Natural Lonizing System of Electrical Protection against Atmospheric Discharges (Lightning)

Author(s):  
L. Cabareda.
2018 ◽  
Vol 180 ◽  
pp. 05006
Author(s):  
Zofia Wróbel

The valuation of the risk of losses makes easy the correct estimation of resulted threats as a result of atmospheric discharges and harms connected to them. Qualifying the need of lightning protection use for the object, we ought to take into account the risk R for the object and for the public services devices. In every case of examining risks we ought to fulfill: the identification of components RX forming the risk, counting the identified components of the risk RX, the entire risk R, identify the tolerated risk RT and compare the risk R with the tolerated value RT. As a result of such analysis we can come to a decision about the use of protection resources. In the report was realized the risk analysis of devices damages for a chosen object - the signal box with installed station - relaying devices of the railway traffic controlling with a computer adjustable control panel. From the realized analysis results that DEHN Risk Tool is a useful tool for the risk analysis of lightning losses in buildings, making possible the improvement of the calculations process, especially in the range of the choice of proper protection resources.


2016 ◽  
Vol 58 (12) ◽  
pp. 1330-1335
Author(s):  
Yu. A. Plastinin ◽  
I. Yu. Skryabysheva

2021 ◽  
Vol 39 (2) ◽  
pp. 321-326
Author(s):  
Karol Martynski ◽  
Jan Blecki ◽  
Roman Wronowski ◽  
Andrzej Kulak ◽  
Janusz Mlynarczyk ◽  
...  

Abstract. Mesoscale convective systems (MCSs) are especially visible in the summertime when there is an advection of warm maritime air from the west. Advection of air masses is enriched by water vapour, the source of which can be found over the Mediterranean Sea. In propitious atmospheric conditions, and thus significant convection, atmospheric instability or strong vertical thermal gradient leads to the development of strong thunderstorm systems. In this paper, we discuss one case of MCSs, which generated a significant amount of +CG (cloud-to-ground), −CG and intracloud (IC) discharges. We have focused on the ELF (extremely low frequency; < 1 kHz) electromagnetic field measurements, since they allow us to compute the charge moments of atmospheric discharges. Identification of the MCSs is a complex process, due to many variables which have to be taken into account. For our research, we took into consideration a few tools, such as cloud reflectivity, atmospheric soundings and data provided by PERUN (Polish system of the discharge localisation system), which operates in a very high frequency (VHF) range (113.5–114.5 MHz). Combining the above-described measurement systems and tools, we identified a MCS which occurred in Poland on 23 July 2009. Furthermore, it fulfilled our requirements since the thunderstorm crossed the path of the DEMETER (Detection of Electro-Magnetic Emissions Transmitted from Earthquake Regions) overpass.


Sign in / Sign up

Export Citation Format

Share Document