Pedicle screw fixation for isthmic spondylolisthesis: does posterior lumbar interbody fusion improve outcome over posterolateral fusion?

2003 ◽  
Vol 99 (2) ◽  
pp. 143-150 ◽  
Author(s):  
Giovanni La Rosa ◽  
Alfredo Conti ◽  
Fabio Cacciola ◽  
Salvatore Cardali ◽  
Domenico La Torre ◽  
...  

Object. Posterolateral fusion involving instrumentation-assisted segmental fixation represents a valid procedure in the treatment of lumbar instability. In cases of anterior column failure, such as in isthmic spondylolisthesis, supplemental posterior lumbar interbody fusion (PLIF) may improve the fusion rate and endurance of the construct. Posterior lumbar interbody fusion is, however, a more demanding procedure and increases costs and risks of the intervention. The advantages of this technique must, therefore, be weighed against those of a simple posterior lumbar fusion. Methods. Thirty-five consecutive patients underwent pedicle screw fixation for isthmic spondylolisthesis. In 18 patients posterior lumbar fusion was performed, and in 17 patients PLIF was added. Clinical, economic, functional, and radiographic data were assessed to determine differences in clinical and functional results and biomechanical properties. At 2-year follow-up examination, the correction of subluxation, disc height, and foraminal area were maintained in the group in which a PLIF procedure was performed, but not in the posterolateral fusion—only group (p < 0.05). Nevertheless, no statistical intergroup differences were demonstrated in terms of neurological improvement (p = 1), economic (p = 0.43), or functional (p = 0.95) outcome, nor in terms of fusion rate (p = 0.49). Conclusions. The authors' findings support the view that an interbody fusion confers superior mechanical strength to the spinal construct; when posterolateral fusion is the sole intervention, progressive loss of the extreme correction can be expected. Such mechanical insufficiency, however, did not influence clinical outcome.

2002 ◽  
Vol 96 (1) ◽  
pp. 50-55 ◽  
Author(s):  
Christopher E. Wolfla ◽  
Dennis J. Maiman ◽  
Frank J. Coufal ◽  
James R. Wallace

Object. Intertransverse arthrodesis in which instrumentation is placed is associated with an excellent fusion rate; however, treatment of patients with symptomatic nonunion presents a number of difficulties. Revision posterior and traditional anterior procedures are associated with methodological problems. For example, in the latter, manipulation of the major vessels from L-2 to L-4 may be undesirable. The authors describe a method for performing retroperitoneal lumbar interbody fusion (LIF) in which a threaded cage is placed from L-2 through L-5 via a lateral trajectory, and they also detail a novel technique for implanting a cage from L-5 to S-1 via an oblique trajectory. Although they present data obtained over a 2-year period in the study of 15 patients, the focus of this report is primarily on describing the surgical procedure. Methods. The lateral lumbar spine was exposed via a standard retroperitoneal approach. Using the anterior longitudinal ligament as a landmark, the L2–3 through L4–5 levels were fitted with instrumentation via a true lateral trajectory; the L5—S1 level was fitted with instrumentation via an oblique trajectory. A single cage was placed at each instrumented level. Fifteen symptomatic patients in whom previous lumbar fusion had failed underwent retroperitoneal LIF. Thirty-eight levels were fitted with instrumentation. There have been no instrumentation-related failures, and fusion has occurred at 37 levels during the 2-year postoperative period. Conclusions. The use of retroperitoneal LIF in which threaded fusion cages are used avoids the technical difficulties associated with repeated posterior procedures. In addition, it allows L2—S1 instrumentation to be placed anteriorly via a single surgical approach. This construct has been shown to be biomechanically sound in animal models, and it appears to be a useful alternative for the management of failed multilevel intertransverse arthrodesis.


1999 ◽  
Vol 91 (2) ◽  
pp. 186-192 ◽  
Author(s):  
Siviero Agazzi ◽  
Alain Reverdin ◽  
Daniel May

Object. The authors conducted a retrospective study to provide an independent evaluation of posterior lumbar interbody fusion (PLIF) in which impacted carbon cages were used. Interbody cages have been developed to replace tricortical interbody grafts in anterior and PLIF procedures. Superior fusion rates and clinical outcomes have been claimed by the developers. Methods. In a retrospective study, the authors evaluated 71 consecutive patients in whom surgery was performed between 1995 and 1997. The median follow-up period was 28 months. Clinical outcome was assessed using the Prolo scale. Fusion results were interpreted by an independent radiologist. The fusion rate was 90%. Overall, 67% of the patients were satisfied with their outcome and would undergo the same operation again. Based on the results of the Prolo scale, however, in only 39% of the patients were excellent or good results achieved. Forty-six percent of the work-eligible patients resumed their working activity. Clinical outcome and return-to-work status were significantly associated with socioeconomic factors such as preoperative employment (p = 0.03), compensation issues (p = 0.001), and length of preoperative sick leave (p = 0.01). Radiographically demonstrated fusion was not statistically related to clinical outcome (p = 0.2). Conclusions. This is one of the largest independent series in which PLIF with cages has been evaluated. The results show that the procedure is safe and effective with a 90% fusion rate and a 66% overall satisfaction rate, which compare favorably with those of traditional fixation techniques but fail to match the higher results claimed by the innovators of the cage techniques. The authors' experience confirms the reports of others that many patients continue to experience incapacitating back pain despite successful fusion and neurological recovery.


2001 ◽  
Vol 95 (2) ◽  
pp. 190-195 ◽  
Author(s):  
Bhupal Chitnavis ◽  
Giuseppe Barbagallo ◽  
Richard Selway ◽  
Ronan Dardis ◽  
Ahmed Hussain ◽  
...  

Object. The authors undertook a study to assess the value of posterior lumbar interbody fusion (PLIF) in which carbon fiber cages (CFCs) were placed in patients undergoing revision disc surgery for symptoms suggesting neural compression with low-back pain. Methods. The authors followed their first 50 patients for a maximum of 5 years and a minimum of 6 months after implantation of the CFCs. Patients in whom magnetic resonance (MR) imaging demonstrated “simple” recurrent herniation did not undergo PLIF. Surgery was performed in patients with symptoms of neural root compression, tension signs, and back pain with focal disc degeneration and nerve root distortion depicted on MR imaging compatible with clinical signs and symptoms. In 40 patients (80%) pedicle screws were not used. Clinical outcome was assessed using the Prolo Functional Economic Outcome Rating scale. Fusion outcome was assessed using an established classification. Symptoms in 46 patients (92%) improved after surgery, and given their outcomes, 45 (90%) would have undergone the same surgery again. Two thirds of patients experienced good or excellent outcomes (Prolo score ≥ 8) at early and late follow up. There was no difference in clinical outcome between those in whom pedicle screws were and were not implanted (p = 0.83, Mann—Whitney U-test). The fusion rate at 2 years postsurgery was 95%. There were minimal complications, and no patients fared worse after surgery. No patient has undergone additional surgical treratment of the fused intervertebral space. Conclusions. In this difficult group of patients the aim remains to improve symptoms but not cure the disease. A high fusion rate is possible when using the CFCs. Clinical success depends on selecting patients in whom radiological and clinical criteria accord. Pedicle screws are not necessary if facet joints are preserved, and high fusion rates and clinical success are possible without them.


2003 ◽  
Vol 99 (2) ◽  
pp. 221-228 ◽  
Author(s):  
Hideki Sudo ◽  
Itaru Oda ◽  
Kuniyoshi Abumi ◽  
Manabu Ito ◽  
Yoshihisa Kotani ◽  
...  

Object. Posterior lumbar interbody fusion (PLIF) was developed to overcome the limitations of posterolateral fusion in correcting spinal deformity and maintaining lumbar lordosis. In this study the authors compare the biomechanical effects of three different posterior reconstructions on the adjacent motion segment. Methods. Ten calf spinal (L2—S1) specimens underwent nondestructive flexion—extension testing (± 6 Nm). The specimens were destabilized at the L5—S1 levels after intact testing. This was followed by pedicle screw fixation with and without interbody cages as follows: 1) with straight rods (“aligned” posterolateral fusion); 2) with kyphotically prebent rods (“kyphotic” posterolateral fusion); and 3) with interbody cages combined with straight rods (“aligned” PLIF/posterolateral fusion). The range of motion (ROM) of the operative segments, the intradiscal pressure (IDP), and longitudinal lamina strain in the superior adjacent segment (L4–5) were analyzed. The ROM associated with aligned PLIF/posterolateral fusion-treated specimens was significantly less than both the aligned and kyphotic posterolateral fusion-treated procedures in both flexion and extension loading (p < 0.05). The aligned PLIF/posterolateral fusion was associated with greater IDP and the lamina strain compared with the aligned and kyphotic posterolateral fusion groups in flexion loading. Under extension loading, greater IDP and lamina strain were present in the kyphotic posterolateral fusion group than in the aligned posterolateral fusion group. The highest IDP and lamina strain were shown in the aligned PLIF/posterolateral fusion group. Conclusions. Compared with kyphotic posterolateral fusion, PLIF may lead to even higher load at the superior adjacent level because of the increased stiffness of the fixed segments even if local kyphosis is corrected by PLIF.


2000 ◽  
Vol 92 (1) ◽  
pp. 87-92 ◽  
Author(s):  
Annette Kettler ◽  
Hans-Joachim Wilke ◽  
Rupert Dietl ◽  
Matthias Krammer ◽  
Christianto Lumenta ◽  
...  

Object. The function of interbody fusion cages is to stabilize spinal segments primarily by distracting them as well as by allowing bone ingrowth and fusion. An important condition for efficient formation of bone tissue is achieving adequate spinal stability. However, the initial stability may be reduced due to repeated movements of the spine during everyday activity. Therefore, in addition to immediate stability, stability after cyclic loading is of remarkable relevance; however, this has not yet been investigated. The object of this study was to investigate the immediate stabilizing effect of three different posterior lumbar interbody fusion cages and to clarify the effect of cyclic loading on the stabilization. Methods. Before and directly after implantation of a Zientek, Stryker, or Ray posterior lumbar interbody fusion cage, 24 lumbar spine segment specimens were each evaluated in a spine tester. Pure lateral bending, flexion—extension, and axial rotation moments (± 7.5 Nm) were applied continuously. The motion in each specimen was measured simultaneously. The specimens were then loaded cyclically (40,000 cycles, 5 Hz) with an axial compression force ranging from 200 to 1000 N. Finally, they were tested once again in the spine tester. Conclusions. In general, a decrease of movement in all loading directions was noted after insertion of the Zientek and Ray cages and an increase of movement after implantation of a Stryker cage. In all three cage groups greater stability was demonstrated in lateral bending and flexion than in extension and axial rotation. Reduced stability during cyclic loading was observed in all three cage groups; however, loss of stability was most pronounced when the Ray cage was used.


2004 ◽  
Vol 1 (3) ◽  
pp. 261-266 ◽  
Author(s):  
Dennis J. Rivet ◽  
David Jeck ◽  
James Brennan ◽  
Adrian Epstein ◽  
Carl Lauryssen

Object. The authors conducted a prospective study to evaluate the clinical and radiological outcomes and complications associated with uni- and bilateral transforaminal lumbar interbody fusion (TLIF) performed using carbon fiber Brantigan I/F Cages and pedicle screw fixation. Methods. Forty-two consecutive patients who had undergone uni- or bilateral TLIF between February 1999 and July 2000 were prospectively evaluated. Clinical outcome was graded using a modified Prolo Scale, the McGill Pain Index Scale, a follow-up questionnaire, and charts. An independent radiologist assessed radiological outcomes. All patients were followed for at least 1 year. Based on Prolo Scale scores, an excellent or good 1-year outcome was achieved in 73% of patients; 90% of patients responded that they would undergo the procedure again. At 1 year, radiographic fusion was demonstrated in 74% and was statistically related to clinical outcome (p < 0.05). There were no deaths or major hardware failures. Complications requiring repeated surgery included one case of cerebrospinal fluid (CSF) leakage and one case in which the hemovac drain was retained. There were four cases involving minor wound infections, eight involving CSF leaks, and none requiring repeated surgery. On routine follow-up radiography one pedicle screw was found to be broken; the patient remained asymptomatic and fusion occurred. Conclusions. Unilateral and bilateral TLIF involving placement of carbon fiber cages and pedicle screw fixation are effective treatment options in patients with indications for lumbar arthrodesis. The procedures result in acceptable rates of fusion and clinical success, and a minimal incidence of morbidity when performed by an experienced surgeon.


Sign in / Sign up

Export Citation Format

Share Document