scholarly journals Comparison of Pericardial Patch Graft Thickness for Glaucoma Implant, Using Anterior Segment Optical Coherence Tomography

2020 ◽  
Vol 61 (5) ◽  
pp. 532-537
Author(s):  
Min Gu Kang ◽  
Jae Shin Suh ◽  
Youn Gon Lee ◽  
Young Hoon Hwang
2011 ◽  
Vol 36 (9) ◽  
pp. 782-786 ◽  
Author(s):  
Ahmad Kheirkhah ◽  
Mohsen Adelpour ◽  
Mojgan Nikdel ◽  
Reza Ghaffari ◽  
Hamed Ghassemi ◽  
...  

2018 ◽  
Author(s):  
Yujin Zhao ◽  
Hong Zhuang ◽  
Jiaxu Hong ◽  
Lijia Tian ◽  
Jianjiang Xu

Abstract Background: Previous studies of internal graft-host malappositions have not dealt with the precise ways in which each wound malapposition affected post-keratoplasty visual outcomes. In this study, reviewing our postsurgical keratoconic patients using anterior segment optical coherence tomography (AS-OCT) to evaluate the correlation between characteristics of the graft-host interface (GHI) and visual outcomes was aimed. Methods: Correlations between characteristics of GHI and the postsurgical visual outcomes, including logarithm of minimum angle of resolution best-corrected visual acuity (logMAR BCVA), spherical equivalent diopter (SE), diopter of spherical power (DS), diopter of cylindrical power (DC), and keratometric astigmatism, were evaluated of 45 eyes (patients). Results: The graft-host touch (GHT) varied with different alignment patterns. LogMAR BCVA correlated positively with GHT (r=0.32, P=0.030) and junctional graft thickness (Tg) (r=0.49, P=0.001). SE had positive correlation with frequency of step [F (step)] (r=0.46, P=0.001), graft step [F (graft step)] (r=0.40, P=0.028), total prevalence of malapposition proportion (Pm) (r=0.35, P=0.018), size of malapposition (Sm) (r=0.31, P=0.037), Tg (r=0.03, P=0.022), disparity between junctional graft and host thickness (|Tg-Th|) (r=0.40, P=0.007), and correlated negatively with GHT (r=-0.34, P=0.021). Similar results were acquired in DS. Keratometric astigmatism was found to correlate positively with Sm (r=0.30, P=0.047). Conclusion: In keratoconic eyes, corneal keratometric astigmatism increased by 0.017 with Sm. LogMAR BCVA increased by 0.001 with both GHT and Tg. Investigation of the visions for keratoconus patients. Our study might have potential reference value for future technological promotion.


2018 ◽  
Vol 1 ◽  
pp. 3
Author(s):  
Joshua S Agranat ◽  
Yoshihiro Yonekawa

Iris pigment epithelial (IPE) cysts are a subset of iris cysts that arise from the IPE. They are spontaneously erupting epithelial-lined cavities that are found in various anatomic locations of the iris, including the iris pupillary margin, midzone, periphery, and free floating in the vitreous or anterior chamber. We report the case of an asymptomatic 13-year-old boy with an incidental finding of a dislodged anterior chamber cyst diagnosed on routine examination. Modern multimodal image analysis of the cyst including anterior segment optical coherence tomography and ultrasound biomicroscopy (UBM) was utilized to characterize the microstructural anatomy of the lesion. The patient was managed conservatively without complications. Cysts of the IPE typically do not affect vision or ocular health and can be monitored and observed after ascertaining no associated malignancy. Initial diagnostic investigation can include UBM and anterior segment optical coherence tomography. Intervention should be reserved only for cases where the cyst growth leads to obstruction of the visual axis and/or other secondary complications.


2011 ◽  
Vol 151 (3) ◽  
pp. 406-412.e2 ◽  
Author(s):  
Dhivya Ashok Kumar ◽  
Amar Agarwal ◽  
Gaurav Prakash ◽  
Soosan Jacob ◽  
Yoga Saravanan ◽  
...  

2021 ◽  
Vol 10 (2) ◽  
pp. 231
Author(s):  
Giacinto Triolo ◽  
Piero Barboni ◽  
Giacomo Savini ◽  
Francesco De Gaetano ◽  
Gaspare Monaco ◽  
...  

The introduction of anterior-segment optical-coherence tomography (AS-OCT) has led to improved assessments of the anatomy of the iridocorneal-angle and diagnoses of several mechanisms of angle closure which often result in raised intraocular pressure (IOP). Continuous advancements in AS-OCT technology and software, along with an extensive research in the field, have resulted in a wide range of possible parameters that may be used to diagnose and follow up on patients with this spectrum of diseases. However, the clinical relevance of such variables needs to be explored thoroughly. The aim of the present review is to summarize the current evidence supporting the use of AS-OCT for the diagnosis and follow-up of several iridocorneal-angle and anterior-chamber alterations, focusing on the advantages and downsides of this technology.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Michael Mimouni ◽  
Martin Kronschläger ◽  
Manuel Ruiss ◽  
Oliver Findl

Abstract Background Remnant interface fluid following Descemet stripping automated endothelial keratoplasty (DSAEK) is associated with postoperative detachments. The aim of this study was to assess outcomes of intraoperative optical coherence tomography (iOCT) guided meticulous peripheral corneal sweeping for removal of interface fluid during ultra-thin (UT) DSAEK. Methods This retrospective study included all eyes underwent iOCT guided UT-DSAEK from October 2016 to February 2018 at the Hanusch Hospital, Vienna, Austria. Peripheral meticulous corneal sweeping was performed to remove excess fluid. Central graft thickness (CGT) was measured prior to surgery, after graft bubbling and after corneal sweeping. Remnant interface fluid rates were compared between eyes that underwent rebubbling and those that did not. Results Overall, 28 eyes of 28 patients with a mean age of 73.9 ± 10.0 years were included. An iOCT guided meticulous peripheral sweeping was performed in 89.3% (n = 25) of the cases. Following 84% (n = 21) of the peripheral sweeping performed, remnant fluid was no longer identified. Following peripheral sweeping the interface fluid height was reduced from 17.31 ± 15.96 μm to 3.46 ± 9.52 μm (p < 0.001) and CGT was reduced by 7% (p < 0.001). Rebubbling was performed in 17.9% (n = 5) of the cases. The rebubbling group had a greater proportion of patients that had remnant fluid identified with iOCT at the end of surgery despite meticulous peripheral sweeping (60.0% versus 4.4%, p = 0.01). Conclusion The iOCT identified subclinical remnant fluid in nearly 90% of UT-DSAEK cases. An iOCT guided peripheral corneal sweeping led to resolution of interface fluid in a majority of cases. Eyes with persistent remnant fluid despite peripheral corneal sweeping are more likely to require subsequent rebubbling.


Author(s):  
Ágnes Füst ◽  
Jeannette Tóth ◽  
László Imre ◽  
Zoltán Zsolt Nagy

Abstract Purpose To observe and describe the anterior segment optical coherence tomography features of limbally localised non-malignant epithelial mass lesions Methods Thirteen patients (age: 66.9 ± 16.3 years) with conjunctival mass suggesting ocular surface squamous neoplasia with biomicroscopic examination were imaged using anterior segment ocular coherence tomography (anterior segment optical coherence tomography)/Cirrus HD-OCT, Model 4000, Carl Zeiss Meditec, Inc., Dublin, CA, and Spectralis HRA + OCT system, Heidelberg Engineering, Vista, CA/. Cases with ocular surface squamous neoplasia-like anterior segment optical coherence tomography (hyperreflective, thickened epithelium and an abrupt transition from normal to abnormal) were included in the study. Maximal thickness of the epithelium was measured. Histological diagnosis was gained from an excisional or incisional biopsy or impression cytology specimens. Results In six patients (age: 68.5 ± 15.4 years) with ocular surface squamous neoplasia-like anterior segment optical coherence tomography features, the histological diagnosis was other than ocular surface squamous neoplasia (papilloma, parakeratosis and a keratotic plaque with mild dysplasia), and ocular surface squamous neoplasia in seven cases (age: 65.6 ± 18.0 years). The maximal epithelial thickness was between 250 and 859 µm in non-ocular surface squamous neoplasia cases and between 252 and 596 µm in ocular surface squamous neoplasia cases. Conclusion Non-malignant epithelial lesions can mimic ocular surface squamous neoplasia on anterior segment optical coherence tomography.


Sign in / Sign up

Export Citation Format

Share Document