Faculty Opinions recommendation of Estimating the number of pure chemical components in a mixture by X-ray absorption spectroscopy.

Author(s):  
James Penner-Hahn
2014 ◽  
Vol 21 (5) ◽  
pp. 1140-1147 ◽  
Author(s):  
Alain Manceau ◽  
Matthew Marcus ◽  
Thomas Lenoir

Principal component analysis (PCA) is a multivariate data analysis approach commonly used in X-ray absorption spectroscopy to estimate the number of pure compounds in multicomponent mixtures. This approach seeks to describe a large number of multicomponent spectra as weighted sums of a smaller number of component spectra. These component spectra are in turn considered to be linear combinations of the spectra from the actual species present in the system from which the experimental spectra were taken. The dimension of the experimental dataset is given by the number of meaningful abstract components, as estimated by the cascade or variance of the eigenvalues (EVs), the factor indicator function (IND), or the F-test on reduced EVs. It is shown on synthetic and real spectral mixtures that the performance of the IND and F-test critically depends on the amount of noise in the data, and may result in considerable underestimation or overestimation of the number of components even for a signal-to-noise (s/n) ratio of the order of 80 (σ = 20) in a XANES dataset. For a given s/n ratio, the accuracy of the component recovery from a random mixture depends on the size of the dataset and number of components, which is not known in advance, and deteriorates for larger datasets because the analysis picks up more noise components. The scree plot of the EVs for the components yields one or two values close to the significant number of components, but the result can be ambiguous and its uncertainty is unknown. A new estimator, NSS-stat, which includes the experimental error to XANES data analysis, is introduced and tested. It is shown that NSS-stat produces superior results compared with the three traditional forms of PCA-based component-number estimation. A graphical user-friendly interface for the calculation of EVs, IND, F-test and NSS-stat from a XANES dataset has been developed under LabVIEW for Windows and is supplied in the supporting information. Its possible application to EXAFS data is discussed, and several XANES and EXAFS datasets are also included for download.


1986 ◽  
Vol 47 (C8) ◽  
pp. C8-237-C8-242 ◽  
Author(s):  
B. S. CLAUSEN ◽  
B. LENGELER ◽  
B. S. RASMUSSEN ◽  
W. NIEMANN ◽  
H. TOPSØE

1986 ◽  
Vol 47 (C8) ◽  
pp. C8-149-C8-151
Author(s):  
F. W. LYTLE ◽  
R. B. GREEGOR ◽  
G. H. VIA ◽  
J. M. BROWN ◽  
G. MEITZNER

1986 ◽  
Vol 47 (C8) ◽  
pp. C8-1155-C8-1157
Author(s):  
E. C. THEIL ◽  
D. E. SAYERS ◽  
C. Y. YANG ◽  
A. FONTAINE ◽  
E. DARTYGE

1986 ◽  
Vol 47 (C8) ◽  
pp. C8-555-C8-561 ◽  
Author(s):  
S. SAIGO ◽  
H. OYANAGI ◽  
T. MATSUSHITA ◽  
H. HASHIMOTO ◽  
N. YOSHIDA ◽  
...  

2019 ◽  
Author(s):  
Jisue Moon ◽  
Carter Abney ◽  
Dmitriy Dolzhnikov ◽  
James M. Kurley ◽  
Kevin A. Beyer ◽  
...  

The local structure of dilute CrCl<sub>3</sub> in a molten MgCl<sub>2</sub>:KCl salt was investigated by <i>in situ</i> x-ray absorption spectroscopy (XAS) at temperatures from room temperature to 800<sup>o</sup>C. This constitutes the first experiment where dilute Cr speciation is explored in a molten chloride salt, ostensibly due to the compounding challenges arising from a low Cr concentration in a matrix of heavy absorbers at extreme temperatures. CrCl<sub>3</sub> was confirmed to be the stable species between 200 and 500<sup>o</sup>C, while mobility of metal ions at higher temperature (>700<sup>o</sup>C) prevented confirmation of the local structure.


Sign in / Sign up

Export Citation Format

Share Document