scholarly journals Fixed off Time Based Power-Factor Correction for AC-DC Converter

The conversion of A.C to D.C determines the distortion of the mains current A.C., which degrades the input power factor. The main reason for a poor power factor is the non-linear nature of the circuit. In this paper power factor is improved by using a basic boost converter and a control technique based on the fixed off time(FOT) approach .The traditional approach to the correction of the power factor in the boost converter is the continuous conduction mode with fixed frequency (FF-CCM) and the transition mode (TM) PWM (fixed connection time, variable frequency). In the first mode, the inductor operates in continuous conduction mode (CCM) and uses the average current-mode control mode; a complex technique involves a considerable number of components. The second method uses the more complex control technique of the peak current mode that makes the inductor work between continuous and discontinuous mode, which uses fewer components, unstable greater than 50% duty cycle and is more cost efficient. A third approach, the fixed off time (FOT) is gaining popularity which is conditionally stable for a duty cycle of over 50% and does not need compensation. The paper work carried out to use the power factor correction (PFC) based on DC-DC Flyback converter. To verify the design and operation of the circuit, the simulation is performed in PSIM .A prototype is developed and results are presented.

Author(s):  
MOH. ZAENAL EFENDI ◽  
DEWI KUSUMA WATI ◽  
LUCKY PRADIGTA SETIYA RAHARJA

ABSTRAKPeralatan elektronika umumnya memerlukan catu daya berupa sumber tegangan DC yang berasal dari sumber tegangan AC 220 V yang disearahkan menggunakan penyearah gelombang penuh. Pemasangan filter kapasitor pada sisi output penyearah menyebabkan bentuk gelombang arus masukan terdistorsi sehingga menimbulkan arus harmonisa yang mengakibatkan nilai faktor daya menjadi rendah. Artikel ini membahas mengenai paralel flyback konverter sebagai PFC (Power Factor Correction) pada lampu LED 36 V/60 W menggunakan algoritma fuzzy type-2. Flyback konverter pertama sebagai regulator tegangan DC bekerja dalam kondisi CCM (Continuous Conduction Mode). Flyback konverter kedua sebagai PFC bekerja dalam kondisi DCM (Discontinuous Conduction Mode) sehingga konverter bersifat resistif. Hasil simulasi menunjukkan bahwa paralel flyback konverter dapat memperbaiki faktor daya dari 0.597 menjadi 0.903 dan dapat menjaga tegangan keluaran konstan sebesar 36 V menggunakan algoritma fuzzy type-2 serta arus input yang dihasilkan memenuhi standar internasional hamonisa IEC61000-3-2 kelas C.Kata kunci: PFC, flyback konverter, IEC61000-3-2, lampu LED, fuzzy type-2 ABSTRACTElectronic equipment generally requires a DC voltage source that comes from a rectified 220 AC voltage source using full-wave rectifier. Installing capacitor filter on the output of rectifier makes the input current waveform becoming distorted that cause harmonic current which results in low power factor value. This article discusses parallel flyback converter as PFC (Power Factor Correction) on 36 V/60 W LED lamp using fuzzy type-2 algorithm. The first flyback converter as voltage dc regulator works in CCM (Continuous Conduction Mode). The second flyback converter as PFC works in DCM (Discontinuous Conduction Mode) to make the resistive converter. The simulation results shows the parallel flyback converter can improve the power factor from 0.597 to become 0.903 and can maintain a constant output voltage of 36 V using fuzzy type-2 algorithm and the input current meets the international harmonics standard of IEC61000-3-2 class C.Keywords: PFC, flyback converter, IEC61000-3-2, LED lamp, fuzzy type-2


Sign in / Sign up

Export Citation Format

Share Document