scholarly journals Assessment of Delivery Quality Assurance for Stereotactic Radiosurgery With Cyberknife

2021 ◽  
Vol 11 ◽  
Author(s):  
Jun Li ◽  
Xile Zhang ◽  
Yuxi Pan ◽  
Hongqing Zhuang ◽  
Junjie Wang ◽  
...  

PurposeThe purpose of this study is to establish and assess a practical delivery quality assurance method for stereotactic radiosurgery with Cyberknife by analyzing the geometric and dosimetric accuracies obtained using a PTW31016 PinPoint ionization chamber and EBT3 films. Moreover, this study also explores the relationship between the parameters of plan complexity, target volume, and deliverability parameters and provides a valuable reference for improving plan optimization and validation.MethodsOne hundred fifty cases of delivery quality assurance plans were performed on Cyberknife to assess point dose and planar dose distribution, respectively, using a PTW31016 PinPoint ionization chamber and Gafchromic EBT3 films. The measured chamber doses were compared with the planned mean doses in the sensitive volume of the chamber, and the measured planar doses were compared with the calculated dose distribution using gamma index analysis. The gamma passing rates were evaluated using the criteria of 3%/1 mm and 2%/2 mm. The statistical significance of the correlations between the complexity metrics, target volume, and the gamma passing rate were analyzed using Spearman’s rank correlation coefficient.ResultsFor point dose comparison, the averaged dose differences (± standard deviations) were 1.6 ± 0.73% for all the cases. For planar dose distribution, the mean gamma passing rate for 3%/1 mm, and 2%/2 mm evaluation criteria were 94.26% ± 1.89%, and 93.86% ± 2.16%, respectively. The gamma passing rates were higher than 90% for all the delivery quality assurance plans with the criteria of 3%/1 mm and 2%/2 mm. The difference in point dose was lowly correlated with volume of PTV, number of beams, and treatment time for 150 DQA plans, and highly correlated with volume of PTV for 18 DQA plans of small target. DQA gamma passing rate (2%/2 mm) was a moderate significant correlation for the number of nodes, number of beams and treatment time, and a low correlation with MU.ConclusionPTW31016 PinPoint ionization chamber and EBT3 film can be used for routine Cyberknife delivery quality assurance. The point dose difference should be within 3%. The gamma passing rate should be higher than 90% for the criteria of 3%/1 mm and 2%/2 mm. In addition, the plan complexity and PTV volume were found to have some influence on the plan deliverability.

2017 ◽  
Vol 23 (4) ◽  
pp. 93-97 ◽  
Author(s):  
Maria Atiq ◽  
Atia Atiq ◽  
Khalid Iqbal ◽  
Quratul ain Shamsi ◽  
Farah Andleeb ◽  
...  

Abstract Objective: The Gamma Index is prerequisite to estimate point-by-point difference between measured and calculated dose distribution in terms of both Distance to Agreement (DTA) and Dose Difference (DD). This study aims to inquire what percentage of pixels passing a certain criteria assure a good quality plan and suggest gamma index as efficient mechanism for dose verification of Simultaneous Integrated Boost Intensity Modulated Radiotherapy plans. Method: In this study, dose was calculated for 14 head and neck patients and IMRT Quality Assurance was performed with portal dosimetry using the Eclipse treatment planning system. Eclipse software has a Gamma analysis function to compare measured and calculated dose distribution. Plans of this study were deemed acceptable when passing rate was 95% using tolerance for Distance to agreement (DTA) as 3mm and Dose Difference (DD) as 5%. Result and Conclusion: Thirteen cases pass tolerance criteria of 95% set by our institution. Confidence Limit for DD is 9.3% and for gamma criteria our local CL came out to be 2.0% (i.e., 98.0% passing). Lack of correlation was found between DD and γ passing rate with R2 of 0.0509. Our findings underline the importance of gamma analysis method to predict the quality of dose calculation. Passing rate of 95% is achieved in 93% of cases which is adequate level of accuracy for analyzed plans thus assuring the robustness of SIB IMRT treatment technique. This study can be extended to investigate gamma criteria of 5%/3mm for different tumor localities and to explore confidence limit on target volumes of small extent and simple geometry.


2020 ◽  
Vol 19 ◽  
pp. 153303382094581
Author(s):  
Du Tang ◽  
Zhen Yang ◽  
Xunzhang Dai ◽  
Ying Cao

Purpose: To evaluate the performance of Delta4DVH Anatomy in patient-specific intensity-modulated radiotherapy quality assurance. Materials and Methods: Dose comparisons were performed between Anatomy doses calculated with treatment plan dose measured modification and pencil beam algorithms, treatment planning system doses, film doses, and ion chamber measured doses in homogeneous and inhomogeneous geometries. The sensitivity of Anatomy doses to machine errors and output calibration errors was also investigated. Results: For a Volumetric Modulated Arc Therapy (VMAT) plan evaluated on the Delta4 geometry, the conventional gamma passing rate was 99.6%. For a water-equivalent slab geometry, good agreements were found between dose profiles in film, treatment planning system, and Anatomy treatment plan dose measured modification and pencil beam calculations. Gamma passing rate for Anatomy treatment plan dose measured modification and pencil beam doses versus treatment planning system doses was 100%. However, gamma passing rate dropped to 97.2% and 96% for treatment plan dose measured modification and pencil beam calculations in inhomogeneous head & neck phantom, respectively. For the 10 patients’ quality assurance plans, good agreements were found between ion chamber measured doses and the planned ones (deviation: 0.09% ± 1.17%). The averaged gamma passing rate for conventional and Anatomy treatment plan dose measured modification and pencil beam gamma analyses in Delta4 geometry was 99.6% ± 0.89%, 98.54% ± 1.60%, and 98.95% ± 1.27%, respectively, higher than averaged gamma passing rate of 97.75% ± 1.23% and 93.04% ± 2.69% for treatment plan dose measured modification and pencil beam in patients’ geometries, respectively. Anatomy treatment plan dose measured modification dose profiles agreed well with those in treatment planning system for both Delta4 and patients’ geometries, while pencil beam doses demonstrated substantial disagreement in patients’ geometries when compared to treatment planning system doses. Both treatment planning system doses are sensitive to multileaf collimator and monitor unit (MU) errors for high and medium dose metrics but not sensitive to the gantry and collimator rotation error smaller than 3°. Conclusions: The new Delta4DVH Anatomy with treatment plan dose measured modification algorithm is a useful tool for the anatomy-based patient-specific quality assurance. Cautions should be taken when using pencil beam algorithm due to its limitations in handling heterogeneity and in high-dose gradient regions.


2013 ◽  
Vol 31 (31_suppl) ◽  
pp. 81-81 ◽  
Author(s):  
Wolfram Laub ◽  
Charles R. Thomas

81 Background: Patient-specific quality assurance measurements are time consuming and Gamma pass/fail criteria are often picked based on typical criteria used for IMRT QA measurements in the past. The questions needs to be asked if with these criteria QA plans could still show clinically significant deviations from the treatment plan calculated and how we should be doing QA for treatment delivery of complex treatment plans. In our study DICOM files of clinical Rapidarc plans were modified with in-house developed software to mimic leaf alignment errors and gravitation shifts. The Octavius 2D-ARRAY (PTW-Freiburg) and the Delta4 device (Scandidos) were used to investigate the effect of the simulated errors on the passing rate of quality assurance results. The manipulated Rapidarc plans were recalculated on patient CT scans in Eclipse. Methods: Three different types of errors were simulated and applied to five prostate (two arcs), three 2-arc head and neck cases and three 3-arc head and neck cases. The MLC modifications were: (1) both MLC banks are opened by 0.25mm, 0.50mm and 1.00mm in opposing directions resulting in larger fields, (2) both MLC banks are closed by 0.10mm, 0.25mm and 0.50mm, (3) both MLC banks are shifted in the same direction for lateral gantry angles to simulate effects of gravitational forces onto the leaves by 1mm, 2mm and 3mm, (4) 25%, 50% 70% and 100% of all active leaves are shifted by 3mm as in (3). QA evaluations were performed according to a gamma-index criterion of 3mm and 3% as well as 2mm and 2%. Results: All unmodified plans and the majority of the plans with the smallest modification pass the gamma-index criterion of 2%/2mm with >90%. After that the passing rate drops below 90%. For the largest modifications passing rates were typically below 85%. The Delta4 is generally more sensitive and the passing rate for modified plans drops below 90% earlier and more drastically. With the standard criteria (3mm, 3%) even the largest modifications would satisfy a >90% passing rate. Conclusions: A stricter gamma-index (2mm, 2%) is necessary in order to detect MLC positional errors and a passing rate of >90% should be expected. Clinical pass/fail criteria need to be developed.


1997 ◽  
Vol 53 (1) ◽  
pp. 238
Author(s):  
Hiroki Ohtani ◽  
Toraji Irifune ◽  
Masahiro Fukushi ◽  
Yoshiyuki Nyui ◽  
Toh Jui Wong ◽  
...  

2021 ◽  
Vol 19 (11) ◽  
pp. 141-150
Author(s):  
Ahmed H. Waheeb ◽  
Zeinab Eltaher ◽  
Mohamed N. Yassin ◽  
Magdy M. Khalil

This study examined the gamma passing rate (GPR) consistency during applying different kinds of gamma analyses and dosimeters to IMRT. Methods: Import treatment protocols for QA phantom irradiation have been recalculated. A gamma analysis was used for comparing the measured and calculated dose distribution of IMRT for different gamma criteria (2%/2mm, 3%/3mm, 4%/4mm, 3%/5mm, 3%/5mm). These criteria are evaluated when 5%, 10%, or 15% of the dose distribution is suppressed. Measured and calculated dose distribution was evaluated with gamma analysis to dose difference (DD) with DTA criteria (distance to agreement). IMRT QA plans to 25 patients from various sites were formed with the Varian Eclipse treatment planning system. Results: Results indicate different diverse hardware and software combinations show varied levels of agreement with expected analysis for the same pass-rate criterion. For a dosimetry audit of the IMRT technique, an EPID detector is superior to conventional methods comparable to Gafchromic EPT3 film and 2D array due to cost, time-consuming, and set up error to get result analysis. The gamma passing rate (GPR) average is increased by increasing the low-dose threshold for different dosimetric tools. For EPID, regardless of the gamma criterion employed, the %GP does not appear to be dependent on the low-dose threshold values (5%-15%) because it indicates that fulfilment the low-dose threshold to global normalization has little effect on patient-specific QA outcomes. Conclusions: It is concluded that GPRs differ depending on gamma, dosimetric tools, and the suppressing dose ratio. To get the best results of quality assurance, each institution should thus carefully develop its procedure for gamma analysis by defining the gamma index analysis and gamma criterion using its dosimetric tools.


Author(s):  
Meghan Koo ◽  
Johnson Darko ◽  
Ernest Osei

Abstract Background: The purpose of this study is to evaluate the effectiveness and sensitivity of the Varian portal dosimetry (PD) system as a quality assurance (QA) tool for breast intensity-modulated radiation therapy (IMRT) treatment plans. Materials and methods: Four hundred portal dose images from 200 breast cancer patient IMRT treatment plans were analysed. The images were obtained using Varian PortalVision electronic portal imaging devices (EPIDs) on Varian TrueBeam Linacs. Three patient plans were selected, and the multi-leaf collimator (MLC) positions were randomly altered by a mean of 0·5, 1, 1·5 and 2 mm with a standard deviation of 0·1 mm on 50, 75 and 100% of control points. Using the improved/global gamma calculation algorithm with a low-dose threshold of 10% in the EPID, the change in gamma passing rates for 3%/3 mm, 2%/2 mm and 1%/1 mm criterion was analysed as a function of the introduced error. The changes in the dose distributions of clinical target volume and organ at risk due to MLC positioning errors were also analysed. Results: Symmetric and asymmetric breast or chest wall plan fields are different in delivery as well as in the QA. An average gamma passing rate of 99·8 ± 0·5 is presented for 3%/3 mm symmetric plans and 96·9 ± 4·5 is presented for 3%/3 mm asymmetric plans. An average gamma passing rate of 98·4 ± 4·3 is presented for 2%/2 mm symmetric plans and 89·7 ± 9·5 is presented for 2%/2 mm asymmetric plans. A large-induced error in MLC positioning (2·0 mm, 100% of control points) results in an insignificant change in dose that would be delivered to the patient. However, EPID portal dosimetry is sensitive enough to detect even the slightest change in MLC positioning error (0·5 mm, 50% of control points). Conclusions: Stricter pre-treatment QA action levels can be established for breast IMRT plans utilising EPID. For improved sensitivity, a multigamma criteria approach is recommended. The PD tool is sensitive enough to detect MLC positioning errors that contribute to even insignificant dose changes.


2012 ◽  
Vol 103 ◽  
pp. S128
Author(s):  
A. Di Dia ◽  
C. Sini ◽  
S. Bresciani ◽  
A. Maggio ◽  
A. Miranti ◽  
...  