scholarly journals Obtenção e análise de espectros de energia para detectores de radiação com osciloscópio digital e software tipo planilha eletrônica / Obtaining and analysis of the energy spectra for radiation detectors with digital oscilloscope and worksheet software

2021 ◽  
Vol 7 (9) ◽  
pp. 91027-91040
Author(s):  
Silas Alexandre Gonçalves ◽  
Samuel Amorim Canazza ◽  
Fabio Eduardo Da Costa ◽  
Margarida Mizue Hamada
2015 ◽  
Vol 22 (5) ◽  
pp. 1190-1201 ◽  
Author(s):  
Leonardo Abbene ◽  
Gaetano Gerardi

Dead-time losses are well recognized and studied drawbacks in counting and spectroscopic systems. In this work the abilities on dead-time correction of a real-time digital pulse processing (DPP) system for high-rate high-resolution radiation measurements are presented. The DPP system, through a fast and slow analysis of the output waveform from radiation detectors, is able to perform multi-parameter analysis (arrival time, pulse width, pulse height, pulse shape,etc.) at high input counting rates (ICRs), allowing accurate counting loss corrections even for variable or transient radiations. The fast analysis is used to obtain both the ICR and energy spectra with high throughput, while the slow analysis is used to obtain high-resolution energy spectra. A complete characterization of the counting capabilities, through both theoretical and experimental approaches, was performed. The dead-time modeling, the throughput curves, the experimental time-interval distributions (TIDs) and the counting uncertainty of the recorded events of both the fast and the slow channels, measured with a planar CdTe (cadmium telluride) detector, will be presented. The throughput formula of a series of two types of dead-times is also derived. The results of dead-time corrections, performed through different methods, will be reported and discussed, pointing out the error on ICR estimation and the simplicity of the procedure. Accurate ICR estimations (nonlinearity < 0.5%) were performed by using the time widths and the TIDs (using 10 ns time bin width) of the detected pulses up to 2.2 Mcps. The digital system allows, after a simple parameter setting, different and sophisticated procedures for dead-time correction, traditionally implemented in complex/dedicated systems and time-consuming set-ups.


Author(s):  
I.M. Gazizov ◽  
◽  
I.A. Kaplunov ◽  
A.N. Nikiforova ◽  
A.A. Olnev ◽  
...  
Keyword(s):  

2018 ◽  
Vol 84 (12) ◽  
pp. 5-19
Author(s):  
D. N. Bock ◽  
V. A. Labusov

A review of publications regarding detection of non-metallic inclusions in metal alloys using optical emission spectrometry with single-spark spectrum registration is presented. The main advantage of the method - an extremely short time of measurement (~1 min) – makes it useful for the purposes of direct production control. A spark-induced impact on a non-metallic inclusion results in a sharp increase (flashes) in the intensities of spectral lines of the elements that comprise the inclusion because their content in the metal matrix is usually rather small. The intensity distribution of the spectral line of the element obtained from several thousand of single-spark spectra consists of two parts: i) the Gaussian function corresponding to the content of the element in a dissolved form, and ii) an asymmetric additive in the region of high intensity values ??attributed to inclusions. Their quantitative determination is based on the assumption that the intensity of the spectral line in the single-spark spectrum is proportional to the content of the element in the matter ablated by the spark. Thus, according to the calibration dependence constructed using samples with a certified total element content, it is possible not only to determine the proportions of the dissolved and undissolved element, but also the dimensions of the individual inclusions. However, determination of the sizes is limited to a range of 1 – 20 µm. Moreover, only Al-containing inclusions can be determined quantitatively nowadays. Difficulties occur both with elements hardly dissolved in steels (O, Ca, Mg, S), and with the elements which exhibit rather high content in the dissolved form (Si, Mn). It is also still impossible to determine carbides and nitrides in steels using C and N lines. The use of time-resolved spectrometry can reduce the detection limits for inclusions containing Si and, possibly, Mn. The use of the internal standard in determination of the inclusions can also lower the detection limits, but may distort the results. Substitution of photomultipliers by solid-state linear radiation detectors provided development of more reliable internal standard, based on the background value in the vicinity of the spectral line. Verification of the results is difficult in the lack of standard samples of composition of the inclusions. Future studies can expand the range of inclusions to be determined by this method.


Tellus ◽  
1981 ◽  
Vol 33 (1) ◽  
pp. 102-104 ◽  
Author(s):  
Tsing-Chang Chen ◽  
Joseph J. Tribbia

Tellus ◽  
1972 ◽  
Vol 24 (2) ◽  
pp. 161-163 ◽  
Author(s):  
Jacques C. J. Nihoul

Sign in / Sign up

Export Citation Format

Share Document