scholarly journals Effectiveness of a Selective Etching Technique in Reducing White Spots Formation around Lingual Brackets: A Prospective Cohort Clinical Study

Coatings ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 572
Author(s):  
Domenico Dalessandri ◽  
Marino Bindi ◽  
Francesca Massetti ◽  
Gaetano Isola ◽  
Marco Migliorati ◽  
...  

The risk of developing white spot lesions (WSLs) after orthodontic treatment with lingual brackets is generally considered lower than with labial ones, even if plaque accumulation is frequently higher due to the increased difficulty level in oral hygiene maintenance. In this prospective clinical study, selective enamel etching technique effectiveness in reducing plaque accumulation and WSLs was tested. Thirty patients were bonded with a split-mouth approach: two randomly selected opposite quadrants were used as the test sides, using customized plastic etching guides, and the other two as control sides, applying traditional direct etching methods. The plaque presence around the braces was recorded after 1, 3, 6, and 12 months according to a lingual plaque accumulation index (LPAI), as was the presence of WSLs. PAI measured values were significantly higher in the control sides during the observation period. Test and control sides differed significantly for new WSL onset only after 12 months of treatment. Therefore, the present research demonstrated that this guided enamel etching technique allowed for significant reduction in plaque accumulation around the lingual brackets and reduced onset of white spots after one year of treatment.

Author(s):  
Francesco Mangano ◽  
Uli Hauschild ◽  
Oleg Admakin

Background: Guided implant surgery appears to have several benefits, such as the possibility of inserting flapless implants in a prosthetically driven manner, avoiding dangerous anatomical structures. However, to date, only a few surgeons routinely use guided surgery in partially edentulous patients. Aim: To present the results obtained with tooth-supported surgical templates characterized by an innovative open design with selective support, and manufactured via a full in-office procedure with a low-cost desktop 3D printer. Methods: Over a two-year period (2016–2018), all partially edentulous patients with one to three missing teeth (in maxilla and/or mandible), referred to a private dental practice for restoration with dental implants, were considered for inclusion in this prospective clinical study. An intraoral scanner (CS 3600®, Carestream Dental) and cone beam computed tomography (CS 9300®, Carestream Dental) were used to acquire the 3D information on the patients. Guided surgery software (SMOP®, Swissmeda) was used to plan the surgeries and to design open, selective, tooth-supported templates that were fabricated with a stereolithographic (SLA) desktop 3D printer (XFAB2000®, DWS). Guided implant surgeries were performed and patients were followed for a period of one year. The study outcomes were fit and stability of surgical templates, duration (time) of surgery, intra and post-operative complications, and implant stability and survival. Results: Twenty (20) partially edentulous patients (9 males, 11 females; mean age 54.4 ± 9.4 years) were included in the study; 28 open, selective, tooth-supported templates were designed with the aim of inserting 38 implants. Among the surgical templates, 24 had optimal fit and stability, three had optimal fit and sufficient stability, and only one had inadequate fit and unsatisfactory stability and was therefore not suitable for clinical use. The average time of the intervention was 15.7 ± 5.2 min per template. No intra-operative complications were reported, but one implant was not stable at placement and had to be removed. In total, 36 implants were restored with 10 two-unit fixed partial prostheses and 16 single crowns. All implants were successfully functioning at one year, even if, in two single crowns, minor prosthetic complications (abutment screw loosening) occurred. Conclusions: Full in-office guided surgery with open, selective, tooth-supported templates seem to represent a clinically predictable surgical procedure to restore partially edentulous patients. Further studies are needed to confirm these positive outcomes.


2015 ◽  
Vol 49 (2) ◽  
pp. 128-136 ◽  
Author(s):  
Muhamed Ajanović ◽  
Adis Hamzić ◽  
Sead Redžepagić ◽  
Alma Kamber-Ćesir ◽  
Lejla Kazazić ◽  
...  

2015 ◽  
Vol 39 (5) ◽  
pp. 423-428 ◽  
Author(s):  
A Salami ◽  
T Walia ◽  
R Bashiri

Objectives: To evaluate and compare the parental satisfaction among resin composite strip crown, preveneered stainless steel crown (PVSSC) and the newly introduced pre-fabricated primary zirconia crown for restoring maxillary primary incisors. Study design: A prospective clinical study on 39 children with carious or traumatized primary maxillary incisors. They were randomly and equally distributed in three groups and received one of the full-coronal restorations. Children were recalled to evaluate and compare parental satisfaction about performance of crowns after one year through a questionnaire. Results: Parents were satisfied with all three tooth colored full-coronal restoration techniques. A significant relationship was found between colour of PVSSC (p=0.003) and durability of resin strip crowns (p=0.009) with the overall parental satisfaction levels. Parents who gave poor ratings in these two variables however rated their overall acceptance levels as being satisfied. Conclusion: Parental overall satisfaction was highest for zirconia primary crowns followed by resin composite strip crowns and lowest satisfaction was reported for pre-veneered SSCs. Parents were least satisfied with durability of resin composite strip crowns and colour of pre-veneered stainless steel crowns. However, this did not affect their overall satisfaction with these crowns.


Sign in / Sign up

Export Citation Format

Share Document