scholarly journals Real Color Sectioned Images and Correspondence with Ultrasound Images of the Palmar Wrist

2021 ◽  
Vol 12 (1) ◽  
pp. 299
Author(s):  
Seul Ki Kim ◽  
Mi-Sun Hur ◽  
Jin Seo Park

The aim of this study was to identify sequential changes in the actual sites and shapes of wrist structures on the high-resolution sectioned images and to compare these with those on ultrasound (US) images. These images of the wrist may yield guidelines for diagnosing various pathological lesions in the wrist. In the sectioned images of a whole cadaver body, and the images including the wrist were selected, and part of the hand was cropped. A wrist of one healthy Korean subject was scanned by ultrasonography to obtain US images of the wrist. Wrist structures were identified and labeled in detail on the sectioned images and the corresponding US images. Serial changes of the sites and shapes of the wrist structures mainly occurred in the bones, median nerve, ulnar artery, ulnar nerve, and the flexor pollicis longus tendon, along with thickening of the thenar and hypothenar muscles. The present results could provide a new guide for anatomy mapping, diagnosing, and detecting various lesions of the wrist. They can also be useful and effective for educational purposes related to interpreting US images.

Author(s):  
Paul Silvian Samuel ◽  
Khalid A Alahmari ◽  
Mohamed Adam ◽  
Ravi Shankar Reddy ◽  
Irshad Ahmad ◽  
...  

Abstract Background and Aim The adverse effects of smartphone size and weight on the hand and hand function have not been studied extensively. This study aimed to investigate the changes to the flexor pollicis longus tendon and median nerve using diagnostic ultrasound for high and low addiction smartphone users. Methodology In this cross-sectional study, 54 healthy male university students were divided into two groups according to the Smartphone Addiction Scale: high and low users. Demographic data, hand grip strength (kg), pinch strength (kg), and smartphone weight, length and width were measured and recorded. Diagnostic ultrasound examination determined the cross-sectional area of the median nerve (mm2) and flexor pollicis longus tendon (mm2) of the dominant and non-dominant hand. Result The cross-sectional area of the median nerve was significantly higher in the high-user group (7.4±1.3 mm2) than the low-user group (6.7±1.0 mm2). The correlation of phone weight, length and width with median nerve area was respectively positive, higher and significant (0.718, 0.747, and 0.733; p<0.05). The flexor pollicis longus tendon in the mid-thenar region was moderately positively correlated with phone length (0.430; p<0.02) for high addiction smartphone users. Conclusion The findings of the current study demonstrates that change to the median nerve and flexor pollicis longus tendon, could be linked to the width, weight and length of the smartphone and high addiction.


2009 ◽  
Vol 34 (4) ◽  
pp. 471-474 ◽  
Author(s):  
J. A. CASALETTO ◽  
D. MACHIN ◽  
R. LEUNG ◽  
D. J. BROWN

Palmar plate fixation of distal radial fractures is becoming a standard treatment for this common injury. Ruptures of the extensor pollicis longus tendon have been reported in 8.6% of cases after this procedure. Although palmar plate fixation has also been associated with flexor pollicis longus (FPL) tendon problems, the majority of reported cases pre-date the use of newer anatomically precontoured locking plates. In this paper seven cases of FPL rupture are presented. This complication does not appear to be unique to one type of implant. The possible aetiologies for FPL ruptures are discussed and ways to reduce the incidence of this complication are suggested.