scholarly journals Safety and Performance of Titanium Suture Anchors Used in Knee Ligament Repair Procedures

Medicina ◽  
2021 ◽  
Vol 57 (3) ◽  
pp. 287
Author(s):  
Antonio Maestro ◽  
Iván Pipa ◽  
Nicolás Rodríguez ◽  
Carmen Toyos ◽  
Marcelino Torrontegui-Duarte ◽  
...  

Injuries to the knee ligaments can be particularly disabling in young patients, given the risk of long-term disability if adequate fixation is not achieved during initial repair. The TWINFIX™ titanium (Ti) suture anchor with ULTRABRAID™ Suture (Smith and Nephew, London, UK) was designed to secure tendon and ligament reconstructions with increased boney ingrowth at the anchor site with minimal invasive technique. This retrospective analysis looked at 33 patients (41 implants) operated with this device between 2015 and 2019 at a single institution. The average age of patients was 33.18 years (standard deviation [SD], 15.26), with an average body mass index of 24.88 (SD, 3.49). The indications were lateral extra-articular tenodesis during anterior cruciate ligament reconstruction, medial patellofemoral ligament reconstruction, quadriceps or patellar tendon repair and medial collateral ligament repair. After an average follow up of 24.3 + 6.53 months, there was no reports of clinical failure or radiographic evidence of implant failure or loosening. One patient experienced a complication unrelated to the study device, requiring manipulation under anesthesia with resolution of symptoms. This case series supports the safety and performance of this implants for the knee procedures in which its use is indicated. Additional follow-up will be required to determine whether these effects are sustained at medium- and long-term durations.

2019 ◽  
Vol 7 (10) ◽  
pp. 232596711987689 ◽  
Author(s):  
John A. Schlechter ◽  
Shawn V. Nguyen ◽  
Katie L. Fletcher

Background: Osteochondral lesions (OCLs) of the knee, whether occurring secondary to osteochondritis dissecans or a traumatic osteochondral fracture, are commonly encountered in the pediatric and adolescent population. Given the potential for healing in this population, coupled with adequate surgical reduction and stability of OCL fixation, an opportunity exists to avoid a major restorative procedure and the associated substantial costs and potential morbidity. Purpose: To analyze the outcomes of bioabsorbable fixation of OCLs in the adolescent knee at a minimum of 2 years. Study Design: Case series; Level of evidence, 4. Methods: An institutional review board–approved retrospective review was performed of patients younger than 18 years who underwent bioabsorbable fixation of an OCL of the knee with a minimum 2-year follow-up. Patient demographics, operative details, and postoperative clinical findings were detailed and recorded. All cases were performed by a single surgeon. Results: There were 38 patients treated surgically for an OCL between 2009 and 2016. Of these, 38 patients (mean age, 14.7 years) were evaluated at a mean of 59 months. OCL fixation consisted of a mean of 1.4 bioabsorbable screws and 1.5 darts. At final follow-up, mean pre- and postoperative Tegner scores were 6.6 and 6.4, respectively, while Lysholm and Pediatric International Knee Documentation Committee scores were 89.8 and 88.1, respectively. A total of 6 patients underwent secondary procedures postoperatively. One patient required a secondary procedure related to OCL fixation, which was secondary to a proud implant. The other secondary procedures included second-look arthroscopic surgery for pain after an injury postoperatively, planned anterior cruciate ligament reconstruction, staged medial patellofemoral ligament reconstruction, and manipulation under anesthesia for arthrofibrosis (n = 2). None of the 32 patients required a revision cartilage procedure at the time of final follow-up. Conclusion: The use of bioabsorbable implants in the adolescent knee appears to be a safe and efficacious treatment with good functional outcomes at long-term follow-up and a low revision rate. Additional long-term multisurgeon and multicenter trials with a larger cohort are needed to further elucidate the role of bioabsorbable fixation of an OCL in the adolescent knee.


2017 ◽  
Vol 45 (7) ◽  
pp. 1522-1528 ◽  
Author(s):  
Andrew D. Goodwillie ◽  
Sarav S. Shah ◽  
Malachy P. McHugh ◽  
Stephen J. Nicholas

Background: Many long-term studies have looked at outcomes after anterior cruciate ligament reconstruction (ACLR), but none have correlated long-term outcomes with postoperative laxity greater than 5 mm. It has been stated previously that more than 5 mm of postoperative graft laxity constituted a procedural failure. Purpose: To directly compare tight grafts (<3 mm) and loose grafts (>5 mm) to determine the effect of graft laxity, as measured by KT-1000 arthrometer, after ACLR on long-term clinical outcomes. Study Design: Cohort study; Level of evidence, 2. Methods: The study included 171 consecutive patients who had undergone transtibial bone–patellar tendon–bone ACLR between 1992 and 1998. At 6, 12, and 24 months postoperatively (the immediate postoperative period), patients were evaluated. Group A included patients with a maximal side-to-side (STS) difference in the immediate postoperative period of less than 3 mm (tight grafts), and group B included patients with a maximal STS difference of greater than 5 mm (loose grafts). Any patient with a history of ipsilateral or contralateral ACLR or ACL injury, meniscectomy, or cartilage restoration was excluded. Patients were prospectively followed to long-term follow-up, when a telephone interview was conducted regarding knee function and to document Lysholm, Tegner, Knee injury and Osteoarthritis Outcome Score (KOOS), and International Knee Documentation Committee (IKDC) subjective outcome scores. Results: Eighty-seven patients met inclusion criteria: 66 tight grafts (group A) and 21 loose grafts (group B). The mean ± SD time to follow-up was 16.3 ± 1.5 years in group A (n = 46) and 16.8 ± 1.3 years in group B (n = 15). Tegner ( P = .77), Lysholm ( P = .85), KOOS ( P = .96), and IKDC ( P = .42) were found to have no statistically significant difference between groups at long-term follow-up. Both Tegner and Lysholm scores significantly improved in tight and loose grafts in the immediate postoperative period as well as at long-term follow-up compared with preoperatively. There were 2 ACL revisions in group A and none in group B. Eleven of 46 patients (24%) in group A required subsequent procedures versus 1 of 15 patients (6.7%) in group B ( P = .146). Conclusion: Postoperative laxity of greater than 5 mm STS difference as measured by KT-1000 arthrometer does not appear to place patients at a worse clinical outcome at long-term follow-up, nor does it lead to significantly more subsequent procedures. In addition, transtibial ACLR can provide excellent clinical results at long-term follow-up.


Sign in / Sign up

Export Citation Format

Share Document