Heat Insulation Material on the Basis of Expanded Perlite and Expanded Mineral Binder

2019 ◽  
Vol 767 (1-2) ◽  
pp. 107-112
Author(s):  
◽  
I.N. TIKHOMIROVA ◽  
2015 ◽  
Vol 72 ◽  
pp. 209-215 ◽  
Author(s):  
Indra Muizniece ◽  
Dagnija Blumberga ◽  
Ance Ansone

Author(s):  
Martins Andzs ◽  
Voldemars Skrupskis

Obtaining of a new ecological heat insulation material from always renewable raw material in nature, wood and hemp, derived from wood and hemp fibre remains left from the production process. The study was carried out to find hemp wood parts (shives), fiber, and material first possible compositions together with wood fibres, to produce heat insulation materials. The use of the heat insulation material would be meant for dwelling and recreation houses. In the present research the main characteristics of these materials are determined: moisture content, density, water absorption, as well as the coefficient of heat transmission.


2012 ◽  
Vol 535-537 ◽  
pp. 1609-1614 ◽  
Author(s):  
Hui Min Liu

To prevent a long nozzle (LN) of non-preheating from rupture caused by thermal shock, heat insulation material (HIM) with a lower coefficient of thermal conductivity (CTC) was compounded in the inner hole (inner layer) or around the outer wall (outer layer), and the thermal stress was investigated. The two-dimension axially symmetric model of LN was proposed by simplifying the structure and boundary conditions. The influences of the HIM to the thermal stress of LN were analyzed by finite element method. The results show that the thermal stress suffered by LN can be drastically reduced by the inner layer, making the slow variation, but when its thickness increases from 2 mm to 3 mm, it almost has no influence on the thermal stress. The maximum thermal stress at the neck of LN reduces with the depression of the CTC at the inner layer thickness of 2 mm. The maximum thermal stress of LN can’t be reduced by outer layer, but the lasting time of higher stress can be shortened, and the thermal stress at the later period of steel-irrigating can be lowed. When the outer layer thickness is more than 2 mm, the increase of it has little influence on the thermal stress of LN, and the change of its CTC has little influence on the thermal stress either. The LN with tri-layer has lower thermal stress during all the period of steel-irrigating.


2012 ◽  
Vol 174-177 ◽  
pp. 988-992
Author(s):  
Shuang Mei Cao

This thesis analyzes the current situation of the heat insulation system of composite wall in China. Through comparison, it points out that heat insulation system is the trend of the development for heat preservation and energy saving, and meanwhile, it gives direction for further research to several different new type heat insulation systems.


2012 ◽  
Vol 535-537 ◽  
pp. 1864-1867
Author(s):  
Shao Yan ◽  
Ling Zeng ◽  
Hui Zuo ◽  
Jia Hua Li

This article introduces the method of the building enclosure construction of energy saving residential buildings based on the FHP-Vc inorganic composite silicate heat-insulating board and its practical effect in projects.


Sign in / Sign up

Export Citation Format

Share Document