scholarly journals Transcarotid access for remote robotic endovascular neurointerventions: a cadaveric proof-of-concept study

2022 ◽  
Vol 52 (1) ◽  
pp. E18

OBJECTIVE The purpose of this proof-of-concept study was to demonstrate the setup and feasibility of transcarotid access for remote robotic neurointerventions in a cadaveric model. METHODS The interventional procedures were performed in a fresh-frozen cadaveric model using an endovascular robotic system and a robotic angiography imaging system. A prototype remote, robotic-drive system with an ethernet-based network connectivity and audio-video communication system was used to drive the robotic system remotely. After surgical exposure of the common carotid artery in a cadaveric model, an 8-Fr arterial was inserted and anchored. A telescopic guiding sheath and catheter/microcatheter combination was modified to account for the “workable” length with the CorPath GRX robotic system using transcarotid access. RESULTS To simulate a carotid stenting procedure, a 0.014-inch wire was advanced robotically to the extracranial internal carotid artery. After confirming the wire position and anatomy by angiography, a self-expandable rapid exchange nitinol stent was loaded into the robotic cassette, advanced, and then deployed robotically across the carotid bifurcation. To simulate an endovascular stroke recanalization procedure, a 0.014-inch wire was advanced into the proximal middle cerebral artery with robotic assistance. A modified 2.95-Fr delivery microcatheter (Velocity, Penumbra Inc.) was loaded into the robotic cassette and positioned. After robotic retraction of the wire, it was switched manually to a mechanical thrombectomy device (Solitaire X, Medtronic). The stentriever was then advanced robotically into the end of the microcatheter. After robotic unfolding and short microcatheter retraction, the microcatheter was manually removed and the stent retriever was extracted using robotic assistance. During intravascular navigation, the device position was guided by 2D angiography and confirmed by 3D cone-beam CT angiography. CONCLUSIONS In this proof-of-concept cadaver study, the authors demonstrated the setup and technical feasibility of transcarotid access for remote robot-assisted neurointerventions such as carotid artery stenting and mechanical thrombectomy. Using transcarotid access, catheter length modifications were necessary to achieve “working length” compatibility with the current-generation CorPath GRX robotic system. While further improvements in dedicated robotic solutions for neurointerventions and next-generation thrombectomy devices are necessary, the transcarotid approach provides a direct, relatively rapid access route to the brain for delivering remote stroke treatment.

2011 ◽  
Vol 3 (4) ◽  
pp. 390-394 ◽  
Author(s):  
A. M. Spiotta ◽  
T. Sivapatham ◽  
Q. Teng ◽  
S. I. Moskowitz ◽  
F. K. Hui

2018 ◽  
Vol 9 (2) ◽  
pp. 197-203 ◽  
Author(s):  
Ryan A. Rimmer ◽  
Chandala Chitguppi ◽  
Hermes G. Garcia ◽  
Ian J. Koszewski ◽  
Gurston G. Nyquist ◽  
...  

2020 ◽  
Vol 133 (6) ◽  
pp. 1830-1836 ◽  
Author(s):  
Gavin W. Britz ◽  
Sandip S. Panesar ◽  
Peter Falb ◽  
Johnny Tomas ◽  
Virendra Desai ◽  
...  

OBJECTIVEThe aim of this study was to evaluate new, neuroendovascular-specific engineering and software modifications to the CorPath GRX Robotic System for their ability to support safer and more effective cranial neurovascular interventions in a preclinical model.METHODSActive device fixation (ADF) control software, permitting automated manipulation of the guidewire relative to the microcatheter, and a modified drive cassette suitable for neuroendovascular instruments were the respective software and hardware modifications to the current CorPath GRX robot, which was cleared by the FDA for percutaneous coronary and peripheral vascular intervention. The authors then trialed the modified system in a live porcine model with simulated neuroendovascular pathology. Femoral access through the aortic arch to the common carotid artery was accomplished manually (without robotic assistance), and the remaining endovascular procedures were performed with robotic assistance. The system was tested for the enhanced ability to navigate and manipulate neurovascular-specific guidewires and microcatheters. The authors specifically evaluated the movement of the wire forward and backward during the advancement of the microcatheter.RESULTSNavigation of the rete mirabile and an induced aneurysm within the common carotid artery were successful. The active device fixation feature enabled independent advancement and retraction of the guidewire and working device relative to the microcatheter. When ADF was inactive, the mean forward motion of the guidewire was 5 mm and backward motion was 0 mm. When ADF was active, the mean forward motion of the guidewire was 0 mm and backward motion was 1.5 mm. The modifications made to the robotic cassette enabled the system to successfully manipulate the microcatheter and guidewire safely and in a manner more suited to neuroendovascular procedures than before. There were no occurrences of dissection, extravasation, or thrombosis.CONCLUSIONSThe robotic system was originally designed to navigate and manipulate devices for cardiac and peripheral vascular intervention. The current modifications described here improved its utility for the more delicate and tortuous neurovascular environment. This will set the stage for the development of a neurovascular-specific robot.


Sign in / Sign up

Export Citation Format

Share Document