scholarly journals Mitochondrial Bioenergetic, Photobiomodulation and Trigeminal Branches Nerve Damage, What’s the Connection? A Review

2021 ◽  
Vol 22 (9) ◽  
pp. 4347
Author(s):  
Silvia Ravera ◽  
Esteban Colombo ◽  
Claudio Pasquale ◽  
Stefano Benedicenti ◽  
Luca Solimei ◽  
...  

Background: Injury of the trigeminal nerve in oral and maxillofacial surgery can occur. Schwann cell mitochondria are regulators in the development, maintenance and regeneration of peripheral nerve axons. Evidence shows that after the nerve injury, mitochondrial bioenergetic dysfunction occurs and is associated with pain, neuropathy and nerve regeneration deficit. A challenge for research is to individuate new therapies able to normalise mitochondrial and energetic metabolism to aid nerve recovery after damage. Photobiomodulation therapy can be an interesting candidate, because it is a technique involving cell manipulation through the photonic energy of a non-ionising light source (visible and NIR light), which produces a nonthermal therapeutic effect on the stressed tissue. Methods: The review was based on the following questions: (1) Can photo-biomodulation by red and NIR light affect mitochondrial bioenergetics? (2) Can photobiomodulation support damage to the trigeminal nerve branches? (preclinical and clinical studies), and, if yes, (3) What is the best photobiomodulatory therapy for the recovery of the trigeminal nerve branches? The papers were searched using the PubMed, Scopus and Cochrane databases. This review followed the ARRIVE-2.0, PRISMA and Cochrane RoB-2 guidelines. Results and conclusions: The reliability of photobiomodulatory event strongly bases on biological and physical-chemical evidence. Its principal player is the mitochondrion, whether its cytochromes are directly involved as a photoacceptor or indirectly through a vibrational and energetic variation of bound water: water as the photoacceptor. The 808-nm and 100 J/cm2 (0.07 W; 2.5 W/cm2; pulsed 50 Hz; 27 J per point; 80 s) on rats and 800-nm and 0.2 W/cm2 (0.2 W; 12 J/cm2; 12 J per point; 60 s, CW) on humans resulted as trustworthy therapies, which could be supported by extensive studies.

Author(s):  
Ibrahim Almutairi ◽  
Abdullah AlQarni ◽  
Mohammad Alharbi ◽  
Ahmed Almutairi ◽  
Mohammed Aldohan ◽  
...  

2020 ◽  
Vol 38 (9A) ◽  
pp. 1276-1282
Author(s):  
Nabeel I. Allawy ◽  
Amjad B. Abdulghafour

Reconstruction of the mandible after severe trauma is one of the most difficult challenges facing oral and maxillofacial surgery. The mandible is an essential element in the appearance of the human face that gives the distinctive shape of the face, holds. This paper aims to propose a methodology that allows the surgeon to perform virtual surgery by investing engineering programs to place the implant by default and with high accuracy within the mandible based on the patient's medical data. The current study involved a 35-year-old man suffering from a traffic accident in the mandible with multiple fractures of the facial bones. Basically, an identification of the steps required to perform virtual surgery and modeling images from the CBCT technology has been done by using the software proposed in the research. The implant model is designed as a mesh model, allowing the patient to return to a normal position. Moreover, an application of FEA procedures using the Solidworks simulation software to test and verify the mechanical properties of the final transplant.


Sign in / Sign up

Export Citation Format

Share Document