scholarly journals Robotic and robot-assisted skull base neurosurgery: systematic review of current applications and future directions

2022 ◽  
Vol 52 (1) ◽  
pp. E15

OBJECTIVE The utility of robotic instrumentation is expanding in neurosurgery. Despite this, successful examples of robotic implementation for endoscopic endonasal or skull base neurosurgery remain limited. Therefore, the authors performed a systematic review of the literature to identify all articles that used robotic systems to access the sella or anterior, middle, or posterior cranial fossae. METHODS A systematic review of MEDLINE and PubMed in accordance with PRISMA guidelines performed for articles published between January 1, 1990, and August 1, 2021, was conducted to identify all robotic systems (autonomous, semiautonomous, or surgeon-controlled) used for skull base neurosurgical procedures. Cadaveric and human clinical studies were included. Studies with exclusively otorhinolaryngological applications or using robotic microscopes were excluded. RESULTS A total of 561 studies were identified from the initial search, of which 22 were included following full-text review. Transoral robotic surgery (TORS) using the da Vinci Surgical System was the most widely reported system (4 studies) utilized for skull base and pituitary fossa procedures; additionally, it has been reported for resection of sellar masses in 4 patients. Seven cadaveric studies used the da Vinci Surgical System to access the skull base using alternative, non–TORS approaches (e.g., transnasal, transmaxillary, and supraorbital). Five cadaveric studies investigated alternative systems to access the skull base. Six studies investigated the use of robotic endoscope holders. Advantages to robotic applications in skull base neurosurgery included improved lighting and 3D visualization, replication of more traditional gesture-based movements, and the ability for dexterous movements ordinarily constrained by small operative corridors. Limitations included the size and angulation capacity of the robot, lack of drilling components preventing fully robotic procedures, and cost. Robotic endoscope holders may have been particularly advantageous when the use of a surgical assistant or second surgeon was limited. CONCLUSIONS Robotic skull base neurosurgery has been growing in popularity and feasibility, but significant limitations remain. While robotic systems seem to have allowed for greater maneuverability and 3D visualization, their size and lack of neurosurgery-specific tools have continued to prevent widespread adoption into current practice. The next generation of robotic technologies should prioritize overcoming these limitations.

Neurosurgery ◽  
2013 ◽  
Vol 72 (suppl_1) ◽  
pp. A33-A38 ◽  
Author(s):  
Wei-Chen Hong ◽  
Jui-Chang Tsai ◽  
Steven D. Chang ◽  
Jonathan M. Sorger

Abstract BACKGROUND: The supraorbital keyhole approach has been used in anterior skull base tumor and aneurysm surgery. However, there are debates regarding the safety and limitations of this kind of approach. OBJECTIVE: To determine the feasibility and potential benefits of surgical robotic technology in minimally invasive neurosurgery. METHODS: Two fresh cadaver heads were studied with the da Vinci Surgical System with 0° and 30° stereoscopic endoscopes to visualize neuroanatomy. The ability of the system to suture and place clips under the keyhole approach was tested. RESULTS: The da Vinci Surgical System was used throughout the supraorbital transeyebrow keyhole approach. With the use of standard microdissection techniques, the optic nerve, optic chiasm, carotid artery, and third cranial nerve were visualized. The sylvian fissure was then exposed from the proximal sylvian membrane to the distal M1 segment. With the EndoWrist microforceps, suturing can be achieved smoothly to close a defect created on the M2 artery. Although the benefits in adjusting clips during aneurysm surgery could be provided by an articulating applier, a proper robotic applier is not currently available. CONCLUSION: The minimally invasive supraorbital keyhole surgery can be achieved with the da Vinci Surgical System in cadaver models. This system provides neurosurgeons with broader vision and articulable instruments, which standard microsurgical systems do not provide. Further studies are necessary to evaluate the safety and benefits of using the da Vinci Surgical System in minimally invasive neurosurgery.


2020 ◽  
Vol 36 (S1) ◽  
pp. 36-36
Author(s):  
Jin Zhao ◽  
Min Zhong ◽  
Min Hu

IntroductionA robotically assisted surgical system, the da Vinci surgical system (DVSS), is a sophisticated surgical platform equipped with immersive 3D visualization and dexterous articulating endoscopic instruments. Surgeons can intuitively control the surgical system to perform delicate surgical tasks. Robotic surgery has gained popularity globally ever since its birth and was approved to market by the China Food and Drug Administration in 2006. This study aims to map the current use of DVSSs in mainland China and the trends from 2009 to 2019.MethodsA full-sample survey of all hospitals equipped with DVSSs was conducted in mainland China, collecting data on hospitals and surgical departments using DVSSs, operation volume, and time of installation. Disease classification was standardized to obtain DVSS use in each department. EXCEL software was used for logging and cleaning the data. The analysis focused on descriptive analysis to map trends of DVSS use in China and present geographical and department distribution.ResultsThe DVSSs installed have grown from seven in 2009 to 135 in 2019. By the end of 2019, twenty-eight provinces in China have been equipped with the DVSSs, among which eighty-seven in the eastern regions, twenty-seven in the central regions, and twenty-one in the western regions. The annual volume of operations grew from 339 in 2009 to 38,991 in 2019, at an annual rate of 60.7 percent. The average workload conducted by a single robot is much higher than that of their counterparts in other countries. The largest share of the volume is in department of urology (48%), followed by general surgery (25%) and thoracic surgery (13%).ConclusionsThe use of DVSSs in China has been growing rapidly and extensively, with certain differences between geographical regions and surgical departments. We need to further explore the factors affecting its use and operation efficiency and to evaluate the effectiveness as well as cost-effectiveness in real-world clinical practice to inform public policies on application of DVSS, for example, license and insurance.


Author(s):  
Braden Millan ◽  
Shavy Nagpal ◽  
Maylynn Ding ◽  
Jason Y. Lee ◽  
Anil Kapoor

Objectives Since the introduction of the first master–slave robotic platform for surgical procedures, there have been ongoing modifications and development of new platforms, but there is still a paucity of commercially available systems. Our study aims to identify all master–slave robotic surgical platforms currently commercially available or in development around the world with applications in urologic surgery. Methods A scoping literature search was performed using PRISMA methodology to identify all relevant publications in English in PubMed, PubMed Central, and Embase, with additional information being obtained from official company websites. Results Ten robotic platforms with either proven or potential application in urologic surgery were identified: the da Vinci surgical system (Intuitive), Senhance surgical system (Transentrix), Versius Surgical (CMR Ltd), Enos surgical system (Titan Medical), Revo –I (Meere Company), MiroSurge (DLR), Avatera System (Avatera Medical), Hugo Surgical Robot (Medtronic), Ottava (J&J, Ethicon, Areus), and Hinotori (Medicaroid Corporation). Conclusions This review highlights the distinct features of emerging master–slave robotic platforms with applications in urologic surgery. Research and development are now focused on finding wider applications, improving outcomes, increasing availability, and reducing cost. Additional research is required comparing newly developed master–slave robotic platforms with those already well established.


2011 ◽  
Vol 36 (5) ◽  
pp. 496-498 ◽  
Author(s):  
Norihiko Ishikawa ◽  
Masahiko Kawaguchi ◽  
Hideki Moriyama ◽  
Nobuhiro Tanaka ◽  
Go Watanabe

Sign in / Sign up

Export Citation Format

Share Document