scholarly journals Handheld Multispectral Fluorescence Imaging System to Detect and Disinfect Surface Contamination

Sensors ◽  
2021 ◽  
Vol 21 (21) ◽  
pp. 7222
Author(s):  
Mitchell Sueker ◽  
Kristen Stromsodt ◽  
Hamed Taheri Gorji ◽  
Fartash Vasefi ◽  
Nadeem Khan ◽  
...  

Contamination inspection is an ongoing concern for food distributors, restaurant owners, caterers, and others who handle food. Food contamination must be prevented, and zero tolerance legal requirements and damage to the reputation of institutions or restaurants can be very costly. This paper introduces a new handheld fluorescence-based imaging system that can rapidly detect, disinfect, and document invisible organic residues and biofilms which may host pathogens. The contamination, sanitization inspection, and disinfection (CSI-D) system uses light at two fluorescence excitation wavelengths, ultraviolet C (UVC) at 275 nm and violet at 405 nm, for the detection of organic residues, including saliva and respiratory droplets. The 275 nm light is also utilized to disinfect pathogens commonly found within the contaminated residues. Efficacy testing of the neutralizing effects of the ultraviolet light was conducted for Aspergillus fumigatus, Streptococcus pneumoniae, and the influenza A virus (a fungus, a bacterium, and a virus, respectively, each commonly found in saliva and respiratory droplets). After the exposure to UVC light from the CSI-D, all three pathogens experienced deactivation (> 99.99%) in under ten seconds. Up to five-log reductions have also been shown within 10 s of UVC irradiation from the CSI-D system.

2019 ◽  
Vol 31 (2) ◽  
pp. 279-284 ◽  
Author(s):  
Ahmed Mansour ◽  
Toshiki Endo ◽  
Tomoo Inoue ◽  
Kenichi Sato ◽  
Hidenori Endo ◽  
...  

The authors report the case of a 78-year-old man with a craniocervical junction epidural arteriovenous fistula who presented with subarachnoid hemorrhage from a ruptured anterior spinal artery (ASA) aneurysm. Because endovascular embolization was difficult, a posterolateral approach was chosen and a novel endoscopic fluorescence imaging system was utilized to clip the aneurysm. The fluorescence imaging system provided clear and magnified views of the ventral spinal cord simultaneously with the endoscope-integrated indocyanine green videoangiography, which helped safely obliterate the ASA aneurysm. With the aid of this novel imaging system, surgeons can appreciate and manipulate complex vascular pathologies of the ventral spinal cord through a posterolateral approach, even when the lesion is closely related to the ASA.


2014 ◽  
Vol 106 (2) ◽  
pp. 400a
Author(s):  
Sohail Jahid ◽  
Alexander S. Dvornikov ◽  
Michelle Digman ◽  
Enrico Gratton

2013 ◽  
Vol 77 (5) ◽  
pp. AB553
Author(s):  
Hiroko Inomata ◽  
Naoto Tamai ◽  
Daisuke Ide ◽  
Tomohiko R. Ohya ◽  
Hiroyuki Aihara ◽  
...  

2006 ◽  
Vol 11 (1) ◽  
pp. 014007 ◽  
Author(s):  
Alec M. De Grand ◽  
Stephen J. Lomnes ◽  
Deborah S. Lee ◽  
Matthew Pietrzykowski ◽  
Shunsuke Ohnishi ◽  
...  

2019 ◽  
Vol 5 (1) ◽  
pp. 27-33 ◽  
Author(s):  
Masaki Imai ◽  
Makoto Yamashita ◽  
Yuko Sakai-Tagawa ◽  
Kiyoko Iwatsuki-Horimoto ◽  
Maki Kiso ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document