ◽  
Ian Pallister ◽  
...  

2011 ◽  
Vol 71 (6) ◽  
pp. 1737-1744 ◽  
Author(s):  
Steffen Ruchholtz ◽  
Carsten Hauk ◽  
Ulrike Lewan ◽  
Daniel Franz ◽  
Christian Kühne ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document