scholarly journals Validation and Evaluation of COSINE Software Package Based on the Operation Data of Third Generation Passive Pressurized Water Reactor

2021 ◽  
Author(s):  
Weibin Zhang ◽  
Chenglin Zhu ◽  
Qiao Zhang ◽  
Linlin Xu ◽  
Guoping Quan

According to the historical experience of international nuclear power software development and the requirements of relevant guidelines at home and abroad, a large number of experiments and theoretical work must be carried out to verify and confirm the empirical formulas, models and calculation methods used in the software and evaluate the models related to safety evaluation in order to make the software be applied to the design and analysis of nuclear power plants. Validation and evaluation is the most important key link in the process of nuclear power software development, which is heavy workload and difficult, and needs a lot of actual power plant operation data. This paper proposed a research on the validation and evaluation of the COSINE software package’s calculation capability and accuracy based on the operation data of the third generation passive PWR (Pressurized Water Reactor) AP1000. The comparison results between the operation limit parameters of the nuclear power plant including critical boron concentration, heat pipe factor of nuclear enthalpy rise, heat flux hot spot factor and AO (Axial Offset) showed that the data calculated by COSINE met the running requirements of the nuclear power plant, and the calculation accuracy keeps also in a good way.

Radiocarbon ◽  
1995 ◽  
Vol 37 (2) ◽  
pp. 497-504 ◽  
Author(s):  
Mihály Veres ◽  
Ede Hertelendi ◽  
György Uchrin ◽  
Eszter Csaba ◽  
István Barnabás ◽  
...  

We measured airborne releases of 14C from the Paks Pressurized Water Reactor (PWR) Nuclear Power Plant (NPP). Two continuous stack samplers collect 14C in 14CO2 and 14CnHm chemical forms. 14C activities were measured using two techniques; environmental air samples of lower activities were analyzed by proportional counting, stack samples were measured by liquid scintillation counting. 14C concentration of air in the stack varies between 80 and 200 Bqm−3. The average normalized yearly discharge rates for 1988–1993 were 0.74 TBqGW−1ey−1 for hydrocarbons and 0.06 TBqGW−1ey−1 for CO2. The discharge rate from Paks Nuclear Power Plant is about four times higher than the mean discharge value of a typical Western European PWR NPP. The higher 14C production may be apportioned to the higher level of nitrogen impurities in the primary coolant. Monitoring the long-term average excess from the NPP gave D14C = 3.5‰ for CO2 and D14C = 20‰ for hydrocarbons. We determined 14C activity concentration in the primary coolant to be ca. 4 kBq liter−1. The 14C activity concentrations of spent mixed bed ion exchange resins vary between 1.2 and 5.3 MBqkg−1 dry weight.


2021 ◽  
Author(s):  
Jin Feng Huang

Abstract After Fukushima nuclear power plant disaster, the efforts to overcome these defects of PWRs were carried out, such as replacing the cladding and fuel materials. One of these feasible efforts is using Fully Ceramic Microencapsulated (FCM) fuel replacement traditional UO2 pellets fuel into PWR. The FCM fuels are composed of Tri-structural-isotropic (TRISO) particles embedded in silicon carbide matrix. The TRISO fuel can hold its containment integrity and without fission production releases under the design temperature limit of 1600 °C. Furthermore, the silicon carbide matrix will benefit the thermal conductivity, radiation damage resistance, environmental stability and proliferation resistance. Consequently, the safety of the reactor could be significantly improved with FCM fuel instead of the conventional UO2 pellet fuel in PWR. We also analyzed the temperature distribution for the FCM fuel compared the traditional UO2 pellets, the calculation indicated that the centerline temperature is lower than UO2 pellets due to FCM higher thermal conductivity. The calculation demonstrated that, utilizing FCM replacement of conventional UO2 fuel rod is feasible and more security in a small pressurized water reactor. In this paper, a small pressurized water reactor utilizing FCM fuel is considered. A 17 × 17 fuel assemblies with Zircalloy cladding was applied in conceptual design through a preliminary neutronics and thermal hydraulics analysis. The reactor physics is accomplished, including the refuel cycle length, the effective multiplication factor, power distribution analysis being discussed. The Soluble Boron Free (SBF) concepts are introduced in small PWR, as a result, it makes the nuclear power plant more simpler and economical. FCM fuel loading has a very high excess reactivity at the beginning of reactor core life, and it is important to flat reactivity curve during operation, or to minimize excess reactivity during the core life. Consequently, conventional burnable poison configurations were introduced to suppress excess reactivity control at beginning of cycle.


2014 ◽  
Vol 2014 ◽  
pp. 1-7 ◽  
Author(s):  
Said M. A. Ibrahim ◽  
Mohamed M. A. Ibrahim ◽  
Sami. I. Attia

This paper presents a methodology for studying the impact of the cooling water temperature on the thermal performance of a proposed pressurized water reactor nuclear power plant (PWR NPP) through the thermodynamic analysis based on the thermodynamic laws to gain some new aspects into the plant performance. The main findings of this study are that an increase of one degree Celsius in temperature of the coolant extracted from environment is forecasted to decrease by 0.39293 and 0.16% in the power output and the thermal efficiency of the nuclear-power plant considered, respectively.


Radiocarbon ◽  
1997 ◽  
Vol 39 (3) ◽  
pp. 285-292 ◽  
Author(s):  
Barbara Vokal ◽  
Ivan Kobal

Since 1991, radiocarbon analyses of exhaust air have been part of the regular radioactivity monitoring program at the Krško Nuclear Power Plant (NPP), a Westinghouse 632 MWe pressurized water reactor (PWR). Activity of CO2 and hydrocarbons has been identified; the former contributes ca. 43%. A normalized release of total 14C of 0.219 TBqGWe−1a−1 was obtained. Indoor air 14C concentrations in selected rooms inside the plant have generally been <5 Bq m−3, although rare peaks of >1000 Bq m−3 may be reached. Tree rings have shown slight enhanced 14C activity due to the operation of the plant.


Sign in / Sign up

Export Citation Format

Share Document