scholarly journals Stability Analysis of Shunt Active Power Filter with Predictive Closed-Loop Control of Supply Current

Energies ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 2208
Author(s):  
Agata Bielecka ◽  
Daniel Wojciechowski

This paper presents a shunt active power filter connected to the grid via an LCL coupling circuit with implemented closed-loop control. The proposed control system allows selective harmonic currents compensation up to the 50th harmonic with the utilization of a model-based predictive current controller. As the system is fully predictive, it provides high effectiveness of the harmonic reduction, which is proved by waveforms achieved in performed tests. On the other hand, the control system is prone to loss of stability. Therefore, the paper is focused on the stability analysis of the discussed control system with the additional outer control loop of the supply current with predictive control of this current. The conducted stability analysis encompasses the assessment of system stability as a function of the coupling circuit parameter identification accuracy, whose values are implemented in the current controller, as well as parameters such as the sampling frequency and proportional–integral (PI) controller coefficients. The obtained results show that the ranges of the LCL circuit parameter identification accuracy for which the system remains stable are relatively wide. However, the most effective compensation of the supply current distortion is achieved for the parameters identified correctly, and the greatest impact on the compensation quality has the value of L1 inductance.

2017 ◽  
Vol 79 (4) ◽  
Author(s):  
Sajid Hussain Qazi ◽  
Mohd Wazir Mustafa ◽  
U. Sultana ◽  
Nayyar Hussain Mirjat

The quality of power nowadays is of great concern due to increasing demand of supply and energy resources are limited, another cause is increasing penetration of nonlinear loads in the power system. In order to overcome energy supply challenges, the focus of technologists is shifting to the renewable energy side such as the wind and solar energy and so on. As such, mitigating effect of nonlinear loads have become ever important as well. In this context, various techniques have been used by researchers in past decades. Shunt active power filter (APF) have long been used to mitigate current harmonics from fixed wind turbine generator (WTG). In this study shunt APF has been applied with variable speed WTG using synchronous reference frame (SRF) for the extraction of compensation signal for APF. Gate driver signals are generated from Bang-Bang Controller (Hysteresis Band Current Controller HBCC). A MATLAB/SIMULINK based Model have been developed. The Simulation results show decreased THD levels of the system and clearly suggest the effectiveness of Shunt APF in meeting the IEEE-519 standard recommendation for harmonic levels in WTG.


2014 ◽  
Vol 62 (2) ◽  
pp. 279-286
Author(s):  
D. Buła ◽  
M. Pasko

Abstract In the paper the analysis of a three-phase hybrid active power filter stability has been presented. Configuration with a single tuned passive filter was used as an example. However, the analysis can be applied to similar configurations of hybrid filters with closed loop control. The article presents a model of the analyzed system in the frequency domain. The division of the model into two independent systems, for positive and negative components, allowed to apply the Nyquist criterion for the stability analysis in this case. As a part of the analysis, the effect of delays, control signal filter parameters, and passive filter parameters have been examined. Based on the presented stability analysis, system parameters for the experimental model of a hybrid power filter have been selected. Finally, experimental results confirming the validity of the analysis have been shown.