scholarly journals The Imprinted PARAFILM as a New Carrier Material for Dried Plasma Spots (DPSs) Utilizing Desorption Electrospray Ionization Mass Spectrometry (DESI-MS) in Phospholipidomics

2021 ◽  
Vol 9 ◽  
Author(s):  
Jiansong Chen ◽  
Yue Hu ◽  
Congxiang Shao ◽  
Haiyun Zhou ◽  
Zhiyue Lv

The application of desorption electrospray ionization mass spectrometry (DESI-MS) and dried blood spot (DBS) sampling has been successfully implemented several times. However, the difficulty of combining DBS sampling with DESI-MS is still the carrier material used for the blood samples. In this study, a new, easily obtained, and cost-effective carrier substrate for dried plasma spot (DPS) sampling and DESI-MS analysis and its application in phospholipidomics studies was described. First, the effects of several carrier materials, including cellulose-based materials (31 ET paper and filter paper) and non-cellulose-based materials (PARAFILM and its shape-modified material, PTFE-printed glass slide and polyvinylidene fluoride film), were tested. Second, a method combining DPS sampling with DESI-MS for phospholipidomics analysis was established, and parameters affecting compound signal intensities, such as sample volume and sprayer solvent system, were optimized. In conclusion, the total signal intensity obtained from shape-modified PARAFILM was the strongest. The suitable plasma sample volume deposited on PARAFILM carriers was 5 μl, and acetonitrile (ACN) was recommended as the optimal spray solvent for phospholipid (PL) profiling. Repeatability (87.5% of compounds with CV < 30%) and stability for data acquisition (48 h) were confirmed. Finally, the developed method was applied in phospholipidomics analysis of schistosomiasis, and a distinguished classification between control mice and infected mice was observed by using multivariate pattern recognition analysis, confirming the practical application of this new carrier material for DPS sampling and DESI-MS analysis. Compared with a previously reported method, the rapid metabolomics screening approach based on the implementation of DPS sampling coupled with the DESI-MS instrument developed in this study has increased analyte sensitivity, which may promote its further application in clinical studies.

2013 ◽  
Vol 405 (24) ◽  
pp. 7643-7651 ◽  
Author(s):  
Lívia Botelho de Abreu ◽  
Rodinei Augusti ◽  
Lucas Schmidt ◽  
Valderi Luiz Dressler ◽  
Erico Marlon de Moraes Flores ◽  
...  

2020 ◽  
Vol 12 (28) ◽  
pp. 3654-3669
Author(s):  
Tiago Jose P. Sobreira ◽  
Larisa Avramova ◽  
Botond Szilagyi ◽  
David L. Logsdon ◽  
Bradley P. Loren ◽  
...  

Implementation of a novel method for high-throughput screening of reactions in microdroplets. The reaction and analysis steps are performed simultaneously using desorption electrospray ionization mass spectrometry (DESI-MS) at a rate of up to 1 reaction mixture per second.


2020 ◽  
Vol 412 (6) ◽  
pp. 1251-1262 ◽  
Author(s):  
Fernanda Bertuccez Cordeiro ◽  
Alan K. Jarmusch ◽  
Marisol León ◽  
Christina Ramires Ferreira ◽  
Valentina Pirro ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document