scholarly journals Minor Axis Internal Diameter at End Ventricular Systole

2020 ◽  
Author(s):  
1955 ◽  
Vol 184 (1) ◽  
pp. 188-194 ◽  
Author(s):  
Robert F. Rushmer

The initial phase of ventricular systole has been termed the phase of isometric contraction because all the cardiac valves are closed while the pressure is rapidly elevated. Cyclic changes in the dimensions of the left ventricle, recorded by gauges applied directly to the ventricular walls have consistently exhibited an abrupt expansion of the internal diameter, external circumference and external length of the chamber at the onset of systole. Apparently the longitudinal axis of the chamber is abruptly shortened by early contraction of papillary muscles and trabeculae carnae. The lateral walls bulge outward so that the chamber assumes a more spherical configuration as the internal pressure rises. It is doubtful that any of the myocardial fibers actually contract without a change in length, and the term "isometric contraction" is not appropriate for this phase. The initial stage of ventricular systole is actually a period of asynchronous contraction or sphericalization.


1995 ◽  
Vol 73 (05) ◽  
pp. 850-856 ◽  
Author(s):  
F D Rubens ◽  
D W Perry ◽  
M W C Hatton ◽  
P D Bishop ◽  
M A Packham ◽  
...  

SummaryPlatelet accumulation on small- and medium-calibre vascular grafts plays a significant role in graft occlusion. We examined platelet accumulation on the surface of fibrin-coated polyethylene tubing (internal diameter 0.17 cm) during 10 min of flow (l0ml/min) at high wall shear rate (764 s-1). Washed platelets labelled with 51Cr were resuspended in Tyrode solution containing albumin, apyrase and red blood cells (hematocrit 40%). When the thrombin that was used to form the fibrin-coated surface was inactivated with FPRCH2C1 before perfusion of the tubes with the platelet:red blood cell suspension, the accumulation of platelets was 59,840 ± 27,960 platelets per mm2, whereas accumulation on fibrin with residual active thrombin was 316,750 ± 32,560 platelets per mm2 (n = 4). When the fibrin on the surface was cross-linked by including recombinant factor XIII (rFXIII) in the fibrinogen solution used to prepare the fibrin-coated surface, platelet accumulation, after thrombin neutralization, was reduced by the cross-linking from 46,974 ± 9702 to 36,818 ± 7964 platelets per mm2 (n = 12, p <0.01). Platelet accumulation on tubes coated with D-dimer was ten times less than on tubes coated with D-domain; this finding also supports the observation that cross-linking of fibrin with the formation of γ-γ dimers reduces platelet accumulation on the fibrin-coated surface. Thrombin-activated platelets themselves were shown to cross-link fibrin when they had adhered to it during perfusion, or in a static system in which thrombin was used to form clots from FXIII-free fibrinogen in the presence of platelets. Thus, cross-linking of fibrin by FXIII in plasma or from platelets probably decreases the reactivity of the fibrin-containing thrombi to platelets by altering the lysine residue at or near the platelet-binding site of each of the γ-chains of the fibrinogen which was converted into the fibrin of these thrombi.


2020 ◽  
Vol 16 ◽  
Author(s):  
Chiara Fanali ◽  
Giovanni D’Orazio ◽  
Alessandra Gentili ◽  
Salvatore Fanali

: In this review paper, miniaturized techniques, including both electromigration and liquid chromatographic ones, have been considered discussing their main features in the analytical field for the separation and analysis of nonsteroidal anti-inflammatory drugs (NSAIDs). In capillary electrophoresis (CE) and nano-liquid chromatography (nano-LC), separation are performed in capillaries with internal diameter (I.D.) lower than 100 m and therefore flow rates in the range 100- 1000 nL/min are applied. Therefore due to the low flow rate, high mass sensitivity can be obtained. Usually conventional UV detectors are used on-line; however these techniques can be coupled with mass spectrometry (MS). CE and nano-LC have been also applied to the separation of NSAIDs using silica stationary phases (SP) modified with C18 promoting interaction with analytes mainly based on hydrophobic interaction. In addition the use of chiral SP resulted effective for the chiral resolution of these compounds. In addition to silica phases, monolithic (both organic and inorganic) material has also been used. Although most of the presented studies aimed to demonstrate the usefulness of the considered microfluidic techniques, some applications to real samples have also been reported.


1879 ◽  
Vol 29 (196-199) ◽  
pp. 472-482 ◽  

In order to investigate this subject, I devised and constructed the following apparatus :—A and B are two thin glass basins, 81 millims. internal diameter (= 5,153 sq. millims. of mercury surface), and 6·0 centims. deep; each containing a layer of mercury about 1·0 centim. deep, covered by a layer, about 3 centims. deep, of the aqueous solution to be examined.


Sign in / Sign up

Export Citation Format

Share Document