Parent Artery Straightening after Flow-Diverter Stenting Improves the Odds of Aneurysm Occlusion

Author(s):  
K. Janot ◽  
R. Fahed ◽  
A. Rouchaud ◽  
K. Zuber ◽  
G. Boulouis ◽  
...  
2014 ◽  
Vol 8 (1) ◽  
pp. 81-86 ◽  
Author(s):  
Jonathan Attali ◽  
Azzedine Benaissa ◽  
Sébastien Soize ◽  
Krzysztof Kadziolka ◽  
Christophe Portefaix ◽  
...  

Background and purposeFollow-up of intracranial aneurysms treated by flow diverter with MRI is complicated by imaging artifacts produced by these devices. This study compares the diagnostic accuracy of three-dimensional time-of-flight MR angiography (3D-TOF-MRA) and contrast-enhanced MRA (CE-MRA) at 3 T for the evaluation of aneurysm occlusion and parent artery patency after flow diversion treatment, with digital subtraction angiography (DSA) as the gold standard.Materials and methodsPatients treated with flow diverters between January 2009 and January 2013 followed by MRA at 3 T (3D-TOF-MRA and CE-MRA) and DSA within a 48 h period were included in a prospective single-center study. Aneurysm occlusion was assessed with full and simplified Montreal scales and parent artery patency with three-grade and two-grade scales.ResultsTwenty-two patients harboring 23 treated aneurysms were included. Interobserver agreement using simplified scales for occlusion (Montreal) and parent artery patency were higher for DSA (0.88 and 0.61) and CE-MRA (0.74 and 0.55) than for 3D-TOF-MRA (0.51 and 0.02). Intermodality agreement was higher for CE-MRA (0.88 and 0.32) than for 3D-TOF-MRA (0.59 and 0.11). CE-MRA yielded better accuracy than 3D-TOF-MRA for aneurysm remnant detection (sensitivity 83% vs 50%; specificity 100% vs 100%) and for the status of the parent artery (specificity 63% vs 32%; sensitivity 100% vs 100%).ConclusionsAt 3 T, CE-MRA is superior to 3D-TOF-MRA for the evaluation of aneurysm occlusion and parent artery patency after flow diversion treatment. However, intraluminal evaluation remains difficult with MRA regardless of the sequence used.


2014 ◽  
Vol 8 (1) ◽  
pp. 94-98 ◽  
Author(s):  
Simona Hodis ◽  
Yong-Hong Ding ◽  
Daying Dai ◽  
Ravi Lingineni ◽  
Fernando Mut ◽  
...  

Background and purposeImplanted, actual flow diverter pore density is thought to be strongly influenced by proper matching between the device size and parent artery diameter. The objective of this study was to characterize the correlation between device sizing, metal coverage, and the resultant occlusion of aneurysms following flow diverter treatment in a rabbit model.MethodsRabbit saccular aneurysms were treated with flow diverters (iso-sized to proximal parent artery, 0.5 mm oversized, or 1.0 mm oversized, respectively, n=6 for each group). Eight weeks after implantation, the angiographic degree of aneurysm occlusion was graded (complete, near-complete, or incomplete). The ostium of the explanted aneurysm covered with the flow diverter struts was photographed. Based on gross anatomic findings, the metal coverage and pore density at the ostium of the aneurysm were calculated and correlated with the degree of aneurysm occlusion.ResultsAngiographic results showed there were no statistically significant differences in aneurysm geometry and occlusion among groups. The mean parent artery diameter to flow diverter diameter ratio was higher in the 1.0 mm oversized group than in the other groups. Neither the percentage metal coverage nor the pore density showed statistically significant differences among groups. Aneurysm occlusion was inversely correlated with the ostium diameter, irrespective of the size of the device implanted.ConclusionsDevice sizing alone does not predict resultant pore density or metal coverage following flow diverter implantation in the rabbit aneurysm model. Aneurysm occlusion was not impacted by either metal coverage or pore density, but was inversely correlated with the diameter of the ostium.


2016 ◽  
Vol 22 (2) ◽  
pp. 153-157 ◽  
Author(s):  
Daying Dai ◽  
Yong-Hong Ding ◽  
Michael Kelly ◽  
Ramanathan Kadirvel ◽  
David Kallmes

We report histopathological findings from a human cerebral aneurysm following treatment with a flow diverter. A 75-year-old male underwent flow diversion treatment (Pipeline Embolization Device (PED)) and coil embolization for treatment of an aneurysm at the basilar tip. At four months, angiography showed complete aneurysm occlusion; at 12 months angiography demonstrated that the aneurysm had reopened. The patient expired from brainstem compression. The aneurysm cavity was primarily filled with unorganized thrombus. Thick, interrupted neointima crossed the neck interface indicating blood flow into aneurysm through small channels. Along the parent artery the PED was covered by neointima having a measured thickness of 0.19 ± 0.01 mm; the maximal stenosis of the proximal parent artery was 27%. The perforating arteries that were crossed by the PED remained patent. Findings in this human case are similar to those in the elastase-induced aneurysms in rabbits.


2017 ◽  
Vol 42 (6) ◽  
pp. E3 ◽  
Author(s):  
Francesco Briganti ◽  
Giuseppe Leone ◽  
Luigi Cirillo ◽  
Oreste de Divitiis ◽  
Domenico Solari ◽  
...  

OBJECTIVEFlow diversion has emerged as a viable treatment option for selected intracranial aneurysms and recently has been gaining traction. The aim of this study was to evaluate the safety and effectiveness of flow-diverter devices (FDDs) over a long-term follow-up period.METHODSThe authors retrospectively reviewed all cerebral aneurysm cases that had been admitted to the Division of Neurosurgery of the Università degli Studi di Napoli between November 2008 and November 2015 and treated with an FDD. The records of 60 patients (48 females and 12 males) harboring 69 cerebral aneurysms were analyzed. The study end points were angiographic evidence of complete aneurysm occlusion, recanalization rate, occlusion of the parent artery, and clinical and radiological evidence of brain ischemia. The occlusion rate was evaluated according to the O’Kelly-Marotta (OKM) Scale for flow diversion, based on the degree of filling (A, total filling; B, subtotal filling; C, entry remnant; D, no filling). Postprocedural, midterm, and long-term results were strictly analyzed.RESULTSComplete occlusion (OKM D) was achieved in 63 (91%) of 69 aneurysms, partial occlusion (OKM C) in 4 (6%), occlusion of the parent artery in 2 (3%). Intraprocedural technical complications occurred in 3 patients (5%). Postprocedural complications occurred in 6 patients (10%), without neurological deficits. At the 12-month follow-up, 3 patients (5%) experienced asymptomatic cerebral infarction. No further complications were observed at later follow-up evaluations (> 24 months). There were no reports of any delayed aneurysm rupture, subarachnoid or intraparenchymal hemorrhage, ischemic complications, or procedure- or device-related deaths.CONCLUSIONSEndovascular treatment with an FDD is a safe treatment for unruptured cerebral aneurysms, resulting in a high rate of occlusion. In the present study, the authors observed effective and stable aneurysm occlusion, even at the long-term follow-up. Data in this study also suggest that ischemic complications can occur at a later stage, particularly at 12–18 months. On the other hand, no other ischemic or hemorrhagic complications occurred beyond 24 months.


2014 ◽  
Vol 7 (4) ◽  
pp. e13-e13 ◽  
Author(s):  
Thomas Mattingly ◽  
Brian Van Adel ◽  
Erin Dyer ◽  
Pablo Lopez-Ojeda ◽  
David M Pelz ◽  
...  

2021 ◽  
pp. neurintsurg-2021-017430
Author(s):  
Clemens Hufnagl ◽  
Erasmia Broussalis ◽  
Christophe Cognard ◽  
Jochen Grimm ◽  
Constantin Hecker ◽  
...  

BackgroundUsing a surgical aneurysm model, this study assessed the performance of a new flow diverter (FD), the DiVeRt, and evaluated the angiographic and histologic features at different periods after stent deployment.MethodsFifteen New Zealand White rabbits were treated 3 days prior to intervention and until euthanization with dual antiplatelets. DiVeRt was implanted in bilateral carotid aneurysms (n=30) as well as in the aorta (n=15). The rate of technical success, assessment of aneurysm occlusion (measured by the O'Kelly–Marotta grading (OKM) scale), and stent patency were examined using angiography and histologic examinations in three groups at 1, 3, and 6 months follow-up (FU). In each FU group one control animal was included and treated with the XCalibur stent (n=3).ResultsOverall, DiVeRt placement was successful and without apparent intraprocedural complications. In total, four stents in the carotid artery were occluded and in-stent stenosis was registered in two carotid (7%) and one aortic (6%) vessels. Complete or near complete aneurysm occlusion (OKM scale D1 and C3) was seen in 100% in the 1-month FU group, 70% in the 2-month FU group, and 100% in the 3-month FU group. Histology showed loose, organizing fibrous tissue matrix within the sac and adequate neck endothelialization in all vessels. All branches covered by the DiVeRt remained patent.ConclusionsThe DiVeRt system appears to be feasible and effective for the treatment of aneurysms with high rates of complete aneurysm occlusion, excellent vessel patency, and evidence of high biocompatibility. Occurrences of parent artery occlusion at follow-up did not result in clinical consequences.


2021 ◽  
pp. neurintsurg-2021-017469
Author(s):  
Cameron G McDougall ◽  
Orlando Diaz ◽  
Alan Boulos ◽  
Adnan H Siddiqui ◽  
Justin Caplan ◽  
...  

ObjectiveTo evaluate the safety and effectiveness of the Flow Redirection Endoluminal Device (FRED) flow diverter in support of an application for Food and Drug Administration approval in the USA.Methods145 patients were enrolled in a prospective, single-arm multicenter trial. Patients with aneurysms of unfavorable morphology for traditional endovascular therapies (large, wide-necked, fusiform, etc) were included. The trial was designed to demonstrate non-inferiority in both safety and effectiveness, comparing trial results with performance goals (PGs) established from peer-reviewed published literature. The primary safety endpoint was death or major stroke (National Institutes of Health Stroke Scale score ≥4 points) within 30 days of the procedure, or any major ipsilateral stroke or neurological death within the first year. The primary effectiveness endpoint was complete occlusion of the target aneurysm with ≤50% stenosis of the parent artery at 12 months after treatment, and in which an alternative treatment of the target intracranial aneurysm had not been performed.Results145 patients underwent attempted placement of a FRED device, and one or more devices were placed in all 145 patients. 135/145 (93%) had a single device placed. Core laboratory adjudication deemed 106 (73.1%) of the aneurysms large or giant. A safety endpoint was experienced by 9/145 (6.2%) patients, successfully achieving the safety PG of <15%. The effectiveness PG of >46% aneurysm occlusion was also achieved, with the effectiveness endpoint being met in 80/139 (57.6%)ConclusionAs compared with historically derived performance benchmarks, the FRED flow diverter is both safe and effective for the treatment of appropriately selected intracranial aneurysms.Clinical registration numberNCT01801007


2021 ◽  
pp. 159101992110279
Author(s):  
Muhammad Waqas ◽  
Rimal H Dossani ◽  
Modhi Alkhaldi ◽  
Jocelyn Neveu ◽  
Justin M Cappuzzo ◽  
...  

Introduction The Flow Redirection Endoluminal Device (FRED; MicroVention) is a dual-layered flow diverter used for the treatment of intracranial aneurysms. The objective of this systematic review was to compile device-related safety and effectiveness data. Methods The literature from January 1, 2013 to April 30, 2021 was searched for studies describing use of the FRED for intracranial aneurysm treatment irrespective of aneurysm location and morphology. The review included anterior and posterior circulation ruptured and unruptured saccular, fusiform or dissection, and blister aneurysms. MeSH terms related to “flow re-direction endoluminal device” and “FRED for aneurysms” were used. Data related to indication, complications, and rates of aneurysm occlusion were retrieved and analyzed. Results Twenty-two studies with 1729 intracranial aneurysms were included in this review. Overall reported morbidity was 3.9% (range 0–20%). Overall procedure-related mortality was 1.4% (range 0–6%). Complication rates fell into 5 categories: technical (3.6%), ischemic (3.8%), thrombotic or stenotic (6%), hemorrhagic (1.5%), and non-neurological (0.8%). The aneurysm occlusion rate between 0 and 3 months (reported in 11 studies) was 47.8%. The occlusion rate between 4 and 6 months (reported in 14 studies) was 73.8%. Occlusion rates continued to increase to 75.1% at 7–12 months (reported in 10 studies) and 86.6% for follow-up beyond 1 year (reported in 10 studies). Conclusion This review indicated that the FRED is a safe and effective for the treatment of intracranial aneurysms. Future studies should directly compare the FRED with other flow diverters for a better understanding of comparative safety and effectiveness among the different devices.


Sign in / Sign up

Export Citation Format

Share Document