Faculty of 1000 evaluation for Comparison of the neutral and retracted shoulder positions for infraclavicular subclavian venous catheterization: a randomized, non-inferiority trial.

Author(s):  
Nikolaus Gravenstein ◽  
Felipe Urdaneta
JAMA ◽  
1966 ◽  
Vol 197 (8) ◽  
pp. 658-660 ◽  
Author(s):  
A. R. Hohn

1970 ◽  
Vol 3 (1) ◽  
pp. 27-34
Author(s):  
Lucas Tavares Dos Santos ◽  
Tânia Massini Evangelista

Introdução: A hérnia diafragmática congênita é a falha do fechamento embrionário do músculo diafragmático, resultando em um defeito de continuidade. Esta patologia pode ocorrer pela passagem de estruturas do abdome através de um defeito no diafragma, ou haver herniação parcial do estômago através do hiato esofágico, paralisia frênica com deslocamento do conteúdo abdominal para cima, mas sem herniação, e, eventração do diafragma. Casuística: Foi relatado um caso de hérnia diafragmática congênita, hérnia de Bochdalek, em um recém – nascido do sexo feminino, que nos ultra-sonografias da gestante apresentavam sem alterações. O diagnóstico da patologia foi feito apenas após a realização de raios-X de tórax e abdome para confirmar a posição do cateterismo umbilical venoso. Discussão/Conclusão: A apresentação clínica da hérnia de diafragmática congênita inclui desconforto respiratório moderado a grave com repercussão sistêmica. O diagnóstico, em cerca de 80% dos casos, é feito por ultrassom pré-natal. O tratamento proposto foi intubação endotraqueal com ventilação mecânica e programação para correção cirúrgica da hérnia. Após correção cirúrgica da patologia, a paciente permaneceu na unidade de terapia intensiva neonatal por 21 dias para acompanhamento de pós – operatório e intercorrências na evolução. Palavras-chave: hérnia diafragmática congênita, recém-nascido, hérnia de BochdalekABSTRACTIntroduction: Congenital diaphragmatic hernia is the failure of embryonic closure of the diaphragm, resulting in a lack of continuity. This condition can occur by passing structures of the abdomen through a defect in the diaphragm, or be part herniation of the stomach through the esophageal hiatus, phrenic paralysis with displacement of abdominal contents up but no herniation, and eventration of the diaphragm. Case Report: We report a case congenital diaphragmatic hernia, such as Bochdalek hernia, in a new - born female that in ultrasounds of pregnant women showed without change. The diagnosis of the disease was made only after conducting X-ray of the chest and abdomen to confirm the position of umbilical venous catheterization. Discussion/Conclusion: Clinical presentation of congenital diaphragmatic hernia includes moderate to severe respiratory distress with systemic repercussions. The diagnosis in about 80% of the cases is done by ultrasound prenatally. The proposed treatment was endotracheal intubation with mechanical ventilation and programming for surgical correction of the hernia. After surgical pathology, the patient remained in neonatal intensive care unit for 21 days to monitor post - operative complications and evolution.  Keywords: congenital diaphragmatic hernia, newborn, Bochdalek hernia 


1982 ◽  
Vol 16 (3) ◽  
pp. 521-523 ◽  
Author(s):  
Mark P. Bree ◽  
Nancy K. Mello ◽  
Kathy L. Harvey ◽  
Susan A. Webb

Author(s):  
Jessica M. Gonzalez-Vargas ◽  
Dailen C. Brown ◽  
Jason Z. Moore ◽  
David C. Han ◽  
Elizabeth H. Sinz ◽  
...  

The Dynamic Haptic Robotic Trainer (DHRT) was developed to minimize the up to 39% of adverse effects experienced by patients during Central Venous Catheterization (CVC) by standardizing CVC training, and provide automated assessments of performance. Specifically, this system was developed to replace manikin trainers that only simulate one patient anatomy and require a trained preceptor to evaluate the trainees’ performance. While the DHRT system provides automated feedback, the utility of this system with real-world scenarios and expertise has yet to be thoroughly investigated. Thus, the current study was developed to determine the validity of the current objective assessment metrics incorporated in the DHRT system through expert interviews. The main findings from this study are that experts do agree on perceptions of patient case difficulty, and that characterizations of patient case difficulty is based on anatomical characteristics, multiple needle insertions, and prior catheterization.


2005 ◽  
Vol 26 (1) ◽  
pp. 13-20 ◽  
Author(s):  
François L'Hériteau ◽  
Corinne Alberti ◽  
Yves Cohen ◽  
Gilles Troché ◽  
Pierre Moine ◽  
...  

AbstractObjectives:To evaluate nosocomial infection (NI) surveillance strategies in French ICUs and to identify similar patterns defining subsets within which comparisons can be made.Design:A questionnaire was sent to all French ICUs, and a random sample of nonresponders was interviewed.Participants:Three hundred ninety-five responder ICUs (69%) in France.Results:In 282 ICUs (71%), a dedicated ICU staff member was responsible for infection control activities. The microbiology laboratory was usually in the hospital (90%) and computerized (94%) but issued regular hospital microbiology records in only 48% of cases. Patients receiving mechanical ventilation, central venous catheterization, and urinary catheterization were 90%, 79%, and 60%, respectively. Patients were screened for carriage of mul-tidrug-resistant bacteria on admission and during the stay in 70% and 60% of ICUs, respectively, most often targeting MRSA. Quantitative cultures were used to diagnose ventilator-associated pneumonia (VAP) in 90% of ICUs, including distal specimens in 80% and bronchoscopy specimens in 60%. Quantitative central venous catheter (CVC)-segment cultures were used in 70% of ICUs. All CVCs were cultured routinely in 53% of the ICUs. Despite wide variations in infection control and surveillance strategies, multiple correspondence analysis identified 13 key points (4 structural variables and 9 variables concerning the diagnosis of VAP, the surveillance and diagnosis of catheter-related and urinary tract infections, and the mode of screening of MRSA carriers) that categorize the variability of French ICUs' approaches to NIs.Conclusion:This study revealed profound differences in N1 surveillance strategies across ICUs, indicating a need for caution when using N1 surveillance data for comparisons and benchmarking.


1987 ◽  
Vol 21 (4) ◽  
pp. 201A-201A
Author(s):  
Robert K Kanter ◽  
Jan M Gorton ◽  
Kathy Palmieri ◽  
Joy M Tompkins ◽  
Frank Smith ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document